Vertical root fracture diagnosis in teeth with metallic posts: Impact of metal artifact reduction and sharpening filters.

IF 1.7 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Imaging Science in Dentistry Pub Date : 2024-06-01 Epub Date: 2024-04-02 DOI:10.5624/isd.20230233
Débora Costa Ruiz, Lucas P Lopes Rosado, Rocharles Cavalcante Fontenele, Amanda Farias-Gomes, Deborah Queiroz Freitas
{"title":"Vertical root fracture diagnosis in teeth with metallic posts: Impact of metal artifact reduction and sharpening filters.","authors":"Débora Costa Ruiz, Lucas P Lopes Rosado, Rocharles Cavalcante Fontenele, Amanda Farias-Gomes, Deborah Queiroz Freitas","doi":"10.5624/isd.20230233","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study examined the influence of a metal artifact reduction (MAR) tool, sharpening filters, and their combination on the diagnosis of vertical root fracture (VRF) in teeth with metallic posts using cone-beam computed tomography (CBCT).</p><p><strong>Materials and methods: </strong>Twenty single-rooted human premolars - 9 with VRF and 11 without - were individually placed in a human mandible. A metallic post composed of a cobalt-chromium alloy was inserted into the root canal of each tooth. CBCT scans were then acquired under the following parameters: 8 mA, a 5×5 cm field of view, a voxel size of 0.085 mm, 90 kVp, and with MAR either enabled or disabled. Five oral and maxillofacial radiologists independently evaluated the CBCT exams under each MAR mode and across 3 sharpening filter conditions: no filter, Sharpen 1×, and Sharpen 2×. The diagnostic performance was quantified by the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. These metrics were compared using 2-way analysis of variance with a significance level of α=5%. Intra- and inter-examiner agreement were assessed using the weighted kappa test.</p><p><strong>Results: </strong>Neither MAR nor the application of sharpening filters significantly impacted AUC or specificity (<i>P</i>>0.05). However, sensitivity increased when MAR was combined with Sharpen 1× and Sharpen 2× (<i>P</i>=0.015). The intra-examiner agreement ranged from fair to substantial (0.34-0.66), while the inter-examiner agreement ranged from fair to moderate (0.27-0.41).</p><p><strong>Conclusion: </strong>MAR in conjunction with sharpening filters improved VRF detection; therefore, their combined use is recommended in cases of suspected VRF.</p>","PeriodicalId":51714,"journal":{"name":"Imaging Science in Dentistry","volume":"54 2","pages":"139-145"},"PeriodicalIF":1.7000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11211027/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Imaging Science in Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5624/isd.20230233","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/2 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study examined the influence of a metal artifact reduction (MAR) tool, sharpening filters, and their combination on the diagnosis of vertical root fracture (VRF) in teeth with metallic posts using cone-beam computed tomography (CBCT).

Materials and methods: Twenty single-rooted human premolars - 9 with VRF and 11 without - were individually placed in a human mandible. A metallic post composed of a cobalt-chromium alloy was inserted into the root canal of each tooth. CBCT scans were then acquired under the following parameters: 8 mA, a 5×5 cm field of view, a voxel size of 0.085 mm, 90 kVp, and with MAR either enabled or disabled. Five oral and maxillofacial radiologists independently evaluated the CBCT exams under each MAR mode and across 3 sharpening filter conditions: no filter, Sharpen 1×, and Sharpen 2×. The diagnostic performance was quantified by the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. These metrics were compared using 2-way analysis of variance with a significance level of α=5%. Intra- and inter-examiner agreement were assessed using the weighted kappa test.

Results: Neither MAR nor the application of sharpening filters significantly impacted AUC or specificity (P>0.05). However, sensitivity increased when MAR was combined with Sharpen 1× and Sharpen 2× (P=0.015). The intra-examiner agreement ranged from fair to substantial (0.34-0.66), while the inter-examiner agreement ranged from fair to moderate (0.27-0.41).

Conclusion: MAR in conjunction with sharpening filters improved VRF detection; therefore, their combined use is recommended in cases of suspected VRF.

带金属支架牙齿的垂直根折诊断:减少金属伪影和锐化滤波器的影响。
目的:本研究利用锥形束计算机断层扫描(CBCT)技术,研究了金属伪影还原工具(MAR)、锐化滤波器及其组合对带有金属桩的牙齿垂直根折(VRF)诊断的影响:将 20 颗单根人类前臼齿(9 颗有 VRF,11 颗无 VRF)分别植入人类下颌骨。在每颗牙齿的根管内插入一个由钴铬合金组成的金属柱。然后在以下参数下采集 CBCT 扫描:8 mA、5×5 厘米视场、0.085 毫米体素大小、90 kVp,并启用或禁用 MAR。五名口腔颌面部放射科医生在每种 MAR 模式下和 3 种锐化滤镜条件(无滤镜、锐化 1 倍和锐化 2 倍)下对 CBCT 检查进行了独立评估。诊断性能通过接收者工作特征曲线下面积(AUC)、灵敏度和特异性进行量化。这些指标采用双向方差分析进行比较,显著性水平为 α=5%。使用加权卡帕检验对检查者内部和检查者之间的一致性进行评估:MAR和锐化滤波器的应用均未对AUC或特异性产生显著影响(P>0.05)。然而,当 MAR 与 Sharpen 1× 和 Sharpen 2× 结合使用时,灵敏度有所提高(P=0.015)。检查者内部的一致性从一般到相当(0.34-0.66)不等,而检查者之间的一致性从一般到中等(0.27-0.41)不等:结论:MAR 与锐化滤波器结合使用可提高 VRF 的检测率;因此,建议在怀疑有 VRF 的病例中将两者结合使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Imaging Science in Dentistry
Imaging Science in Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.90
自引率
11.10%
发文量
42
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信