Field Hip Stability Isometric Test (F-HipSIT): Reliability of Assessing the Hip Posterolateral Muscle Strength in Sports Settings.

IF 1.3 4区 医学 Q3 REHABILITATION
Journal of Sport Rehabilitation Pub Date : 2024-06-27 Print Date: 2024-08-01 DOI:10.1123/jsr.2023-0146
Felipe Xavier de Lima E Silva, João Breno de Araujo Ribeiro-Alvares, Lucas de Souza Roberti, Matheus Pitrez Mocellin, Bruno Manfredini Baroni
{"title":"Field Hip Stability Isometric Test (F-HipSIT): Reliability of Assessing the Hip Posterolateral Muscle Strength in Sports Settings.","authors":"Felipe Xavier de Lima E Silva, João Breno de Araujo Ribeiro-Alvares, Lucas de Souza Roberti, Matheus Pitrez Mocellin, Bruno Manfredini Baroni","doi":"10.1123/jsr.2023-0146","DOIUrl":null,"url":null,"abstract":"<p><strong>Context: </strong>The Hip Stability Isometric Test (HipSIT) is commonly employed in clinical settings for evaluating the hip posterolateral muscle strength. In this study, we introduced the \"Field Hip Stability Isometric Test\" (F-HipSIT) and assessed the intrarater and interrater reliability of this strength assessment specifically designed for sports settings.</p><p><strong>Design: </strong>Reliability study.</p><p><strong>Methods: </strong>Two independent raters (A and B) went to athletes' training facilities to conduct 2 sessions of F-HipSIT spaced at least 1 week apart. The average peak force value from 3 valid attempts of each leg was recorded and normalized by the participant's body mass for statistical analysis.</p><p><strong>Results: </strong>Thirty male and 30 female amateur athletes took part in this study. Rater A obtained similar values in the first (0.39 [0.05] and 0.44 [0.07] kg·f/kg) and second (0.39 [0.06] and 0.45 [0.07] kg·f/kg) testing days for men and women, respectively. Rater B also found similar values in the first (0.35 [0.06] and 0.42 [0.08] kg·f/kg) and second (0.36 [0.06] and 0.45 [0.08] kg·f/kg) testing days for men and women, respectively. Excellent intrarater intraclass correlation coefficient (ICC) values were found for men (ICC = .922) and women (ICC = .930), with coefficient of variation of 6% to 8% and minimal detectable change of 0.06 to 0.10 kg·f/kg. The F-HipSIT presented good interrater reliability for men (ICC = .857) and women (ICC = .868), with coefficient of variation of 5% and minimal detectable change of 0.05 to 0.06 kg·f/kg.</p><p><strong>Conclusion: </strong>The F-HipSIT intrarater and interrater reliability among male and female recreational athletes supports this field test as a quick and convenient screening tool to monitor hip posterolateral muscle strength in sports settings.</p>","PeriodicalId":50041,"journal":{"name":"Journal of Sport Rehabilitation","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Sport Rehabilitation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1123/jsr.2023-0146","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/1 0:00:00","PubModel":"Print","JCR":"Q3","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0

Abstract

Context: The Hip Stability Isometric Test (HipSIT) is commonly employed in clinical settings for evaluating the hip posterolateral muscle strength. In this study, we introduced the "Field Hip Stability Isometric Test" (F-HipSIT) and assessed the intrarater and interrater reliability of this strength assessment specifically designed for sports settings.

Design: Reliability study.

Methods: Two independent raters (A and B) went to athletes' training facilities to conduct 2 sessions of F-HipSIT spaced at least 1 week apart. The average peak force value from 3 valid attempts of each leg was recorded and normalized by the participant's body mass for statistical analysis.

Results: Thirty male and 30 female amateur athletes took part in this study. Rater A obtained similar values in the first (0.39 [0.05] and 0.44 [0.07] kg·f/kg) and second (0.39 [0.06] and 0.45 [0.07] kg·f/kg) testing days for men and women, respectively. Rater B also found similar values in the first (0.35 [0.06] and 0.42 [0.08] kg·f/kg) and second (0.36 [0.06] and 0.45 [0.08] kg·f/kg) testing days for men and women, respectively. Excellent intrarater intraclass correlation coefficient (ICC) values were found for men (ICC = .922) and women (ICC = .930), with coefficient of variation of 6% to 8% and minimal detectable change of 0.06 to 0.10 kg·f/kg. The F-HipSIT presented good interrater reliability for men (ICC = .857) and women (ICC = .868), with coefficient of variation of 5% and minimal detectable change of 0.05 to 0.06 kg·f/kg.

Conclusion: The F-HipSIT intrarater and interrater reliability among male and female recreational athletes supports this field test as a quick and convenient screening tool to monitor hip posterolateral muscle strength in sports settings.

现场髋关节稳定性等长测试(F-HipSIT):在运动环境中评估髋关节后外侧肌肉力量的可靠性。
背景:髋关节稳定性等长测试(HipSIT)是临床上评估髋关节后外侧肌肉力量的常用方法。在本研究中,我们引入了 "野外髋关节稳定等长测试"(F-HipSIT),并评估了这种专为运动环境设计的力量评估方法的内部和内部可靠性:可靠性研究:两名独立评分员(A 和 B)前往运动员的训练场地进行两次 F-HipSIT 测试,每次测试间隔至少一周。记录每条腿 3 次有效尝试的平均峰值力值,并根据参与者的体重进行归一化统计分析:30 名男性和 30 名女性业余运动员参加了这项研究。测评员 A 在第一个测试日(0.39 [0.05] 和 0.44 [0.07] kg-f/kg)和第二个测试日(0.39 [0.06] 和 0.45 [0.07] kg-f/kg)分别获得了相似的男性和女性测评值。测评人 B 也发现,男性和女性在第一个测试日(0.35 [0.06] 和 0.42 [0.08] kg-f/kg)和第二个测试日(0.36 [0.06] 和 0.45 [0.08] kg-f/kg)的数值相似。男性(ICC = .922)和女性(ICC = .930)的类内相关系数(ICC)值极佳,变异系数在 6% 至 8% 之间,最小可检测变化为 0.06 至 0.10 kg-f/kg。F-HipSIT在男性(ICC = .857)和女性(ICC = .868)之间具有良好的互测可靠性,变异系数为5%,可检测到的最小变化为0.05至0.06 kg-f/kg:结论:F-HipSIT 在男性和女性休闲运动员中的内部和相互之间的可靠性证明,该现场测试是在运动环境中监测髋关节后外侧肌肉力量的一种快速、方便的筛查工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Sport Rehabilitation
Journal of Sport Rehabilitation 医学-康复医学
CiteScore
3.20
自引率
5.90%
发文量
143
审稿时长
>12 weeks
期刊介绍: The Journal of Sport Rehabilitation (JSR) is your source for the latest peer-reviewed research in the field of sport rehabilitation. All members of the sports-medicine team will benefit from the wealth of important information in each issue. JSR is completely devoted to the rehabilitation of sport and exercise injuries, regardless of the age, gender, sport ability, level of fitness, or health status of the participant. JSR publishes peer-reviewed original research, systematic reviews/meta-analyses, critically appraised topics (CATs), case studies/series, and technical reports that directly affect the management and rehabilitation of injuries incurred during sport-related activities, irrespective of the individual’s age, gender, sport ability, level of fitness, or health status. The journal is intended to provide an international, multidisciplinary forum to serve the needs of all members of the sports medicine team, including athletic trainers/therapists, sport physical therapists/physiotherapists, sports medicine physicians, and other health care and medical professionals.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信