Efficacy of 18FDG-PET/CT in Detecting Synchronous Malignancies in Patients With Head and Neck Cancer: A Systematic Review and Meta-analysis.

IF 2.6 3区 医学 Q1 OTORHINOLARYNGOLOGY
Otolaryngology- Head and Neck Surgery Pub Date : 2024-12-01 Epub Date: 2024-06-29 DOI:10.1002/ohn.879
Soroush Ershadifar, Jordan Larsson, Kurtis Young, Marianne Abouyared, Arnaud Bewley, Andrew C Birkeland
{"title":"Efficacy of <sup>18</sup>FDG-PET/CT in Detecting Synchronous Malignancies in Patients With Head and Neck Cancer: A Systematic Review and Meta-analysis.","authors":"Soroush Ershadifar, Jordan Larsson, Kurtis Young, Marianne Abouyared, Arnaud Bewley, Andrew C Birkeland","doi":"10.1002/ohn.879","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To assess the diagnostic accuracy of fluorine-18 fluorodeoxyglucose positron emission tomography and computed tomography (<sup>18</sup>FDG-PET/CT) in detecting second primary malignancies (SPMs) in patients with treatment naïve head and neck squamous cell carcinoma (HNSCC).</p><p><strong>Data sources: </strong>Medline, Embase, Cochrane Library, and Scopus searched from 1946 to December 2022.</p><p><strong>Review methods: </strong>Studies reporting the performance of <sup>18</sup>FDG-PET/CT in patients with treatment-naïve, index HNSCC for detection of SPMs were included. The reference standard was histopathology, clinical follow-up over the duration of study, and other imaging modalities. Multiple investigators completed depth full-text analysis. Preferred Reporting Items for Systematic Reviews and Meta-analysis guidelines were followed. Methodologic and diagnostic accuracy data were abstracted independently by multiple investigators. Risk of bias assessment was conducted using the Quality Assessment of Diagnostic Accuracy Studies tool independently. Bivariate random-effects model meta-analysis and multivariable meta-regression modeling were used.</p><p><strong>Results: </strong>Seventeen studies examining 4624 patients with a total of 475 SPMs were included in the final analysis. Eleven studies were found to be at low risk for bias, while the rest were in the high-risk category. <sup>18</sup>FDG-PET/CT demonstrated pooled sensitivity and specificity of 0.73 (95% confidence interval [CI]: 0.49-0.88) and 0.99 (95% CI: 0.98-1.00) in detecting SPMs. Further subsite analysis revealed varied diagnostic performance across different anatomical regions, with sensitivity and specificity of esophageal SPMs being 0.47 (0.30-0.64) and 0.99 (0.98-1.00), and sensitivity and specificity of 0.86 (0.73-0.94) and 0.99 (0.98-1.00) for head and neck SPMs. Finally, this imaging modality showed sensitivity and specificity of 0.92 (0.84-0.96) and 0.99 (0.98-1.00) for lung SPMs.</p><p><strong>Conclusion: </strong>The findings of this study suggest varied accuracy of <sup>18</sup>FDG-PET/CT in detecting SPMs during initial workup for HNSCC, highlighting the importance of screening modalities such as esophagoscopy in high-risk patients.</p>","PeriodicalId":19707,"journal":{"name":"Otolaryngology- Head and Neck Surgery","volume":" ","pages":"1639-1649"},"PeriodicalIF":2.6000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Otolaryngology- Head and Neck Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/ohn.879","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/29 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To assess the diagnostic accuracy of fluorine-18 fluorodeoxyglucose positron emission tomography and computed tomography (18FDG-PET/CT) in detecting second primary malignancies (SPMs) in patients with treatment naïve head and neck squamous cell carcinoma (HNSCC).

Data sources: Medline, Embase, Cochrane Library, and Scopus searched from 1946 to December 2022.

Review methods: Studies reporting the performance of 18FDG-PET/CT in patients with treatment-naïve, index HNSCC for detection of SPMs were included. The reference standard was histopathology, clinical follow-up over the duration of study, and other imaging modalities. Multiple investigators completed depth full-text analysis. Preferred Reporting Items for Systematic Reviews and Meta-analysis guidelines were followed. Methodologic and diagnostic accuracy data were abstracted independently by multiple investigators. Risk of bias assessment was conducted using the Quality Assessment of Diagnostic Accuracy Studies tool independently. Bivariate random-effects model meta-analysis and multivariable meta-regression modeling were used.

Results: Seventeen studies examining 4624 patients with a total of 475 SPMs were included in the final analysis. Eleven studies were found to be at low risk for bias, while the rest were in the high-risk category. 18FDG-PET/CT demonstrated pooled sensitivity and specificity of 0.73 (95% confidence interval [CI]: 0.49-0.88) and 0.99 (95% CI: 0.98-1.00) in detecting SPMs. Further subsite analysis revealed varied diagnostic performance across different anatomical regions, with sensitivity and specificity of esophageal SPMs being 0.47 (0.30-0.64) and 0.99 (0.98-1.00), and sensitivity and specificity of 0.86 (0.73-0.94) and 0.99 (0.98-1.00) for head and neck SPMs. Finally, this imaging modality showed sensitivity and specificity of 0.92 (0.84-0.96) and 0.99 (0.98-1.00) for lung SPMs.

Conclusion: The findings of this study suggest varied accuracy of 18FDG-PET/CT in detecting SPMs during initial workup for HNSCC, highlighting the importance of screening modalities such as esophagoscopy in high-risk patients.

18FDG-PET/CT 检测头颈癌患者同步恶性肿瘤的有效性:系统综述与元分析》。
目的评估氟-18氟脱氧葡萄糖正电子发射断层扫描和计算机断层扫描(18FDG-PET/CT)在检测头颈部鳞状细胞癌(HNSCC)患者中第二原发性恶性肿瘤(SPM)的诊断准确性:Medline、Embase、Cochrane Library和Scopus的检索时间为1946年至2022年12月:综述方法:纳入报告18FDG-PET/CT在治疗无效的指标性HNSCC患者中检测SPM效果的研究。参考标准为组织病理学、研究期间的临床随访以及其他成像模式。多名研究者完成了深度全文分析。遵循《系统综述和荟萃分析首选报告项目》指南。方法学和诊断准确性数据由多名研究者独立摘录。使用诊断准确性研究质量评估工具独立进行偏倚风险评估。采用双变量随机效应模型荟萃分析和多变量荟萃回归模型:最终分析共纳入了 17 项研究,共对 4624 名患者进行了 475 次 SPM 检查。其中有 11 项研究的偏倚风险较低,而其他研究的偏倚风险较高。18FDG-PET/CT在检测SPM方面的总体敏感性和特异性分别为0.73(95% 置信区间[CI]:0.49-0.88)和0.99(95% CI:0.98-1.00)。进一步的亚部位分析显示,不同解剖区域的诊断性能各不相同,食管SPM的敏感性和特异性分别为0.47(0.30-0.64)和0.99(0.98-1.00),头颈部SPM的敏感性和特异性分别为0.86(0.73-0.94)和0.99(0.98-1.00)。最后,该成像模式对肺部 SPM 的敏感性和特异性分别为 0.92(0.84-0.96)和 0.99(0.98-1.00):本研究的结果表明,18FDG-PET/CT 在 HNSCC 初步检查中检测 SPM 的准确性存在差异,这凸显了食管镜检查等筛查方式对高危患者的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Otolaryngology- Head and Neck Surgery
Otolaryngology- Head and Neck Surgery 医学-耳鼻喉科学
CiteScore
6.70
自引率
2.90%
发文量
250
审稿时长
2-4 weeks
期刊介绍: Otolaryngology–Head and Neck Surgery (OTO-HNS) is the official peer-reviewed publication of the American Academy of Otolaryngology–Head and Neck Surgery Foundation. The mission of Otolaryngology–Head and Neck Surgery is to publish contemporary, ethical, clinically relevant information in otolaryngology, head and neck surgery (ear, nose, throat, head, and neck disorders) that can be used by otolaryngologists, clinicians, scientists, and specialists to improve patient care and public health.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信