Runhan Zhao, Ningdao Li, Jun Zhang, Xiaoji Luo, Xifeng Zhang
{"title":"Endoscopic double line suture repair technique for repairing Iatrogenic dural tear: a technical case report.","authors":"Runhan Zhao, Ningdao Li, Jun Zhang, Xiaoji Luo, Xifeng Zhang","doi":"10.1007/s00586-024-08383-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Introducing a suture repair technology, endoscopic double line suture repair technique, for iatrogenic dural injury during Percutaneous Endoscopic Lumbar Discectomy (PELD) surgery.</p><p><strong>Methods: </strong>A patient with dural injury and cauda equina herniation during PELD surgery was treated with endoscopic double line suture repair technique.</p><p><strong>Results: </strong>A patient with dural injury and cauda equina nerve herniation during PELD surgery was successfully treated using double-line suture technique. After the repair, no obvious cerebrospinal fluid leakage and cauda equina nerve re-herniation was seen. During the postoperative observation period, the wound healed well and there were no complications related to cerebrospinal leakage. During the follow-up period (1 year), the patient reported significant symptom relief and no complications.</p><p><strong>Conclusion: </strong>This novel dural repair technology is safe and effective and can be used to treat dural injuries during PELD surgery.</p>","PeriodicalId":12323,"journal":{"name":"European Spine Journal","volume":" ","pages":"4397-4403"},"PeriodicalIF":2.6000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Spine Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00586-024-08383-7","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/27 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: Introducing a suture repair technology, endoscopic double line suture repair technique, for iatrogenic dural injury during Percutaneous Endoscopic Lumbar Discectomy (PELD) surgery.
Methods: A patient with dural injury and cauda equina herniation during PELD surgery was treated with endoscopic double line suture repair technique.
Results: A patient with dural injury and cauda equina nerve herniation during PELD surgery was successfully treated using double-line suture technique. After the repair, no obvious cerebrospinal fluid leakage and cauda equina nerve re-herniation was seen. During the postoperative observation period, the wound healed well and there were no complications related to cerebrospinal leakage. During the follow-up period (1 year), the patient reported significant symptom relief and no complications.
Conclusion: This novel dural repair technology is safe and effective and can be used to treat dural injuries during PELD surgery.
期刊介绍:
"European Spine Journal" is a publication founded in response to the increasing trend toward specialization in spinal surgery and spinal pathology in general. The Journal is devoted to all spine related disciplines, including functional and surgical anatomy of the spine, biomechanics and pathophysiology, diagnostic procedures, and neurology, surgery and outcomes. The aim of "European Spine Journal" is to support the further development of highly innovative spine treatments including but not restricted to surgery and to provide an integrated and balanced view of diagnostic, research and treatment procedures as well as outcomes that will enhance effective collaboration among specialists worldwide. The “European Spine Journal” also participates in education by means of videos, interactive meetings and the endorsement of educative efforts.
Official publication of EUROSPINE, The Spine Society of Europe