Mapping of Capsular Side Effects by using Intraoperative Motor-Evoked Potentials during Asleep Deep Brain Stimulation Surgery of the Subthalamic Nucleus for Parkinson's Disease.
Petar Antoan Karazapryanov, Kaloyan Rumenov Gabrovski, Yoana Milenova, Velislav Kirilov Pavlov, Alexander Karameshev, Maria Damianova, Stanimir Sirakov, Krasimir Minkin
{"title":"Mapping of Capsular Side Effects by using Intraoperative Motor-Evoked Potentials during Asleep Deep Brain Stimulation Surgery of the Subthalamic Nucleus for Parkinson's Disease.","authors":"Petar Antoan Karazapryanov, Kaloyan Rumenov Gabrovski, Yoana Milenova, Velislav Kirilov Pavlov, Alexander Karameshev, Maria Damianova, Stanimir Sirakov, Krasimir Minkin","doi":"10.1159/000539433","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The aim of this study was to present a novel technique for subthalamic nucleus (STN) deep brain stimulation (DBS) implantation under general anesthesia by using intraoperative motor-evoked potentials (MEPs) through direct lead stimulation and determining their correlation to the thresholds of postoperative stimulation-induced side effects.</p><p><strong>Methods: </strong>This study included 22 consecutive patients with advanced Parkinson's disease who underwent surgery in our institution between January 2021 and September 2023. All patients underwent bilateral implantation in the STN (44 leads) under general anesthesia without microelectrode recordings (MERs) by using MEPs with electrostimulation directly through the DBS lead. No cortical stimulation was performed during this process. Intraoperative fluoroscopic guidance and immediate postoperative computed tomography were used to verify the electrode's position. The lowest MEP thresholds were recorded and were correlated to the postoperative stimulation-induced side-effect threshold. The predictive values of the MEPs were analyzed. Five DBS leads were repositioned intraoperatively due to the MEP results.</p><p><strong>Results: </strong>A moderately strong positive correlation was found between the MEP threshold and the capsular side-effect threshold (RS = 0.425, 95% CI, 0.17-0.67, p = 0.004). The highest sensitivity and specificity for predicting a side-effect threshold of 5 mA were found to be at 2.4 mA MEP threshold (sensitivity 97%, specificity 87.5%, positive predictive value 97%, and negative predictive value 87.5%). We also found high sensitivity and specificity (100%) at 1.15 mA MEP threshold and 3 mA side-effect threshold. Out of the total 44 leads, 5 (11.3%) leads were repositioned intraoperatively due to MEP thresholds lower than 1 mA (4 leads) or higher than 5 mA (1 lead). The mean accuracy on postoperative CT was 1.05 mm, and there were no postoperative side-effects under 2.8 mA.</p><p><strong>Conclusion: </strong>Intraoperative MEPs with electrostimulation directly through the contacts of the DBS lead correlate with the stimulation-induced capsular side effects. The lead reposition based on intraoperative MEP may enlarge the therapeutic window of DBS stimulation.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000539433","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/21 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: The aim of this study was to present a novel technique for subthalamic nucleus (STN) deep brain stimulation (DBS) implantation under general anesthesia by using intraoperative motor-evoked potentials (MEPs) through direct lead stimulation and determining their correlation to the thresholds of postoperative stimulation-induced side effects.
Methods: This study included 22 consecutive patients with advanced Parkinson's disease who underwent surgery in our institution between January 2021 and September 2023. All patients underwent bilateral implantation in the STN (44 leads) under general anesthesia without microelectrode recordings (MERs) by using MEPs with electrostimulation directly through the DBS lead. No cortical stimulation was performed during this process. Intraoperative fluoroscopic guidance and immediate postoperative computed tomography were used to verify the electrode's position. The lowest MEP thresholds were recorded and were correlated to the postoperative stimulation-induced side-effect threshold. The predictive values of the MEPs were analyzed. Five DBS leads were repositioned intraoperatively due to the MEP results.
Results: A moderately strong positive correlation was found between the MEP threshold and the capsular side-effect threshold (RS = 0.425, 95% CI, 0.17-0.67, p = 0.004). The highest sensitivity and specificity for predicting a side-effect threshold of 5 mA were found to be at 2.4 mA MEP threshold (sensitivity 97%, specificity 87.5%, positive predictive value 97%, and negative predictive value 87.5%). We also found high sensitivity and specificity (100%) at 1.15 mA MEP threshold and 3 mA side-effect threshold. Out of the total 44 leads, 5 (11.3%) leads were repositioned intraoperatively due to MEP thresholds lower than 1 mA (4 leads) or higher than 5 mA (1 lead). The mean accuracy on postoperative CT was 1.05 mm, and there were no postoperative side-effects under 2.8 mA.
Conclusion: Intraoperative MEPs with electrostimulation directly through the contacts of the DBS lead correlate with the stimulation-induced capsular side effects. The lead reposition based on intraoperative MEP may enlarge the therapeutic window of DBS stimulation.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.