Lucimere Bohn, Jessica Rial-Vázquez, Iván Nine, María Rúa-Alonso, Juan Fariñas, Manuel Avelino Giráldez-García, Jorge Mota, Eliseo Iglesias-Soler
{"title":"Arterial stiffness assessment by pulse wave velocity in postmenopausal women: comparison between noninvasive devices.","authors":"Lucimere Bohn, Jessica Rial-Vázquez, Iván Nine, María Rúa-Alonso, Juan Fariñas, Manuel Avelino Giráldez-García, Jorge Mota, Eliseo Iglesias-Soler","doi":"10.1097/GME.0000000000002383","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study aimed to ascertain the accuracy of measure arterial stiffness using the HUAWEI GT 3 Pro smartwatch and pOpmètre device against the SphygmoCor (algorithms: intersect tangent and maximum of the second derivate).</p><p><strong>Methods: </strong>Twenty-three physically active postmenopausal women (age: 58.9 ± 3.2 years; body mass index: 26.3 ± 4.8 kg/m 2 ) were recruited. Carotid-femoral pulse wave velocity, finger-toe pulse wave velocity, and wrist-finger pulse wave velocity were obtained using SphygmoCor, pOpmètre and HUAWEI GT 3 Pro devices in a randomized order. Additionally, the pulse mean carotid-femoral and finger-toe pulse transit time was registered for SphygmoCor and pOpmètre, respectively.</p><p><strong>Results: </strong>Lower values of pulse wave velocity were recorded by HUAWEI in comparison with SphygmoCor with both algorithms, whereas no significant differences were detected between SphygmoCor and pOpmètre results. Pulse wave velocity values from SphygmoCor were positively correlated with pOpmètre results ( r = 0.464 and r = 0.451 using intersect tangent and second derivative algorithms), whereas this was not the case with those obtained from HUAWEI. Coefficients of bias of Lin's concordance coefficients close to 1 (0.832 and 0.831 for intersect tangent and second derivative algorithm, respectively) and mean bias close to 0 from Bland-Altman analysis suggested an acceptable agreement between pulse wave velocity obtained from SphygmoCor and pOpmètre.</p><p><strong>Conclusions: </strong>Our results suggest an acceptable concordance of pulse wave velocity values recoded by SphygmoCor and pOpmètre, whereas this was not the case for data obtained from HUAWEI GT 3 Pro smartwatch. Therefore, the pOpmètre may be a viable alternative for assessing arterial stiffness, but measurement via the smartwatch device cannot be recommended.</p>","PeriodicalId":18435,"journal":{"name":"Menopause: The Journal of The North American Menopause Society","volume":" ","pages":"709-715"},"PeriodicalIF":2.8000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Menopause: The Journal of The North American Menopause Society","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/GME.0000000000002383","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/25 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: This study aimed to ascertain the accuracy of measure arterial stiffness using the HUAWEI GT 3 Pro smartwatch and pOpmètre device against the SphygmoCor (algorithms: intersect tangent and maximum of the second derivate).
Methods: Twenty-three physically active postmenopausal women (age: 58.9 ± 3.2 years; body mass index: 26.3 ± 4.8 kg/m 2 ) were recruited. Carotid-femoral pulse wave velocity, finger-toe pulse wave velocity, and wrist-finger pulse wave velocity were obtained using SphygmoCor, pOpmètre and HUAWEI GT 3 Pro devices in a randomized order. Additionally, the pulse mean carotid-femoral and finger-toe pulse transit time was registered for SphygmoCor and pOpmètre, respectively.
Results: Lower values of pulse wave velocity were recorded by HUAWEI in comparison with SphygmoCor with both algorithms, whereas no significant differences were detected between SphygmoCor and pOpmètre results. Pulse wave velocity values from SphygmoCor were positively correlated with pOpmètre results ( r = 0.464 and r = 0.451 using intersect tangent and second derivative algorithms), whereas this was not the case with those obtained from HUAWEI. Coefficients of bias of Lin's concordance coefficients close to 1 (0.832 and 0.831 for intersect tangent and second derivative algorithm, respectively) and mean bias close to 0 from Bland-Altman analysis suggested an acceptable agreement between pulse wave velocity obtained from SphygmoCor and pOpmètre.
Conclusions: Our results suggest an acceptable concordance of pulse wave velocity values recoded by SphygmoCor and pOpmètre, whereas this was not the case for data obtained from HUAWEI GT 3 Pro smartwatch. Therefore, the pOpmètre may be a viable alternative for assessing arterial stiffness, but measurement via the smartwatch device cannot be recommended.
期刊介绍:
Menopause, published monthly, provides a forum for new research, applied basic science, and clinical guidelines on all aspects of menopause. The scope and usefulness of the journal extend beyond gynecology, encompassing many varied biomedical areas, including internal medicine, family practice, medical subspecialties such as cardiology and geriatrics, epidemiology, pathology, sociology, psychology, anthropology, and pharmacology. This forum is essential to help integrate these areas, highlight needs for future research, and enhance health care.