Biomechanical analysis of single and multi-level artificial disc replacement (ADR) in cervical spine using multi-scale loadings: A finite element study.

IF 1.4 4区 医学 Q4 ENGINEERING, BIOMEDICAL
Ram Kumar, Amit Kumar, Shabanam Kumari
{"title":"Biomechanical analysis of single and multi-level artificial disc replacement (ADR) in cervical spine using multi-scale loadings: A finite element study.","authors":"Ram Kumar, Amit Kumar, Shabanam Kumari","doi":"10.1177/03913988241259969","DOIUrl":null,"url":null,"abstract":"<p><p>Artificial disc replacement (ADR) is a clinical procedure used to diagnose cervical degenerative disc disease, preserving range of motion (ROM) at the fixation level and preventing adjacent segment degeneration (ASD). This study analyzed the biomechanics of ADR by examining range of motion (ROM), stress levels in bone and implants, and strain in the bone-implant interface using multi-scale loadings. The study focused on single- and double-level patients across various loading scales during physiological motions within the cervical spine. Results showed increased ROM in single-level and double-level fixations during physiological loadings, while ROM decreased at the adjacent level of fixation with the intact cervical spine model. The Prodisc-Implant metal endplate experienced a maximum von Mises stress of 432 MPa during axial rotation, confirming the long durability and biomechanical performance of the bone-implant interface.</p>","PeriodicalId":13932,"journal":{"name":"International Journal of Artificial Organs","volume":" ","pages":"411-417"},"PeriodicalIF":1.4000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/03913988241259969","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/21 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Artificial disc replacement (ADR) is a clinical procedure used to diagnose cervical degenerative disc disease, preserving range of motion (ROM) at the fixation level and preventing adjacent segment degeneration (ASD). This study analyzed the biomechanics of ADR by examining range of motion (ROM), stress levels in bone and implants, and strain in the bone-implant interface using multi-scale loadings. The study focused on single- and double-level patients across various loading scales during physiological motions within the cervical spine. Results showed increased ROM in single-level and double-level fixations during physiological loadings, while ROM decreased at the adjacent level of fixation with the intact cervical spine model. The Prodisc-Implant metal endplate experienced a maximum von Mises stress of 432 MPa during axial rotation, confirming the long durability and biomechanical performance of the bone-implant interface.

使用多尺度载荷对颈椎单层和多层人工椎间盘置换术(ADR)进行生物力学分析:有限元研究。
人工椎间盘置换术(ADR)是一种用于诊断颈椎间盘退行性病变的临床手术,可保持固定水平的活动范围(ROM)并防止邻近节段退变(ASD)。本研究分析了 ADR 的生物力学,使用多尺度加载法检测了活动范围 (ROM)、骨和植入物的应力水平以及骨-植入物界面的应变。研究重点是单层和双层患者在颈椎生理运动过程中的各种加载尺度。结果表明,在生理负荷期间,单层和双层固定的 ROM 均有所增加,而在完整颈椎模型中,相邻固定层的 ROM 则有所减少。Prodisc-Implant 金属内板在轴向旋转时的最大 von Mises 应力为 432 兆帕,证实了骨-植入物界面的长期耐用性和生物力学性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Artificial Organs
International Journal of Artificial Organs 医学-工程:生物医学
CiteScore
3.40
自引率
5.90%
发文量
92
审稿时长
3 months
期刊介绍: The International Journal of Artificial Organs (IJAO) publishes peer-reviewed research and clinical, experimental and theoretical, contributions to the field of artificial, bioartificial and tissue-engineered organs. The mission of the IJAO is to foster the development and optimization of artificial, bioartificial and tissue-engineered organs, for implantation or use in procedures, to treat functional deficits of all human tissues and organs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信