Effects of different polishing procedures on the color stability of recent resin composites.

IF 0.9 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
American journal of dentistry Pub Date : 2024-06-01
Esra Özyurt, Aliye T Akçağlar, Ekin G Uysal Uzel
{"title":"Effects of different polishing procedures on the color stability of recent resin composites.","authors":"Esra Özyurt, Aliye T Akçağlar, Ekin G Uysal Uzel","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate different polishing methods' effects on the color stability of recent resin composites.</p><p><strong>Methods: </strong>160 samples for color stability evaluation and 40 samples for the degree of conversion evaluation were prepared with four different resin composites [Harmonize (H), Filtek Universal (F), Omnichroma (O), Essentia Universal (E)] and light cured. For color stability evaluation, samples prepared from each resin composite were divided into four groups: three polishing procedures and a control group. The ΔE₀₀ was calculated between initial, and after immersion in coffee solution for 12 days. The degree of conversion was evaluated with Fourier Transform Infrared Spectroscopy. The statistical analysis of ΔE₀₀ values was made with the two-way ANOVA, Tukey HSD, and Tamhane's T2 tests. One-way ANOVA and Tukey HSD tests were used to compare the degree of conversion values (P< 0.05).</p><p><strong>Results: </strong>In all composite groups, mylar (control) groups had the highest ΔE₀₀, and no differences between other polishing procedures. According to the polishing procedures, Omnichroma showed the highest ΔE₀₀ values (on mylar groups O vs F, P< 0.001; O vs H, P< 0.001; O vs E, P< 0.001). There was a significant difference between the composite groups in terms of the degree of monomer conversion (P< 0.05). Omnichroma showed, significantly, the highest discoloration.</p><p><strong>Clinical significance: </strong>Different polishing procedures showed effective performance on current composite surfaces. Omnichroma resin composite showed higher color change than composites with similar properties.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of dentistry","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate different polishing methods' effects on the color stability of recent resin composites.

Methods: 160 samples for color stability evaluation and 40 samples for the degree of conversion evaluation were prepared with four different resin composites [Harmonize (H), Filtek Universal (F), Omnichroma (O), Essentia Universal (E)] and light cured. For color stability evaluation, samples prepared from each resin composite were divided into four groups: three polishing procedures and a control group. The ΔE₀₀ was calculated between initial, and after immersion in coffee solution for 12 days. The degree of conversion was evaluated with Fourier Transform Infrared Spectroscopy. The statistical analysis of ΔE₀₀ values was made with the two-way ANOVA, Tukey HSD, and Tamhane's T2 tests. One-way ANOVA and Tukey HSD tests were used to compare the degree of conversion values (P< 0.05).

Results: In all composite groups, mylar (control) groups had the highest ΔE₀₀, and no differences between other polishing procedures. According to the polishing procedures, Omnichroma showed the highest ΔE₀₀ values (on mylar groups O vs F, P< 0.001; O vs H, P< 0.001; O vs E, P< 0.001). There was a significant difference between the composite groups in terms of the degree of monomer conversion (P< 0.05). Omnichroma showed, significantly, the highest discoloration.

Clinical significance: Different polishing procedures showed effective performance on current composite surfaces. Omnichroma resin composite showed higher color change than composites with similar properties.

不同抛光程序对近期树脂复合材料颜色稳定性的影响。
方法:用四种不同的树脂复合材料[Harmonize (H)、Filtek Universal (F)、Omnichroma (O)、Essentia Universal (E)]制备 160 个用于颜色稳定性评价的样品和 40 个用于转换度评价的样品,并进行光固化。为了评估颜色稳定性,将每种树脂复合材料制备的样品分为四组:三道抛光程序和一个对照组。ΔE₀₀是在初始和在咖啡溶液中浸泡 12 天后计算得出的。傅立叶变换红外光谱法评估了转化程度。ΔE₀₀值的统计分析采用双向方差分析、Tukey HSD 和 Tamhane's T2 检验。单因素方差分析和 Tukey HSD 检验用于比较转换值的程度(P< 0.05):在所有复合材料组中,麦拉纸组(对照组)的ΔE₀₀最高,其他抛光程序之间没有差异。根据抛光程序的不同,Omnichroma 显示出最高的 ΔE₀₀ 值(在胶片组 O 与 F 相比,P< 0.001;O 与 H 相比,P< 0.001;O 与 E 相比,P< 0.001)。就单体转换程度而言,复合组之间存在明显差异(P< 0.05)。Omnichroma的变色程度明显最高:临床意义:不同的抛光程序对当前的复合材料表面显示出有效的性能。Omnichroma 树脂复合材料的变色程度高于具有类似性质的复合材料。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
American journal of dentistry
American journal of dentistry 医学-牙科与口腔外科
CiteScore
2.40
自引率
7.10%
发文量
57
审稿时长
1 months
期刊介绍: The American Journal of Dentistry, published by Mosher & Linder, Inc., provides peer-reviewed scientific articles with clinical significance for the general dental practitioner.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信