Three data-selection approaches for beam position monitor offline calibration

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
Geunwoo Kim, Eun-San Kim, Jang Won Kwon, Siwon Jang
{"title":"Three data-selection approaches for beam position monitor offline calibration","authors":"Geunwoo Kim, Eun-San Kim, Jang Won Kwon, Siwon Jang","doi":"10.1088/1748-0221/19/06/T06006","DOIUrl":null,"url":null,"abstract":"In this study, we describe the fabrication of an electrostatic beam position monitor (BPM) for beam diagnostic systems. Calibration of the BPM pickup requires both sensitivity and curve fitting owing to manufacturing tolerances following fabrication. To calibrate the BPM, we developed a BPM calibration system that comprises a wire-based test bench and readout electronics. We considered three difference-over-sum (DOS) data selection methods: DOSdiag, DOSaxis, and DOSall, to understand their impact on calibration accuracy. Each method selected specific DOS data, and we compared their characteristic curves. Consequently, we analyzed the calibration results by performing linear, 3rd-order, 5th-order, and two-dimensional (2D) 3rd-order polynomial fitting. Each of the three DOS data selection methods was examined to illustrate their advantages and limitations in terms of calibration accuracy and required amount of data. The results obtained demonstrated that choosing the appropriate DOS data-selection approach could be employed for the BPM offline calibrations, achieving minimized calibration errors and optimized response characteristics with polynomial curve fitting.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1748-0221/19/06/T06006","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, we describe the fabrication of an electrostatic beam position monitor (BPM) for beam diagnostic systems. Calibration of the BPM pickup requires both sensitivity and curve fitting owing to manufacturing tolerances following fabrication. To calibrate the BPM, we developed a BPM calibration system that comprises a wire-based test bench and readout electronics. We considered three difference-over-sum (DOS) data selection methods: DOSdiag, DOSaxis, and DOSall, to understand their impact on calibration accuracy. Each method selected specific DOS data, and we compared their characteristic curves. Consequently, we analyzed the calibration results by performing linear, 3rd-order, 5th-order, and two-dimensional (2D) 3rd-order polynomial fitting. Each of the three DOS data selection methods was examined to illustrate their advantages and limitations in terms of calibration accuracy and required amount of data. The results obtained demonstrated that choosing the appropriate DOS data-selection approach could be employed for the BPM offline calibrations, achieving minimized calibration errors and optimized response characteristics with polynomial curve fitting.
用于光束位置监测器离线校准的三种数据选择方法
在本研究中,我们介绍了用于光束诊断系统的静电光束位置监测器(BPM)的制造过程。校准 BPM 拾波器需要灵敏度和曲线拟合,这是因为制造过程中存在制造公差。为了校准 BPM,我们开发了一套 BPM 校准系统,该系统由线性测试台和读出电子设备组成。我们考虑了三种求和差(DOS)数据选择方法:DOSdiag、DOSaxis 和 DOSall,以了解它们对校准精度的影响。每种方法都选择了特定的 DOS 数据,我们比较了它们的特性曲线。因此,我们通过进行线性、三阶、五阶和二维(2D)三阶多项式拟合来分析校准结果。我们对三种 DOS 数据选择方法进行了研究,以说明它们在校准精度和所需数据量方面的优势和局限性。研究结果表明,选择适当的 DOS 数据选择方法可用于 BPM 离线校准,通过多项式曲线拟合实现校准误差最小化和响应特性最优化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信