Performance Evaluation of Semi-quantitative Urine Albumin Creatinine Ratio Using Meditape UC-11A Strip Test

Elizabeth Sidhartha, Thoeng Ronald
{"title":"Performance Evaluation of Semi-quantitative Urine Albumin Creatinine Ratio Using Meditape UC-11A Strip Test","authors":"Elizabeth Sidhartha, Thoeng Ronald","doi":"10.24293/ijcpml.v30i3.2231","DOIUrl":null,"url":null,"abstract":"The Urine Albumin/Creatinine Ratio (uACR) is one of the earliest markers of glomerular disorders. A comparative study of semi-quantitative urine uACR and quantitative uACR tests was carried out using Meditape UC-11A test strips on the Sysmex UC-3500 (automated urinalysis instrument) and Roche Cobas 501, respectively. A total of 213 retrospective data of urine chemistry tests were collected. Semi-quantitative urine albumin, creatinine, and uACR data were obtained using Meditape UC-11A strips on Sysmex UC-3500, whereas quantitative data were obtained using Roche Cobas c501. A weighted Cohen's Kappa agreement, sensitivity, specificity, PPV, NPV, and accuracy were analyzed using data from both instruments. The Kappa values for urine albumin, creatinine,  and uACR between the semi-quantitative and quantitative methods were 0.83 (CI 0.771– 0.880), 0.535 (CI 0.417–0.652), and 0.691 (CI 0.606–0.775), respectively. The sensitivity, specificity, PPV, NPV, and accuracy of semi-quantitative methods were 90%, 73.3%, 75%, 89.2%, and 81.2%, respectively. The semi-quantitative uACR test on the UC-3500 showed excellent performance and could be used as a screening test for early detection of impaired kidney function.","PeriodicalId":354500,"journal":{"name":"Indonesian Journal of Clinical Pathology and Medical Laboratory","volume":"27 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indonesian Journal of Clinical Pathology and Medical Laboratory","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24293/ijcpml.v30i3.2231","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The Urine Albumin/Creatinine Ratio (uACR) is one of the earliest markers of glomerular disorders. A comparative study of semi-quantitative urine uACR and quantitative uACR tests was carried out using Meditape UC-11A test strips on the Sysmex UC-3500 (automated urinalysis instrument) and Roche Cobas 501, respectively. A total of 213 retrospective data of urine chemistry tests were collected. Semi-quantitative urine albumin, creatinine, and uACR data were obtained using Meditape UC-11A strips on Sysmex UC-3500, whereas quantitative data were obtained using Roche Cobas c501. A weighted Cohen's Kappa agreement, sensitivity, specificity, PPV, NPV, and accuracy were analyzed using data from both instruments. The Kappa values for urine albumin, creatinine,  and uACR between the semi-quantitative and quantitative methods were 0.83 (CI 0.771– 0.880), 0.535 (CI 0.417–0.652), and 0.691 (CI 0.606–0.775), respectively. The sensitivity, specificity, PPV, NPV, and accuracy of semi-quantitative methods were 90%, 73.3%, 75%, 89.2%, and 81.2%, respectively. The semi-quantitative uACR test on the UC-3500 showed excellent performance and could be used as a screening test for early detection of impaired kidney function.
使用 Meditape UC-11A 试纸对半定量尿液白蛋白肌酐比值进行性能评估
尿白蛋白/肌酐比值(uACR)是肾小球疾病的最早标志之一。在 Sysmex UC-3500(自动尿液分析仪)和罗氏 Cobas 501 上分别使用 Meditape UC-11A 试纸对半定量尿液白蛋白/肌酐比值和定量尿液白蛋白/肌酐比值进行了比较研究。共收集了 213 项尿液化学检验回顾性数据。在 Sysmex UC-3500 上使用 Meditape UC-11A 试纸获得了半定量尿白蛋白、肌酐和 uACR 数据,而使用罗氏 Cobas c501 则获得了定量数据。使用这两种仪器的数据对加权科恩卡帕一致性、灵敏度、特异性、PPV、NPV 和准确性进行了分析。尿白蛋白、肌酐和 uACR 的半定量和定量方法的 Kappa 值分别为 0.83(CI 0.771-0.880)、0.535(CI 0.417-0.652)和 0.691(CI 0.606-0.775)。半定量方法的敏感性、特异性、PPV、NPV 和准确性分别为 90%、73.3%、75%、89.2% 和 81.2%。UC-3500上的半定量uACR测试表现优异,可用作早期发现肾功能受损的筛查测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信