Nour Mohamed Kandil, Aya Mohamed Bassam Hashem, Marwan Mohamed El Toukhy, Nouran Mohamed Abdalla Atris Yousef, Ahmed Saeed Hussein Al-Feeshawy, Maged Abdel Rahman Havwana
{"title":"Ultrasound imaging and shear wave elastography for the differential diagnosis of heel pain: a comparative cross-sectional study.","authors":"Nour Mohamed Kandil, Aya Mohamed Bassam Hashem, Marwan Mohamed El Toukhy, Nouran Mohamed Abdalla Atris Yousef, Ahmed Saeed Hussein Al-Feeshawy, Maged Abdel Rahman Havwana","doi":"10.1007/s40477-024-00906-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>In correlation with magnetic resonance imaging (MRI), this study attempts to assess the effectiveness of the diagnostic of ultrasonography (US) features and shear wave elastography (SWE) in determining the different causes of heel pain.</p><p><strong>Materials and methods: </strong>55 heels with a mean age of 38.33 ± 10.8 were included in the study (10 control cases and 41 cases, 4 of which had bilateral heel pain). There were 23 female cases (56.1%) and 18 male cases (43.95%). Examinations using shear wave elastography (SWE) and ultrasound (US) were done in different positions. MRI and the obtained data were correlated.</p><p><strong>Results: </strong>When used to diagnose different heel pain causes, ultrasound demonstrated great sensitivity and specificity. SWE demonstrated a good correlation with MRI findings and enhanced the ultrasound's diagnostic precision in identifying plantar fasciitis early on (increased accuracy from 88.9 to 93.33% with 100% sensitivity and 83.3% specificity) and Achilles tendinopathy (increased accuracy from 88.9 to 97.8 with 94.7% sensitivity and 100% specificity).</p><p><strong>Conclusion: </strong>In summary, we concluded that heel pain can be efficiently examined by both ultrasound (US) and shear wave elastography (SWE) with the former being used as the primary effective tool and the latter being done to increase diagnostic accuracy. We also concluded that SWE improved the ultrasound's diagnostic precision in identifying patients with early plantar fasciitis and Achilles tendinopathy and showed a robust relationship with clinical outcomes, enhancing patient evaluation and follow-up.</p>","PeriodicalId":51528,"journal":{"name":"Journal of Ultrasound","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11333687/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s40477-024-00906-8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/16 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: In correlation with magnetic resonance imaging (MRI), this study attempts to assess the effectiveness of the diagnostic of ultrasonography (US) features and shear wave elastography (SWE) in determining the different causes of heel pain.
Materials and methods: 55 heels with a mean age of 38.33 ± 10.8 were included in the study (10 control cases and 41 cases, 4 of which had bilateral heel pain). There were 23 female cases (56.1%) and 18 male cases (43.95%). Examinations using shear wave elastography (SWE) and ultrasound (US) were done in different positions. MRI and the obtained data were correlated.
Results: When used to diagnose different heel pain causes, ultrasound demonstrated great sensitivity and specificity. SWE demonstrated a good correlation with MRI findings and enhanced the ultrasound's diagnostic precision in identifying plantar fasciitis early on (increased accuracy from 88.9 to 93.33% with 100% sensitivity and 83.3% specificity) and Achilles tendinopathy (increased accuracy from 88.9 to 97.8 with 94.7% sensitivity and 100% specificity).
Conclusion: In summary, we concluded that heel pain can be efficiently examined by both ultrasound (US) and shear wave elastography (SWE) with the former being used as the primary effective tool and the latter being done to increase diagnostic accuracy. We also concluded that SWE improved the ultrasound's diagnostic precision in identifying patients with early plantar fasciitis and Achilles tendinopathy and showed a robust relationship with clinical outcomes, enhancing patient evaluation and follow-up.
期刊介绍:
The Journal of Ultrasound is the official journal of the Italian Society for Ultrasound in Medicine and Biology (SIUMB). The journal publishes original contributions (research and review articles, case reports, technical reports and letters to the editor) on significant advances in clinical diagnostic, interventional and therapeutic applications, clinical techniques, the physics, engineering and technology of ultrasound in medicine and biology, and in cross-sectional diagnostic imaging. The official language of Journal of Ultrasound is English.