A sandwich-type photoelectrochemical biosensor based on Ru(bpy)32+ sensitized In2S3 for aflatoxin B1 detection†

IF 3.6 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Analyst Pub Date : 2024-06-10 DOI:10.1039/D4AN00612G
Si-Zhe Chen, Jing-Shuai Chen, Xing-Pei Liu, Chang-Jie Mao and Bao-Kang Jin
{"title":"A sandwich-type photoelectrochemical biosensor based on Ru(bpy)32+ sensitized In2S3 for aflatoxin B1 detection†","authors":"Si-Zhe Chen, Jing-Shuai Chen, Xing-Pei Liu, Chang-Jie Mao and Bao-Kang Jin","doi":"10.1039/D4AN00612G","DOIUrl":null,"url":null,"abstract":"<p >Aflatoxin B<small><sub>1</sub></small> (AFB<small><sub>1</sub></small>), classified as a class I carcinogen, is a widespread mycotoxin that poses a serious threat to public health and economic development, and the food safety problems caused by AFB<small><sub>1</sub></small> have aroused worldwide concern. The development of accurate and sensitive methods for the detection of AFB<small><sub>1</sub></small> is significant for food safety monitoring. In this work, a sandwich-type photoelectrochemical (PEC) biosensor for AFB<small><sub>1</sub></small> detection was constructed on the basis of an aptamer–antibody structure. A good photocurrent response was obtained due to the sensitization of In<small><sub>2</sub></small>S<small><sub>3</sub></small> by Ru(bpy)<small><sub>3</sub></small><small><sup>2+</sup></small>. In addition, this sandwich-type sensor constructed by modification with the antibody, target detector, and aptamer layer by layer attenuated the migration hindering effect of photogenerated carriers caused by the double antibody structure. The aptamer and antibody synergistically recognized and captured the target analyte, resulting in more reliable PEC response signals. CdSe@CdS QDs-Apt were modified as a signal-off probe onto the sensor platform to quantitatively detect AFB<small><sub>1</sub></small> with a “signal-off” response, which enhanced the sensitivity of the sensor. The PEC biosensor showed a linear response range from 10<small><sup>−12</sup></small> to 10<small><sup>−6</sup></small> g mL<small><sup>−1</sup></small> with a detection limit of 0.023 pg mL<small><sup>−1</sup></small>, providing a feasible approach for the quantitative detection of AFB<small><sub>1</sub></small> in food samples.</p>","PeriodicalId":63,"journal":{"name":"Analyst","volume":null,"pages":null},"PeriodicalIF":3.6000,"publicationDate":"2024-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analyst","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/an/d4an00612g","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Aflatoxin B1 (AFB1), classified as a class I carcinogen, is a widespread mycotoxin that poses a serious threat to public health and economic development, and the food safety problems caused by AFB1 have aroused worldwide concern. The development of accurate and sensitive methods for the detection of AFB1 is significant for food safety monitoring. In this work, a sandwich-type photoelectrochemical (PEC) biosensor for AFB1 detection was constructed on the basis of an aptamer–antibody structure. A good photocurrent response was obtained due to the sensitization of In2S3 by Ru(bpy)32+. In addition, this sandwich-type sensor constructed by modification with the antibody, target detector, and aptamer layer by layer attenuated the migration hindering effect of photogenerated carriers caused by the double antibody structure. The aptamer and antibody synergistically recognized and captured the target analyte, resulting in more reliable PEC response signals. CdSe@CdS QDs-Apt were modified as a signal-off probe onto the sensor platform to quantitatively detect AFB1 with a “signal-off” response, which enhanced the sensitivity of the sensor. The PEC biosensor showed a linear response range from 10−12 to 10−6 g mL−1 with a detection limit of 0.023 pg mL−1, providing a feasible approach for the quantitative detection of AFB1 in food samples.

Abstract Image

Abstract Image

基于 Ru(bpy)32+ 敏化 In2S3 的夹层式光电化学生物传感器,用于检测黄曲霉毒素 B1。
黄曲霉毒素 B1(AFB1)被列为一级致癌物,是一种广泛存在的霉菌毒素,对公众健康和经济发展构成严重威胁。开发准确、灵敏的 AFB1 检测方法对食品安全监测具有重要意义。本研究基于适配体-抗体结构,构建了一种用于检测 AFB1 的夹心型光电化学(PEC)生物传感器。由于 Ru(bpy)32+ 对 In2S3 的敏化作用,该传感器获得了良好的光电流响应。此外,这种由抗体、目标检测器和适配体逐层修饰而成的夹层式传感器还减弱了双抗体结构对光生载流子迁移的阻碍作用。适配体和抗体协同识别并捕获目标分析物,从而产生更可靠的 PEC 响应信号。将 CdSe@CdS QDs-Apt 作为信号截止探针修饰到传感器平台上,以 "信号截止 "响应定量检测 AFB1,提高了传感器的灵敏度。PEC 生物传感器的线性响应范围为 10-12 至 10-6 g mL-1,检测限为 0.023 pg mL-1,为食品样品中 AFB1 的定量检测提供了一种可行的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Analyst
Analyst 化学-分析化学
CiteScore
7.80
自引率
4.80%
发文量
636
审稿时长
1.9 months
期刊介绍: The home of premier fundamental discoveries, inventions and applications in the analytical and bioanalytical sciences
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信