The Long-term Visual Quality and Rotational Stability After ICL/TICL V4c Implantation in Individuals With High Myopia Older Than 40 Years.

IF 2.9 3区 医学 Q1 OPHTHALMOLOGY
Yuhao Ye, Yijia Xu, Zhe Zhang, Lingling Niu, Wanru Shi, Xiaoying Wang, Xingtao Zhou, Jing Zhao
{"title":"The Long-term Visual Quality and Rotational Stability After ICL/TICL V4c Implantation in Individuals With High Myopia Older Than 40 Years.","authors":"Yuhao Ye, Yijia Xu, Zhe Zhang, Lingling Niu, Wanru Shi, Xiaoying Wang, Xingtao Zhou, Jing Zhao","doi":"10.3928/1081597X-20240422-04","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the long-term visual quality and rotational stability after the implantation of Implantable Collamer Lens (ICL) and toric ICL (TICL) (STAAR Surgical) in patients with myopia older than 40 years.</p><p><strong>Methods: </strong>This study included 82 eyes of 41 patients older than 40 years with myopia who underwent ICL/TICL V4c implantation. The refraction sphere, refraction cylinder, spherical equivalent (SE), uncorrected and corrected distance visual acuity, and anterior segmental parameters were measured preoperatively and at the 1-month, 3-month, and last follow-up visits at 33 to 58 months postoperatively (mean follow-up: 42.56 ± 7.17 months). Wavefront aberrations and TICL rotation were measured using OPD-Scan III (Nidek Co Ltd) at the last follow-up visit.</p><p><strong>Results: </strong>At the last follow-up visit, the overall safety and efficacy index were 1.22 ± 0.26 and 0.88 ± 0.34, respectively, without significant differences between the ICL and TICL groups. Postoperative refraction cylinder was -0.95 ± 0.64 and -0.71 ± 0.54 diopters in the ICL and TICL groups, respectively. The average vault was 467.44 ± 231.98 µm. The average TICL rotation was 5.45 ± 6.61 degrees, positively correlated with the preoperative anterior chamber volume (<i>R</i><sup>2</sup> = 0.1118, <i>P</i> = .026) and clockwise TICL alignment degree (<i>R</i><sup>2</sup> = 0.3110, <i>P</i> = .007) and negatively correlated with the 1-month vault (<i>R</i><sup>2</sup> = 0.1218, <i>P</i> = .008). There were no significant differences in the total, corneal, or internal aberrations and modulation transfer function AreaRatio between the ICL and TICL groups.</p><p><strong>Conclusions: </strong>Both ICL and TICL presented satisfactory long-term safety, efficacy, and visual quality in patients older than 40 years. Postoperative TICL spontaneous rotation was within the manageable range in the long term. <b>[<i>J Refract Surg</i>. 2024;40(6):e381-e391.]</b>.</p>","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"40 6","pages":"e381-e391"},"PeriodicalIF":2.9000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597X-20240422-04","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To investigate the long-term visual quality and rotational stability after the implantation of Implantable Collamer Lens (ICL) and toric ICL (TICL) (STAAR Surgical) in patients with myopia older than 40 years.

Methods: This study included 82 eyes of 41 patients older than 40 years with myopia who underwent ICL/TICL V4c implantation. The refraction sphere, refraction cylinder, spherical equivalent (SE), uncorrected and corrected distance visual acuity, and anterior segmental parameters were measured preoperatively and at the 1-month, 3-month, and last follow-up visits at 33 to 58 months postoperatively (mean follow-up: 42.56 ± 7.17 months). Wavefront aberrations and TICL rotation were measured using OPD-Scan III (Nidek Co Ltd) at the last follow-up visit.

Results: At the last follow-up visit, the overall safety and efficacy index were 1.22 ± 0.26 and 0.88 ± 0.34, respectively, without significant differences between the ICL and TICL groups. Postoperative refraction cylinder was -0.95 ± 0.64 and -0.71 ± 0.54 diopters in the ICL and TICL groups, respectively. The average vault was 467.44 ± 231.98 µm. The average TICL rotation was 5.45 ± 6.61 degrees, positively correlated with the preoperative anterior chamber volume (R2 = 0.1118, P = .026) and clockwise TICL alignment degree (R2 = 0.3110, P = .007) and negatively correlated with the 1-month vault (R2 = 0.1218, P = .008). There were no significant differences in the total, corneal, or internal aberrations and modulation transfer function AreaRatio between the ICL and TICL groups.

Conclusions: Both ICL and TICL presented satisfactory long-term safety, efficacy, and visual quality in patients older than 40 years. Postoperative TICL spontaneous rotation was within the manageable range in the long term. [J Refract Surg. 2024;40(6):e381-e391.].

40 岁以上高度近视患者植入 ICL/TICL V4c 后的长期视觉质量和旋转稳定性。
目的:调查 40 岁以上近视患者植入可植入角膜接触镜(ICL)和散光 ICL(TICL)(STAAR Surgical)后的长期视觉质量和旋转稳定性:这项研究包括 41 名 40 岁以上近视患者的 82 只眼睛,他们都接受了 ICL/TICL V4c 植入术。术前、术后 1 个月、3 个月和术后 33 至 58 个月的最后一次随访(平均随访时间:42.56 ± 7.17 个月)时测量了屈光球、屈光圆柱、球面等值(SE)、未矫正和矫正的远距离视力以及眼前节参数。在最后一次随访时,使用 OPD-Scan III(Nidek Co Ltd)测量波前像差和 TICL 旋转:最后一次随访时,ICL组和TICL组的总体安全性和有效性指数分别为(1.22 ± 0.26)和(0.88 ± 0.34),无显著差异。ICL 组和 TICL 组术后屈光圆柱度分别为 -0.95 ± 0.64 和 -0.71 ± 0.54 斜度。平均穹隆为 467.44 ± 231.98 µm。TICL 平均旋转度为 5.45 ± 6.61 度,与术前前房体积(R2 = 0.1118,P = .026)和 TICL 顺时针排列度(R2 = 0.3110,P = .007)呈正相关,与 1 个月后的穹窿呈负相关(R2 = 0.1218,P = .008)。ICL 组和 TICL 组的总像差、角膜像差、内像差和调制传递函数面积比无明显差异:结论:对于 40 岁以上的患者,ICL 和 TICL 的长期安全性、疗效和视觉质量都令人满意。TICL术后自发旋转长期处于可控范围内。[J Refract Surg. 2024;40(6):e381-e391]。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.10
自引率
12.50%
发文量
160
审稿时长
4-8 weeks
期刊介绍: The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as: • Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics” • Supplemental videos and materials available for many articles • Access to current articles, as well as several years of archived content • Articles posted online just 2 months after acceptance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信