The effect of combining primers and cements from different cement systems on the bond strength between zirconia and dentin.

IF 2.5 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Minh Le, Evaggelia Papia, Christel Larsson
{"title":"The effect of combining primers and cements from different cement systems on the bond strength between zirconia and dentin.","authors":"Minh Le, Evaggelia Papia, Christel Larsson","doi":"10.1038/s41405-024-00230-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The aim of this study was to evaluate the influence of combining primers and cements from two different resin cement systems on the microtensile bond strength (μTBS) between zirconia and human dentin.</p><p><strong>Materials and methods: </strong>A total of 120 specimens of zirconia cemented to dentin were allocated into eight groups based on cement type (RelyX Ultimate or Panavia V5) and primers (Tooth Primer, Clearfil Ceramic Primer and Scotchbond Universal Adhesive) combinations, applied to dentin or ceramic surfaces. Following artificial aging with 5000 thermocycles, μTBS tests were conducted. Statistical analysis was performed using One-way ANOVA and Tukey's post hoc tests (p ≤ 0.05), and failure modes were assessed.</p><p><strong>Results: </strong>The Panavia V5 cement system demonstrated the highest bond strength (19.4 ± 4.4 MPa), significantly higher than the other groups except when RelyX cement was used with Panavia primers (16.9 ± 3.7 MPa). Cohesive fractures within the cement layer were the predominant failure mode.</p><p><strong>Conclusions: </strong>The combination of primers from different adhesive cement system brands may significantly affect the bonding effectiveness. Therefore, using products from a single product line of the same adhesive cement system, and following the manufacturer's recommendations for indications and use, is crucial for a more predictable clinical outcome.</p>","PeriodicalId":36997,"journal":{"name":"BDJ Open","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2024-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11153574/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BDJ Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1038/s41405-024-00230-7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The aim of this study was to evaluate the influence of combining primers and cements from two different resin cement systems on the microtensile bond strength (μTBS) between zirconia and human dentin.

Materials and methods: A total of 120 specimens of zirconia cemented to dentin were allocated into eight groups based on cement type (RelyX Ultimate or Panavia V5) and primers (Tooth Primer, Clearfil Ceramic Primer and Scotchbond Universal Adhesive) combinations, applied to dentin or ceramic surfaces. Following artificial aging with 5000 thermocycles, μTBS tests were conducted. Statistical analysis was performed using One-way ANOVA and Tukey's post hoc tests (p ≤ 0.05), and failure modes were assessed.

Results: The Panavia V5 cement system demonstrated the highest bond strength (19.4 ± 4.4 MPa), significantly higher than the other groups except when RelyX cement was used with Panavia primers (16.9 ± 3.7 MPa). Cohesive fractures within the cement layer were the predominant failure mode.

Conclusions: The combination of primers from different adhesive cement system brands may significantly affect the bonding effectiveness. Therefore, using products from a single product line of the same adhesive cement system, and following the manufacturer's recommendations for indications and use, is crucial for a more predictable clinical outcome.

Abstract Image

不同水门汀系统的底漆和水门汀的组合对氧化锆和牙本质之间粘接强度的影响。
研究目的本研究的目的是评估两种不同树脂粘接剂系统的底涂剂和粘接剂的组合对氧化锆和人类牙本质之间的微拉伸粘接强度(μTBS)的影响:根据应用于牙本质或陶瓷表面的粘结剂类型(RelyX Ultimate 或 Panavia V5)和底涂(Tooth Primer、Clearfil Ceramic Primer 和 Scotchbond Universal Adhesive)组合,将 120 个与牙本质粘结的氧化锆试样分为 8 组。经过 5000 个热循环的人工老化后,进行 μTBS 测试。使用单因素方差分析和 Tukey 后检验(p ≤ 0.05)进行统计分析,并对失效模式进行评估:结果:Panavia V5水门汀系统的粘结强度最高(19.4 ± 4.4 MPa),明显高于其他组别,但使用RelyX水门汀和Panavia底漆时除外(16.9 ± 3.7 MPa)。水泥层内的内聚性断裂是主要的破坏模式:结论:不同品牌粘接剂系统的底涂组合可能会严重影响粘接效果。因此,使用同一粘接骨水泥系统的单一产品系列的产品,并遵循制造商关于适应症和使用的建议,对于获得更可预测的临床结果至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BDJ Open
BDJ Open Dentistry-Dentistry (all)
CiteScore
3.70
自引率
3.30%
发文量
34
审稿时长
30 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信