Complications Following Short Femoral Nail Fixation for Intertrochanteric Hip Fractures: A Retrospective Study.

Q3 Dentistry
Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, C Nikakis, Stavros Angelis, Spyridon J Maris, C Grekas, Efthymios J Karadimas, Alexandros P Apostolopoulos
{"title":"Complications Following Short Femoral Nail Fixation for Intertrochanteric Hip Fractures: A Retrospective Study.","authors":"Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, C Nikakis, Stavros Angelis, Spyridon J Maris, C Grekas, Efthymios J Karadimas, Alexandros P Apostolopoulos","doi":"10.1615/JLongTermEffMedImplants.2023048205","DOIUrl":null,"url":null,"abstract":"<p><p>The incidence of proximal femur fractures is increasing due to aging of the population. Intramedullary nails are the mainstay of treatment for intertrochanteric hip fractures mainly due to their better biomechanical properties compared to dynamic hip screw devices, shorter operative time, and less blood loss during surgery. However intramedullary nail fixation is not devoid of complications. The purpose of this study is to look at complications related to intramedullary nailing for intertrochanteric hip fractures in a major trauma center. A retrospective study was conducted including all patients having suffered an intertrochanteric femur fracture and treated with intramedullary nails from October 1, 2020, to October 1, 2022, in the Orthopaedic Surgery Clinic. The intramedullary hip systems used were the Stryker Gamma3 Nail and the VITUS PF Nail. All complications following the postoperative period were recorded in detail. Overall, 240 patients with a mean age of 82.3 years treated with hip intramedullary devices were identified. Superior cutout of the lag screw in two patients (females 90 and 87 years old) was identified 8 and 10 weeks following initial surgery. Avascular necrosis (AVN) of the femoral head was identified in one patient (male 81 years old) which occurred 12 weeks postoperatively. All three cases were revised by replacing the nail with cemented hemiarthroplasty. Periprosthetic fractures occurred in an 88-year-old male and a 73-year-old female following an injury distal to the stem and were managed by replacing the nail with a long stem device (Long Gamma3). One case of metalwork fracture was also recorded. There are many advantages in managing intertrochanteric hip fractures with intramedullary hip devices such as shorter theater time, less blood loss, and improved biomechanical properties. However, complications such as cutout of the lag screw, AVN, and periprosthetic fracture are serious and require complex revision surgery.</p>","PeriodicalId":16125,"journal":{"name":"Journal of long-term effects of medical implants","volume":"34 4","pages":"23-32"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of long-term effects of medical implants","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1615/JLongTermEffMedImplants.2023048205","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

The incidence of proximal femur fractures is increasing due to aging of the population. Intramedullary nails are the mainstay of treatment for intertrochanteric hip fractures mainly due to their better biomechanical properties compared to dynamic hip screw devices, shorter operative time, and less blood loss during surgery. However intramedullary nail fixation is not devoid of complications. The purpose of this study is to look at complications related to intramedullary nailing for intertrochanteric hip fractures in a major trauma center. A retrospective study was conducted including all patients having suffered an intertrochanteric femur fracture and treated with intramedullary nails from October 1, 2020, to October 1, 2022, in the Orthopaedic Surgery Clinic. The intramedullary hip systems used were the Stryker Gamma3 Nail and the VITUS PF Nail. All complications following the postoperative period were recorded in detail. Overall, 240 patients with a mean age of 82.3 years treated with hip intramedullary devices were identified. Superior cutout of the lag screw in two patients (females 90 and 87 years old) was identified 8 and 10 weeks following initial surgery. Avascular necrosis (AVN) of the femoral head was identified in one patient (male 81 years old) which occurred 12 weeks postoperatively. All three cases were revised by replacing the nail with cemented hemiarthroplasty. Periprosthetic fractures occurred in an 88-year-old male and a 73-year-old female following an injury distal to the stem and were managed by replacing the nail with a long stem device (Long Gamma3). One case of metalwork fracture was also recorded. There are many advantages in managing intertrochanteric hip fractures with intramedullary hip devices such as shorter theater time, less blood loss, and improved biomechanical properties. However, complications such as cutout of the lag screw, AVN, and periprosthetic fracture are serious and require complex revision surgery.

股骨短钉固定治疗转子间髋部骨折后的并发症:回顾性研究
由于人口老龄化,股骨近端骨折的发病率不断上升。髓内钉是治疗髋关节转子间骨折的主要方法,这主要是因为与动态髋关节螺钉装置相比,髓内钉具有更好的生物力学特性,手术时间更短,术中失血更少。然而,髓内钉固定并非没有并发症。本研究的目的是在一家大型创伤中心调查髓内钉治疗髋关节转子间骨折的相关并发症。这项回顾性研究的对象包括 2020 年 10 月 1 日至 2022 年 10 月 1 日期间在骨科手术诊所接受髓内钉治疗的所有股骨转子间骨折患者。使用的髓内髋关节系统是史赛克 Gamma3 钉和 VITUS PF 钉。所有术后并发症均有详细记录。共有 240 名患者接受了髋关节髓内装置治疗,平均年龄为 82.3 岁。两名患者(女性,分别为 90 岁和 87 岁)在初次手术后 8 周和 10 周发现滞后螺钉上端切口。一名患者(男性,81 岁)在术后 12 周发现股骨头血管坏死(AVN)。所有三个病例均通过骨水泥半关节置换术更换了钉子。一名88岁的男性和一名73岁的女性在骨干远端受伤后发生了假体周围骨折,通过用长骨干装置(Long Gamma3)替换钢钉进行了处理。此外还记录了一例金属制品骨折。使用髓内髋关节装置治疗转子间髋部骨折有很多优点,如缩短手术时间、减少失血和改善生物力学特性。然而,滞后螺钉切出、AVN 和假体周围骨折等并发症非常严重,需要进行复杂的翻修手术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.20
自引率
0.00%
发文量
46
期刊介绍: MEDICAL IMPLANTS are being used in every organ of the human body. Ideally, medical implants must have biomechanical properties comparable to those of autogenous tissues without any adverse effects. In each anatomic site, studies of the long-term effects of medical implants must be undertaken to determine accurately the safety and performance of the implants. Today, implant surgery has become an interdisciplinary undertaking involving a number of skilled and gifted specialists. For example, successful cochlear implants will involve audiologists, audiological physicians, speech and language therapists, otolaryngologists, nurses, neuro-otologists, teachers of the deaf, hearing therapists, cochlear implant manufacturers, and others involved with hearing-impaired and deaf individuals.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信