{"title":"Review Article - Diabetes Technology in the Hospital: An Update.","authors":"Margaretha M Visser, Roman Vangoitsenhoven, Pieter Gillard, Chantal Mathieu","doi":"10.1007/s11892-024-01545-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose of review: </strong>There have been many developments in diabetes technology in recent years, with continuous glucose monitoring (CGM), insulin pump therapy (CSII) and automated insulin delivery (AID) becoming progressively accepted in outpatient diabetes care. However, the use of such advanced diabetes technology in the inpatient setting is still limited for several reasons, including logistical challenges and staff training needs. On the other hand, hospital settings with altered diet and stress-induced hyperglycemia often pose challenges to tight glycemic control using conventional treatment tools. Integrating smarter glucose monitoring and insulin delivery devices into the increasingly technical hospital environment could reduce diabetes-related morbidity and mortality. This narrative review describes the most recent literature on the use of diabetes technology in the hospital and suggests avenues for further research.</p><p><strong>Recent findings: </strong>Advanced diabetes technology has the potential to improve glycemic control in hospitalized people with and without diabetes, and could add particular value in certain conditions, such as nutrition therapy or perioperative management. Taken together, CGM allows for more accurate and patient-friendly follow-up and ad hoc titration of therapy. AID may also provide benefits, including improved glycemic control and reduced nursing workload. Before advanced diabetes technology can be used on a large scale in the hospital, further research is needed on efficacy, accuracy and safety, while implementation factors such as cost and staff training must also be overcome.</p>","PeriodicalId":10898,"journal":{"name":"Current Diabetes Reports","volume":" ","pages":"173-182"},"PeriodicalIF":5.2000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Diabetes Reports","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11892-024-01545-3","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/6 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose of review: There have been many developments in diabetes technology in recent years, with continuous glucose monitoring (CGM), insulin pump therapy (CSII) and automated insulin delivery (AID) becoming progressively accepted in outpatient diabetes care. However, the use of such advanced diabetes technology in the inpatient setting is still limited for several reasons, including logistical challenges and staff training needs. On the other hand, hospital settings with altered diet and stress-induced hyperglycemia often pose challenges to tight glycemic control using conventional treatment tools. Integrating smarter glucose monitoring and insulin delivery devices into the increasingly technical hospital environment could reduce diabetes-related morbidity and mortality. This narrative review describes the most recent literature on the use of diabetes technology in the hospital and suggests avenues for further research.

Recent findings: Advanced diabetes technology has the potential to improve glycemic control in hospitalized people with and without diabetes, and could add particular value in certain conditions, such as nutrition therapy or perioperative management. Taken together, CGM allows for more accurate and patient-friendly follow-up and ad hoc titration of therapy. AID may also provide benefits, including improved glycemic control and reduced nursing workload. Before advanced diabetes technology can be used on a large scale in the hospital, further research is needed on efficacy, accuracy and safety, while implementation factors such as cost and staff training must also be overcome.

评论文章--医院中的糖尿病技术:最新进展。
回顾的目的:近年来,糖尿病技术有了许多发展,连续血糖监测(CGM)、胰岛素泵疗法(CSII)和自动胰岛素输送(AID)逐渐被门诊糖尿病护理所接受。然而,在住院环境中使用这些先进的糖尿病技术仍然受到限制,原因有几个,包括后勤挑战和员工培训需求。另一方面,医院环境中的饮食改变和压力导致的高血糖往往对使用传统治疗工具严格控制血糖构成挑战。将更智能的血糖监测和胰岛素给药设备整合到技术含量越来越高的医院环境中,可以降低与糖尿病相关的发病率和死亡率。本综述介绍了有关在医院使用糖尿病技术的最新文献,并提出了进一步研究的途径:先进的糖尿病技术有可能改善住院糖尿病患者和非糖尿病患者的血糖控制,在某些情况下,如营养治疗或围术期管理,还能增加特别的价值。总之,血糖监测仪可以进行更准确、更方便患者的随访,并对治疗进行特别调整。AID 也能带来好处,包括改善血糖控制和减轻护理工作量。在医院大规模使用先进的糖尿病技术之前,还需要进一步研究其疗效、准确性和安全性,同时还必须克服成本和人员培训等实施因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
9.80
自引率
0.00%
发文量
52
审稿时长
6-12 weeks
期刊介绍: The goal of this journal is to publish cutting-edge reviews on subjects pertinent to all aspects of diabetes epidemiology, pathophysiology, and management. We aim to provide incisive, insightful, and balanced contributions from leading experts in each relevant domain that will be of immediate interest to a wide readership of clinicians, basic scientists, and translational investigators. We accomplish this aim by appointing major authorities to serve as Section Editors in key subject areas across the discipline. Section Editors select topics to be reviewed by leading experts who emphasize recent developments and highlight important papers published over the past year on their topics, in a crisp and readable format. We also provide commentaries from well-known figures in the field, and an Editorial Board of internationally diverse members suggests topics of special interest to their country/region and ensures that topics are current and include emerging research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信