Improving a regional project on diagnostic reference levels for interventional procedures (OPRIPALC) with the support of a dose management system for the protection of patients and staff.

IF 1.4 4区 环境科学与生态学 Q4 ENVIRONMENTAL SCIENCES
E Vano, J M Fernández-Soto, R M Sánchez-Casanueva, J I Ten Morón
{"title":"Improving a regional project on diagnostic reference levels for interventional procedures (OPRIPALC) with the support of a dose management system for the protection of patients and staff.","authors":"E Vano, J M Fernández-Soto, R M Sánchez-Casanueva, J I Ten Morón","doi":"10.1088/1361-6498/ad53d8","DOIUrl":null,"url":null,"abstract":"<p><p>Interventional radiology is a clinical practice with important benefits for patients, but which involves high radiation doses. The optimisation of radiation protection (RP) for paediatric interventional cardiology is a priority for both patients and staff. The use of diagnostic reference levels (DRLs) has been proposed by the International Commission on Radiological Protection to improve RP in imaging procedures. Dose management systems (DMSs) allow the automatic collection of dosimetric, geometric and technical data to assist the optimisation process, with a continuous audit of the procedures, generating alerts to implement corrective actions when necessary. Patient dose indicators may be analysed individually and for different radiation events (fluoroscopy and cine runs). Occupational doses per procedure may be analysed (if electronic dosimeters are available) and linked with patient doses for an integrated approach to RP. Regional optimisation programmes require data collection and processing from several countries to set and periodically update the DRLs. Patient data is anonymised, and each participating hospital has access to their data in a central computer server. Using DMSs may be one of the best ways to support these programs in the collection and analysis of data, raising alerts about high patient and occupational doses and suggesting optimisation actions.</p>","PeriodicalId":50068,"journal":{"name":"Journal of Radiological Protection","volume":" ","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2024-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiological Protection","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1088/1361-6498/ad53d8","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Interventional radiology is a clinical practice with important benefits for patients, but which involves high radiation doses. The optimisation of radiation protection (RP) for paediatric interventional cardiology is a priority for both patients and staff. The use of diagnostic reference levels (DRLs) has been proposed by the International Commission on Radiological Protection to improve RP in imaging procedures. Dose management systems (DMSs) allow the automatic collection of dosimetric, geometric and technical data to assist the optimisation process, with a continuous audit of the procedures, generating alerts to implement corrective actions when necessary. Patient dose indicators may be analysed individually and for different radiation events (fluoroscopy and cine runs). Occupational doses per procedure may be analysed (if electronic dosimeters are available) and linked with patient doses for an integrated approach to RP. Regional optimisation programmes require data collection and processing from several countries to set and periodically update the DRLs. Patient data is anonymised, and each participating hospital has access to their data in a central computer server. Using DMSs may be one of the best ways to support these programs in the collection and analysis of data, raising alerts about high patient and occupational doses and suggesting optimisation actions.

在剂量管理系统的支持下,改进介入程序诊断参考水平地区项目(OPRIPALC),以保护病人和工作人员。
介入放射学是一种对患者有重要益处的临床实践,但涉及高辐射剂量。优化儿科介入心脏病学的辐射防护对患者和工作人员来说都是当务之急。国际放射防护委员会建议使用诊断参考水平(DRLs)来改善成像程序中的辐射防护。剂量管理系统(DMS)可自动收集剂量测定、几何和技术数据,以协助优化过程,并对程序进行持续审核,在必要时发出警报以实施纠正措施。患者剂量指标可单独分析,也可针对不同的辐射事件(透视和电影运行)进行分析。可以分析每个程序的职业剂量(如果有电子剂量计),并将其与患者剂量联系起来,以综合的方式进行辐射防护。区域优化计划需要从多个国家收集和处理数据,以设定和定期更新 DRL。患者数据是匿名的,每家参与医院都可以在中央计算机服务器上访问其数据。使用剂量监测系统可能是支持这些计划的最佳方法之一,它可以收集和分析数据,对患者和职业人员的高剂量发出警报,并提出优化行动建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Radiological Protection
Journal of Radiological Protection 环境科学-公共卫生、环境卫生与职业卫生
CiteScore
2.60
自引率
26.70%
发文量
137
审稿时长
18-36 weeks
期刊介绍: Journal of Radiological Protection publishes articles on all aspects of radiological protection, including non-ionising as well as ionising radiations. Fields of interest range from research, development and theory to operational matters, education and training. The very wide spectrum of its topics includes: dosimetry, instrument development, specialized measuring techniques, epidemiology, biological effects (in vivo and in vitro) and risk and environmental impact assessments. The journal encourages publication of data and code as well as results.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信