Comparison of Short Curved Stems and Standard-length Single Wedged Stems for Cementless Total Hip Arthroplasty.

Chan Young Lee, Sheng-Yu Jin, Ji Hoon Choi, Taek-Rim Yoon, Kyung-Soon Park
{"title":"Comparison of Short Curved Stems and Standard-length Single Wedged Stems for Cementless Total Hip Arthroplasty.","authors":"Chan Young Lee, Sheng-Yu Jin, Ji Hoon Choi, Taek-Rim Yoon, Kyung-Soon Park","doi":"10.5371/hp.2024.36.2.120","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study was to compare the clinical and radiographic outcomes with use of short-curved stems versus standard-length single wedged stems over a minimum follow-up period of five years.</p><p><strong>Materials and methods: </strong>A retrospective study of primary total hip arthroplasties performed using the Fitmore<sup>®</sup> stem (127 hips, 122 patients) and the M/L taper<sup>®</sup> stem (195 hips, 187 patients) between October 2012 and June 2014 was conducted. The clinical and radiographic outcomes were obtained for evaluation over a minimum follow-up period of five years.</p><p><strong>Results: </strong>In both the Fitmore<sup>®</sup> and M/L taper<sup>®</sup> groups, the mean Harris hip score improved from 52.4 and 48.9 preoperatively to 93.3 and 94.5 at the final follow-up, respectively (<i>P</i>=0.980). The mean Western Ontario and McMaster Universities Osteoarthritis Index scores also improved from 73.3 and 76.8 preoperatively to 22.9 and 25.6 at the final follow-up, respectively (<i>P</i>=0.465). Fifteen hips (Fitmore<sup>®</sup>: 14 hips; M/L taper<sup>®</sup>: one hip, <i>P</i><0.001) developed intraoperative cracks and were treated simultaneously with cerclage wiring. Radiography showed a radiolucent line in 24 hips in the Fitmore<sup>®</sup> group and 12 hips in the M/L taper<sup>®</sup> group (<i>P</i>=0.125). Cortical hypertrophy was detected in 29 hips (Fitmore<sup>®</sup> group: 28 hips; M/L taper<sup>®</sup> group: one hip, <i>P</i><0.001).</p><p><strong>Conclusion: </strong>Similarly favorable clinical and radiographic outcomes were achieved with use of both short-curved stems and standard-length single wedged stems. However, higher cortical hypertrophy and a higher rate of femoral crack were observed with use of Fitmore<sup>®</sup> stems.</p>","PeriodicalId":73239,"journal":{"name":"Hip & pelvis","volume":"36 2","pages":"120-128"},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11162871/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hip & pelvis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5371/hp.2024.36.2.120","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The purpose of this study was to compare the clinical and radiographic outcomes with use of short-curved stems versus standard-length single wedged stems over a minimum follow-up period of five years.

Materials and methods: A retrospective study of primary total hip arthroplasties performed using the Fitmore® stem (127 hips, 122 patients) and the M/L taper® stem (195 hips, 187 patients) between October 2012 and June 2014 was conducted. The clinical and radiographic outcomes were obtained for evaluation over a minimum follow-up period of five years.

Results: In both the Fitmore® and M/L taper® groups, the mean Harris hip score improved from 52.4 and 48.9 preoperatively to 93.3 and 94.5 at the final follow-up, respectively (P=0.980). The mean Western Ontario and McMaster Universities Osteoarthritis Index scores also improved from 73.3 and 76.8 preoperatively to 22.9 and 25.6 at the final follow-up, respectively (P=0.465). Fifteen hips (Fitmore®: 14 hips; M/L taper®: one hip, P<0.001) developed intraoperative cracks and were treated simultaneously with cerclage wiring. Radiography showed a radiolucent line in 24 hips in the Fitmore® group and 12 hips in the M/L taper® group (P=0.125). Cortical hypertrophy was detected in 29 hips (Fitmore® group: 28 hips; M/L taper® group: one hip, P<0.001).

Conclusion: Similarly favorable clinical and radiographic outcomes were achieved with use of both short-curved stems and standard-length single wedged stems. However, higher cortical hypertrophy and a higher rate of femoral crack were observed with use of Fitmore® stems.

无骨水泥全髋关节置换术中短弯柄与标准长度单楔柄的比较
目的:本研究旨在比较使用短曲线柄与标准长度单楔柄在至少五年的随访期内的临床和放射学结果:对2012年10月至2014年6月期间使用Fitmore®柄(122例患者,127个髋关节)和M/L taper®柄(187例患者,195个髋关节)进行的初级全髋关节置换术进行了回顾性研究。结果显示,Fitmore®和M/L taper®两种人工髋关节置换术的临床和影像学结果均得到了至少五年的随访评估:Fitmore®组和M/L taper®组的平均Harris髋关节评分分别从术前的52.4分和48.9分提高到最终随访时的93.3分和94.5分(P=0.980)。西安大略和麦克马斯特大学骨关节炎指数的平均得分也分别从术前的 73.3 分和 76.8 分提高到最终随访时的 22.9 分和 25.6 分(P=0.465)。15 个髋关节(Fitmore®:14 个髋关节;M/L taper®:1 个髋关节,P® 组和 M/L taper® 组中的 12 个髋关节(P=0.125)。29 个髋关节(Fitmore® 组:28 个髋关节;M/L taper® 组:1 个髋关节,PC 结论)发现皮质肥厚:使用短曲线骨干和标准长度单楔形骨干都能获得类似良好的临床和影像学结果。但是,使用 Fitmore® 茎时,皮质肥厚程度更高,股骨裂缝发生率更高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.90
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信