Design and seismic performance analysis of a novel special-shaped steel tube concrete column steel beam joint

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS
Chun-yang Liu, Ji-he Qin, Zhen-fan Gong, Hao Wang, Guang-kai Zhou
{"title":"Design and seismic performance analysis of a novel special-shaped steel tube concrete column steel beam joint","authors":"Chun-yang Liu, Ji-he Qin, Zhen-fan Gong, Hao Wang, Guang-kai Zhou","doi":"10.1177/13694332241257648","DOIUrl":null,"url":null,"abstract":"In this study, a novel special-shaped steel tube concrete column steel beam joint is proposed. Bolt connections are used to connect the pre-welded steel beam and the special-shaped steel tube concrete column. Based on the finite element software ABAQUS, we established finite element models of the column-beam joints, and conducted a series of finite element analyses to investigate the influence of various parameters on the seismic performance of the joint. These parameters include the shape and size of the flange hole, the shape and size of the web hole, and thickness of the spliced plate on the flange. The results show that the difference between the finite element analysis and experimental results for bearing capacity and displacement is within 10%. This indicates that finite element analysis can be effectively utilized to study the seismic performance of the joint. Compared to joints with non-spliced beam, the rotational deformation capacity of the joint is reduced when using bolts and spliced plates designed by the equal-strength method. The energy dissipation capacity and ductility deformation capacity of the joints with spliced beams are significantly improved by using elliptical bolt holes in the flange, and plastic hinges are formed in the spliced region. The elliptical holes in the web with varying sizes have little effect on the seismic performance of the joint. The thicknesses of the spliced plate ranging from 6 mm to 8 mm has little effect on the seismic performance of the joint, and a thin spliced plate will reduce the seismic performance of the joint. The study presented in this paper can provide a reference for promoting the engineering application of special-shaped steel tube concrete structures.","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/13694332241257648","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, a novel special-shaped steel tube concrete column steel beam joint is proposed. Bolt connections are used to connect the pre-welded steel beam and the special-shaped steel tube concrete column. Based on the finite element software ABAQUS, we established finite element models of the column-beam joints, and conducted a series of finite element analyses to investigate the influence of various parameters on the seismic performance of the joint. These parameters include the shape and size of the flange hole, the shape and size of the web hole, and thickness of the spliced plate on the flange. The results show that the difference between the finite element analysis and experimental results for bearing capacity and displacement is within 10%. This indicates that finite element analysis can be effectively utilized to study the seismic performance of the joint. Compared to joints with non-spliced beam, the rotational deformation capacity of the joint is reduced when using bolts and spliced plates designed by the equal-strength method. The energy dissipation capacity and ductility deformation capacity of the joints with spliced beams are significantly improved by using elliptical bolt holes in the flange, and plastic hinges are formed in the spliced region. The elliptical holes in the web with varying sizes have little effect on the seismic performance of the joint. The thicknesses of the spliced plate ranging from 6 mm to 8 mm has little effect on the seismic performance of the joint, and a thin spliced plate will reduce the seismic performance of the joint. The study presented in this paper can provide a reference for promoting the engineering application of special-shaped steel tube concrete structures.
新型异形钢管混凝土柱钢梁接头的设计与抗震性能分析
本研究提出了一种新型异形钢管混凝土柱钢梁连接方式。预焊接钢梁和异型钢管混凝土柱之间采用螺栓连接。基于有限元软件 ABAQUS,我们建立了柱梁接头的有限元模型,并进行了一系列有限元分析,以研究各种参数对接头抗震性能的影响。这些参数包括翼缘孔的形状和尺寸、腹板孔的形状和尺寸以及翼缘上拼接板的厚度。结果表明,在承载力和位移方面,有限元分析和实验结果的差异在 10%以内。这表明可以有效地利用有限元分析来研究接头的抗震性能。与不拼接梁的连接相比,采用等强度方法设计的螺栓和拼接板的连接旋转变形能力降低。通过在翼缘板上使用椭圆形螺栓孔,并在拼接区域形成塑性铰链,拼接梁接头的消能能力和延性变形能力显著提高。腹板上不同尺寸的椭圆孔对连接的抗震性能影响不大。拼接板的厚度从 6 毫米到 8 毫米不等,对连接件的抗震性能影响不大,而薄的拼接板会降低连接件的抗震性能。本文的研究可为促进异型钢管混凝土结构的工程应用提供参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信