Prospective observational cohort study of the change of the marginal bone crest in relation to the prosthetic abutment height and the peri-implant vertical mucosal thickness at implants positioned subcrestally
{"title":"Prospective observational cohort study of the change of the marginal bone crest in relation to the prosthetic abutment height and the peri-implant vertical mucosal thickness at implants positioned subcrestally","authors":"Serafín Maza-Solano DDS, María Baus-Domínguez DDS, Manuel-María Romero-Ruíz DMD, PhD, Aida Gutiérrez-Corrales DDS, PhD, Daniel Torres-Lagares DDS, PhD, María-Ángeles Serrera-Figallo DDS, PhD","doi":"10.1111/cid.13347","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Aim</h3>\n \n <p>To evaluate the influence on peri-implant crestal bone loss exerted by the vertical mucosal thickness and the abutment height over 12 months after placement of the restoration on subcrestal implants with change of platform, using a restoration abutment platform smaller than the implant platform.</p>\n </section>\n \n <section>\n \n <h3> Materials and Methods</h3>\n \n <p>A total of 99 implants were rehabilitated in the maxillary and mandibular posterior regions. A total of 22 implants were rehabilitated in the maxilla and 77 implants in the mandible, using digitally designed customized abutments with Atlantis weborder software, from the commercial house Dentsply Sirona (Dentsply Sirona S.A., Barcelona, Spain), version 4.6.5, adapting the height to the vertical thickness of the mucosa. Clinical and radiographic monitoring begins during the surgical procedure of placement of the implant and ends 12 months afterwards. Crestal bone loss was evaluated through the Carestream® CS8100 3D radiographic equipment.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>In all cases, the greatest loss of marginal bone occurred between the day of surgery (Tx) and placement of the rehabilitation (To). The average bone loss between both times was greater when the abutment height and vertical mucosal thickness did not exceed 3 mm. Subsequently, bone loss slowed and stabilized at 12 months.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The minimum abutment height and the vertical mucosal thickness are factors to take into account when minimizing peri-implant marginal bone loss, the abutment height having the greatest importance according to the clinical data obtained.</p>\n </section>\n </div>","PeriodicalId":50679,"journal":{"name":"Clinical Implant Dentistry and Related Research","volume":"26 4","pages":"750-762"},"PeriodicalIF":3.7000,"publicationDate":"2024-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/cid.13347","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Implant Dentistry and Related Research","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/cid.13347","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Aim
To evaluate the influence on peri-implant crestal bone loss exerted by the vertical mucosal thickness and the abutment height over 12 months after placement of the restoration on subcrestal implants with change of platform, using a restoration abutment platform smaller than the implant platform.
Materials and Methods
A total of 99 implants were rehabilitated in the maxillary and mandibular posterior regions. A total of 22 implants were rehabilitated in the maxilla and 77 implants in the mandible, using digitally designed customized abutments with Atlantis weborder software, from the commercial house Dentsply Sirona (Dentsply Sirona S.A., Barcelona, Spain), version 4.6.5, adapting the height to the vertical thickness of the mucosa. Clinical and radiographic monitoring begins during the surgical procedure of placement of the implant and ends 12 months afterwards. Crestal bone loss was evaluated through the Carestream® CS8100 3D radiographic equipment.
Results
In all cases, the greatest loss of marginal bone occurred between the day of surgery (Tx) and placement of the rehabilitation (To). The average bone loss between both times was greater when the abutment height and vertical mucosal thickness did not exceed 3 mm. Subsequently, bone loss slowed and stabilized at 12 months.
Conclusions
The minimum abutment height and the vertical mucosal thickness are factors to take into account when minimizing peri-implant marginal bone loss, the abutment height having the greatest importance according to the clinical data obtained.
期刊介绍:
The goal of Clinical Implant Dentistry and Related Research is to advance the scientific and technical aspects relating to dental implants and related scientific subjects. Dissemination of new and evolving information related to dental implants and the related science is the primary goal of our journal.
The range of topics covered by the journals will include but be not limited to:
New scientific developments relating to bone
Implant surfaces and their relationship to the surrounding tissues
Computer aided implant designs
Computer aided prosthetic designs
Immediate implant loading
Immediate implant placement
Materials relating to bone induction and conduction
New surgical methods relating to implant placement
New materials and methods relating to implant restorations
Methods for determining implant stability
A primary focus of the journal is publication of evidenced based articles evaluating to new dental implants, techniques and multicenter studies evaluating these treatments. In addition basic science research relating to wound healing and osseointegration will be an important focus for the journal.