[Dynamic monitoring and esthetic evaluation of dimensional changes in the peri-implant soft tissue contour after the immediate implant placement and provisionalization with the modified socket-shield technique in the esthetic zone].

Q4 Medicine
X F Tang, Q Q Wu, X Chen, Y Wang, G Fu
{"title":"[Dynamic monitoring and esthetic evaluation of dimensional changes in the peri-implant soft tissue contour after the immediate implant placement and provisionalization with the modified socket-shield technique in the esthetic zone].","authors":"X F Tang, Q Q Wu, X Chen, Y Wang, G Fu","doi":"10.3760/cma.j.cn112144-20240215-00072","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> To accurately measure the dynamic changes of peri-implant soft tissue within one year after the immediate implant placement and provisionalization with the modified socket-shield technique (MSST) in the esthetic zone, and to provide a basis for evaluating the effect of the modified socket-shield technique on the maintenance of peri-implant soft tissue. <b>Methods:</b> A total of 22 patients (22 implants) were prospectively included 1 year after completion of immediate implant placement and provisionalization (IIPP) within MSST in the esthetic zone from January 2022 to January 2024 at the Department of Oral Implantology in the Stomatological Hospital of Chongqing Medical University. The intraoral optical models of patients were obtained by an intraoral scanner system preoperatively and at 3, 6, and 12 months postoperatively, respectively. The standard tessellation language files of intraoral optical models at multiple time points were imported to Geomagic Studio 2013 to be superimposed and aligned for analyzing the peri-implant soft tissue contour on the labial side of the implant site at multiple levels. The amount of gingival margin recession, gingival papilla change, and thickness change of the labial side of the soft tissues at each postoperative point in time were measured at each postoperative time point, as well as evaluating the esthetic effect by the pink esthetic score (PES). <b>Results:</b> The patients were (40±13) years old (21-75 years), including 9 males and 13 females. No adverse events occurred in all the implants during the 12-month follow-up period. The recession level of the gingival margin of the implant site (GL) was 0.08 (0.07) mm, the recession level of the mesial papilla (ML) was 0.19 (0.25) mm, and the recession level of the distal papilla (DL) was 0.19 (0.10) mm. The average collapse thickness of the soft tissue contour on the labial side of the implant (ΔD) was (0.39±0.09) mm, mainly occurring within 2 mm of the root of the gingival margin. The height of the alveolar bone was reduced by (0.17±0.08) mm. The thickness of the labial alveolar bone at 1, 3, and 5 mm root side of the implant shoulder was reduced by (0.13±0.08), (0.12±0.10) and 0.04 (0.17) mm, respectively. The postoperative pink esthetic score was 13.00 (2.25) points at 12 months, which suggested that all implant sites achieved ideal esthetic results. <b>Conclusions:</b> The labial soft tissue contour at implant sites shows minimal change following immediate implant placement and provisionalization using the modified socket-shield technique for 1 year in the esthetic zone.</p>","PeriodicalId":23965,"journal":{"name":"中华口腔医学杂志","volume":"59 6","pages":"551-558"},"PeriodicalIF":0.0000,"publicationDate":"2024-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华口腔医学杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/cma.j.cn112144-20240215-00072","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To accurately measure the dynamic changes of peri-implant soft tissue within one year after the immediate implant placement and provisionalization with the modified socket-shield technique (MSST) in the esthetic zone, and to provide a basis for evaluating the effect of the modified socket-shield technique on the maintenance of peri-implant soft tissue. Methods: A total of 22 patients (22 implants) were prospectively included 1 year after completion of immediate implant placement and provisionalization (IIPP) within MSST in the esthetic zone from January 2022 to January 2024 at the Department of Oral Implantology in the Stomatological Hospital of Chongqing Medical University. The intraoral optical models of patients were obtained by an intraoral scanner system preoperatively and at 3, 6, and 12 months postoperatively, respectively. The standard tessellation language files of intraoral optical models at multiple time points were imported to Geomagic Studio 2013 to be superimposed and aligned for analyzing the peri-implant soft tissue contour on the labial side of the implant site at multiple levels. The amount of gingival margin recession, gingival papilla change, and thickness change of the labial side of the soft tissues at each postoperative point in time were measured at each postoperative time point, as well as evaluating the esthetic effect by the pink esthetic score (PES). Results: The patients were (40±13) years old (21-75 years), including 9 males and 13 females. No adverse events occurred in all the implants during the 12-month follow-up period. The recession level of the gingival margin of the implant site (GL) was 0.08 (0.07) mm, the recession level of the mesial papilla (ML) was 0.19 (0.25) mm, and the recession level of the distal papilla (DL) was 0.19 (0.10) mm. The average collapse thickness of the soft tissue contour on the labial side of the implant (ΔD) was (0.39±0.09) mm, mainly occurring within 2 mm of the root of the gingival margin. The height of the alveolar bone was reduced by (0.17±0.08) mm. The thickness of the labial alveolar bone at 1, 3, and 5 mm root side of the implant shoulder was reduced by (0.13±0.08), (0.12±0.10) and 0.04 (0.17) mm, respectively. The postoperative pink esthetic score was 13.00 (2.25) points at 12 months, which suggested that all implant sites achieved ideal esthetic results. Conclusions: The labial soft tissue contour at implant sites shows minimal change following immediate implant placement and provisionalization using the modified socket-shield technique for 1 year in the esthetic zone.

[在美学区使用改良的牙槽盾技术即刻植入种植体并进行临时修复后,对种植体周围软组织轮廓的尺寸变化进行动态监测和美学评估]。
目的精确测量即刻种植体植入后一年内种植体周围软组织的动态变化,并为评估改良式基台屏蔽技术(MSST)对种植体周围软组织的维护效果提供依据。研究方法前瞻性纳入2022年1月至2024年1月在重庆医科大学附属口腔医院口腔种植科完成美学区MSST即刻种植体植入和临时修复(IIPP)1年后的22例患者(22颗种植体)。患者年龄(40±13)岁(21-75 岁),其中男性 9 人,女性 13 人。患者的口内光学模型分别在术前和术后3、6、12个月时通过口内扫描系统获得。将多个时间点的口内光学模型的标准细分语言文件导入 Geomagic Studio 2013 进行叠加和对齐,以分析种植部位唇侧多个层次的种植体周围软组织轮廓。测量术后各时间点的龈缘退缩量、龈乳头变化和唇侧软组织厚度变化,并通过粉色美学评分(PES)评估美学效果。结果在 12 个月的随访期间,所有种植体均未发生不良反应。种植部位龈缘的退缩水平(GL)为 0.08(0.07)毫米,中侧乳头的退缩水平(ML)为 0.19(0.25)毫米,远侧乳头的退缩水平(DL)为 0.19(0.10)毫米。种植体唇侧软组织轮廓的平均塌陷厚度(ΔD)为(0.39±0.09)毫米,主要发生在龈缘根部 2 毫米范围内。牙槽骨高度降低了(0.17±0.08)毫米。种植体肩部根侧 1、3 和 5 毫米处的唇侧牙槽骨厚度分别减少了(0.13±0.08)、(0.12±0.10)和 0.04 (0.17) 毫米。术后 12 个月的粉色美学评分为 13.00(2.25)分,这表明所有种植部位都达到了理想的美学效果。结论使用改良的窝沟封闭技术即刻植入种植体并临时修复一年后,种植部位的唇软组织轮廓在美学区域的变化很小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
中华口腔医学杂志
中华口腔医学杂志 Medicine-Medicine (all)
CiteScore
0.90
自引率
0.00%
发文量
9692
期刊介绍: Founded in August 1953, Chinese Journal of Stomatology is a monthly academic journal of stomatology published publicly at home and abroad, sponsored by the Chinese Medical Association and co-sponsored by the Chinese Stomatology Association. It mainly reports the leading scientific research results and clinical diagnosis and treatment experience in the field of oral medicine, as well as the basic theoretical research that has a guiding role in oral clinical practice and is closely combined with oral clinical practice. Chinese Journal of Over the years, Stomatology has been published in Medline, Scopus database, Toxicology Abstracts Database, Chemical Abstracts Database, American Cancer database, Russian Abstracts database, China Core Journal of Science and Technology, Peking University Core Journal, CSCD and other more than 20 important journals at home and abroad Physical medicine database and retrieval system included.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信