Chest x-ray has low sensitivity to detect silicosis in artificial stone benchtop industry workers.

IF 6.6 2区 医学 Q1 RESPIRATORY SYSTEM
Respirology Pub Date : 2024-09-01 Epub Date: 2024-05-27 DOI:10.1111/resp.14755
Ryan F Hoy, Catherine Jones, Katrina Newbigin, Michael J Abramson, Hayley Barnes, Christina Dimitriadis, Samantha Ellis, Deborah C Glass, Stella M Gwini, Fiona Hore-Lacy, Javier Jimenez-Martin, Sundeep S Pasricha, Janu Pirakalathanan, Miranda Siemienowicz, Karen Walker-Bone, Malcolm R Sim
{"title":"Chest x-ray has low sensitivity to detect silicosis in artificial stone benchtop industry workers.","authors":"Ryan F Hoy, Catherine Jones, Katrina Newbigin, Michael J Abramson, Hayley Barnes, Christina Dimitriadis, Samantha Ellis, Deborah C Glass, Stella M Gwini, Fiona Hore-Lacy, Javier Jimenez-Martin, Sundeep S Pasricha, Janu Pirakalathanan, Miranda Siemienowicz, Karen Walker-Bone, Malcolm R Sim","doi":"10.1111/resp.14755","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objective: </strong>Chest x-ray (CXR) remains a core component of health monitoring guidelines for workers at risk of exposure to crystalline silica. There has however been a lack of evidence regarding the sensitivity of CXR to detect silicosis in artificial stone benchtop industry workers.</p><p><strong>Methods: </strong>Paired CXR and high-resolution computed tomography (HRCT) images were acquired from 110 artificial stone benchtop industry workers. Blinded to the clinical diagnosis, each CXR and HRCT was independently read by two thoracic radiologists from a panel of seven, in accordance with International Labour Office (ILO) methodology for CXR and International Classification of HRCT for Occupational and Environmental Respiratory Diseases. Accuracy of screening positive (ILO major category 1, 2 or 3) and negative (ILO major category 0) CXRs were compared with identification of radiological features of silicosis on HRCT.</p><p><strong>Results: </strong>CXR was positive for silicosis in 27/110 (24.5%) workers and HRCT in 40/110 (36.4%). Of the 83 with a negative CXR (ILO category 0), 15 (18.1%) had silicosis on HRCT. All 11 workers with ILO category 2 or 3 CXRs had silicosis on HRCT. In 99 workers ILO category 0 or 1 CXRs, the sensitivity of screening positive CXR compared to silicosis identified by HRCT was 48% (95%CI 29-68) and specificity 97% (90-100).</p><p><strong>Conclusion: </strong>Compared to HRCT, sensitivity of CXR was low but specificity was high. Reliance on CXR for health monitoring would provide false reassurance for many workers, delay management and underestimate the prevalence of silicosis in the artificial stone benchtop industry.</p>","PeriodicalId":21129,"journal":{"name":"Respirology","volume":" ","pages":"785-794"},"PeriodicalIF":6.6000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Respirology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/resp.14755","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/27 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0

Abstract

Background and objective: Chest x-ray (CXR) remains a core component of health monitoring guidelines for workers at risk of exposure to crystalline silica. There has however been a lack of evidence regarding the sensitivity of CXR to detect silicosis in artificial stone benchtop industry workers.

Methods: Paired CXR and high-resolution computed tomography (HRCT) images were acquired from 110 artificial stone benchtop industry workers. Blinded to the clinical diagnosis, each CXR and HRCT was independently read by two thoracic radiologists from a panel of seven, in accordance with International Labour Office (ILO) methodology for CXR and International Classification of HRCT for Occupational and Environmental Respiratory Diseases. Accuracy of screening positive (ILO major category 1, 2 or 3) and negative (ILO major category 0) CXRs were compared with identification of radiological features of silicosis on HRCT.

Results: CXR was positive for silicosis in 27/110 (24.5%) workers and HRCT in 40/110 (36.4%). Of the 83 with a negative CXR (ILO category 0), 15 (18.1%) had silicosis on HRCT. All 11 workers with ILO category 2 or 3 CXRs had silicosis on HRCT. In 99 workers ILO category 0 or 1 CXRs, the sensitivity of screening positive CXR compared to silicosis identified by HRCT was 48% (95%CI 29-68) and specificity 97% (90-100).

Conclusion: Compared to HRCT, sensitivity of CXR was low but specificity was high. Reliance on CXR for health monitoring would provide false reassurance for many workers, delay management and underestimate the prevalence of silicosis in the artificial stone benchtop industry.

胸部 X 射线对人造石台面行业工人矽肺病的检测灵敏度较低。
背景和目的:胸部 X 光(CXR)仍然是健康监测指南的核心组成部分,适用于有接触结晶二氧化硅风险的工人。然而,在人造石台面行业工人的矽肺病检测中,CXR 的灵敏度一直缺乏证据:方法:对 110 名人造石台面业工人进行了成对的 CXR 和高分辨率计算机断层扫描(HRCT)成像。根据国际劳工局(ILO)的 CXR 方法和职业与环境呼吸系统疾病 HRCT 国际分类,每张 CXR 和 HRCT 均由 7 人小组中的两名胸部放射科医生独立阅读,并对临床诊断结果保密。将筛查阳性(国际劳工组织主要分类 1、2 或 3)和阴性(国际劳工组织主要分类 0)CXR 的准确性与 HRCT 对矽肺放射学特征的识别进行了比较:结果:27/110(24.5%)名工人的气管造影呈矽肺阳性,40/110(36.4%)名工人的 HRCT 呈矽肺阳性。在 83 名 CXR 阴性(ILO 0 类)的工人中,有 15 人(18.1%)的 HRCT 检测结果为矽肺。所有 11 名 ILO 2 类或 3 类 CXR 的工人在 HRCT 检测中均患有矽肺病。在 99 名 ILO 类别 0 或 1 CXR 的工人中,与 HRCT 鉴定出的矽肺相比,筛查阳性 CXR 的灵敏度为 48% (95%CI 29-68),特异性为 97% (90-100):结论:与 HRCT 相比,CXR 的敏感性较低,但特异性较高。依赖 CXR 进行健康监测会给许多工人带来错误的保证,延误管理,并低估人造石台面行业中矽肺病的发病率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Respirology
Respirology 医学-呼吸系统
CiteScore
10.60
自引率
5.80%
发文量
225
审稿时长
1 months
期刊介绍: Respirology is a journal of international standing, publishing peer-reviewed articles of scientific excellence in clinical and clinically-relevant experimental respiratory biology and disease. Fields of research include immunology, intensive and critical care, epidemiology, cell and molecular biology, pathology, pharmacology, physiology, paediatric respiratory medicine, clinical trials, interventional pulmonology and thoracic surgery. The Journal aims to encourage the international exchange of results and publishes papers in the following categories: Original Articles, Editorials, Reviews, and Correspondences. Respirology is the preferred journal of the Thoracic Society of Australia and New Zealand, has been adopted as the preferred English journal of the Japanese Respiratory Society and the Taiwan Society of Pulmonary and Critical Care Medicine and is an official journal of the World Association for Bronchology and Interventional Pulmonology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信