{"title":"Inter-rater-reliability, intra-rater-reliability and validity of clinical tests to assess cervical spine motor control abilities: A systematic review of diagnostic accuracy studies","authors":"Bernard Engelmann , Jacob Marten Switters , Hannu Luomajoki","doi":"10.1016/j.jbmt.2024.01.026","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Research into the aetiology of spinal pain has shown a clear tendency towards a sensorimotor control perspective. In contrast to the lumbar spine, the available motor control tests for the cervical spine are extremely varied, little studied and sometimes very costly.</p></div><div><h3>Objective</h3><p>Review the quality and choice of the available cervical spine motor control tests. The diagnostic accuracy of the current low technology motor control tests was evaluated in a systematic review.</p></div><div><h3>Method</h3><p>A search for reliability and discriminative validity studies was conducted in the Pubmed MEDLINE® database (NCBI) and the Cochrane Central Register of Controlled Trials, according to the PRISMA–DTA protocol. Quality Appraisal for Reliability Studies (QAREL) and Standards for Reporting Diagnostic accuracy studies (STARD) were conducted to assess the quality of the included studies. The statistical parameters of ICC, kappa-value, sensitivity, specificity, Diagnostic Odds Ratio, Area Under the Curve, mean, standard deviation and/or the confidence interval were extracted.</p></div><div><h3>Results</h3><p>Two movement control test batteries, one head-eye-coordination test battery and the craniocervical flexion test were found to be standing out in terms of reliability, validity, applicability and cost-effectiveness (Kappa and ICC scores >0.8 for reliability and AUC 0,83 for validity.)</p></div><div><h3>Discussion</h3><p>To date only one study was published for each of the test batteries. Nevertheless, the risk of bias compared to all other cervical motor control tests found was significantly lower. Moreover, the application is possible completely without technical equipment, which makes the findings of the present work accessible to the majority of healthcare professionals.</p></div>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1360859224000408","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Research into the aetiology of spinal pain has shown a clear tendency towards a sensorimotor control perspective. In contrast to the lumbar spine, the available motor control tests for the cervical spine are extremely varied, little studied and sometimes very costly.
Objective
Review the quality and choice of the available cervical spine motor control tests. The diagnostic accuracy of the current low technology motor control tests was evaluated in a systematic review.
Method
A search for reliability and discriminative validity studies was conducted in the Pubmed MEDLINE® database (NCBI) and the Cochrane Central Register of Controlled Trials, according to the PRISMA–DTA protocol. Quality Appraisal for Reliability Studies (QAREL) and Standards for Reporting Diagnostic accuracy studies (STARD) were conducted to assess the quality of the included studies. The statistical parameters of ICC, kappa-value, sensitivity, specificity, Diagnostic Odds Ratio, Area Under the Curve, mean, standard deviation and/or the confidence interval were extracted.
Results
Two movement control test batteries, one head-eye-coordination test battery and the craniocervical flexion test were found to be standing out in terms of reliability, validity, applicability and cost-effectiveness (Kappa and ICC scores >0.8 for reliability and AUC 0,83 for validity.)
Discussion
To date only one study was published for each of the test batteries. Nevertheless, the risk of bias compared to all other cervical motor control tests found was significantly lower. Moreover, the application is possible completely without technical equipment, which makes the findings of the present work accessible to the majority of healthcare professionals.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.