{"title":"An Experimental Study for Air Temperature Distribution in a Conditioned Room Using Various Vertical Locations of Conditioned Air Ducts","authors":"Sunil M Mahajan, V. Bartaria","doi":"10.12944/cwe.19.1.39","DOIUrl":null,"url":null,"abstract":"The Air distribution phenomenon is most useful in thermal environment study and its effectiveness. The main aim of this investigation is to examine and discover the thermal properties of the inside area and its thermal environment. The experimental work for research was studied at the first-floor lab of the government women’s polytechnic, Bhopal. The experiment was conducted in the summer and winter seasons in a closed-conditioned room with the arrangement of a conditioned air discharge duct. The conditioned air was discharged through the circular pipe duct which was set vertically. The duct has arrangements to discharge the air through various vertical positions as the lower duct (L), middle duct (M), and upper duct (U). This experimental work investigates supply air velocity and vertical temperature variation effectiveness inside said test room. The experiment results were collected with lower, middle, and vertical duct opening conditions respectively. The vertical temperature variation and air velocity at the outlet of the duct were noted with considerable points at 1 m from each inside the test room space. The outcome of the results shows the indoor thermal environment and vertical temperature distribution were affected by the discharge air duct position and supply air velocity. The temperature profile vertically impacted when the measuring test point position was near the discharge air duct and it became quite consistent in respective measurements from a large distance.","PeriodicalId":10878,"journal":{"name":"Current World Environment","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current World Environment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12944/cwe.19.1.39","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The Air distribution phenomenon is most useful in thermal environment study and its effectiveness. The main aim of this investigation is to examine and discover the thermal properties of the inside area and its thermal environment. The experimental work for research was studied at the first-floor lab of the government women’s polytechnic, Bhopal. The experiment was conducted in the summer and winter seasons in a closed-conditioned room with the arrangement of a conditioned air discharge duct. The conditioned air was discharged through the circular pipe duct which was set vertically. The duct has arrangements to discharge the air through various vertical positions as the lower duct (L), middle duct (M), and upper duct (U). This experimental work investigates supply air velocity and vertical temperature variation effectiveness inside said test room. The experiment results were collected with lower, middle, and vertical duct opening conditions respectively. The vertical temperature variation and air velocity at the outlet of the duct were noted with considerable points at 1 m from each inside the test room space. The outcome of the results shows the indoor thermal environment and vertical temperature distribution were affected by the discharge air duct position and supply air velocity. The temperature profile vertically impacted when the measuring test point position was near the discharge air duct and it became quite consistent in respective measurements from a large distance.