Synchrotron Analysis of Damaged Extraction Sockets Augmented Using a Synthetic Bone Block: A Pilot Study.

Jin-Young Park, Joo-Yeon Lee, Shinyoung Park, Jae-Kook Cha, Jung-Seok Lee, Ui-Won Jung
{"title":"Synchrotron Analysis of Damaged Extraction Sockets Augmented Using a Synthetic Bone Block: A Pilot Study.","authors":"Jin-Young Park, Joo-Yeon Lee, Shinyoung Park, Jae-Kook Cha, Jung-Seok Lee, Ui-Won Jung","doi":"10.11607/prd.6468","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to investigate the dimensional stability and quality of the alveolar ridge augmented using a synthetic bone block (SBB) at damaged extraction sockets. Four participants were included, and socket augmentation was performed using SBB and a collagen membrane. Intraoral and CBCT scans were performed before extraction (baseline), immediately postoperative (IP), and at 6 months postoperative (6M). At 6M, a trephine biopsy sample was obtained during implant placement, and the sample was observed using synchrotron. Soft tissue profile changes were assessed using profilometric analysis of the intraoral scan data, while dimensional changes in hard tissue were evaluated based on CBCT measurements. Bone quality was analyzed using synchrotron imaging. There were minimal changes in the soft tissue profile between baseline and IP, baseline and 6M, and IP and 6M (0.11 ± 1.08 mm3, 0.02 ± 0.8 mm3, and -0.65 ± 0.82 mm3, respectively). Horizontal bone width was measured at 1-mm increments from the augmented bone crest to 5 mm apically and revealed only a slight reduction (< 1 mm) at all levels between IP and 6M. The augmented bone height was well maintained from IP until 6M (-0.21 ± 0.53 mm). Synchrotron analysis revealed low to moderate bone quality after 6M (percentage of new bone: 16.49% ± 4.91%). Socket augmentation using SBB appears to be a viable technique for regenerating damaged extraction sockets, with the augmented ridge dimensions maintained up to 6M. Further long-term randomized clinical trials are needed.</p>","PeriodicalId":94231,"journal":{"name":"The International journal of periodontics & restorative dentistry","volume":"44 3","pages":"299-307"},"PeriodicalIF":0.0000,"publicationDate":"2024-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of periodontics & restorative dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/prd.6468","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/8 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This study aimed to investigate the dimensional stability and quality of the alveolar ridge augmented using a synthetic bone block (SBB) at damaged extraction sockets. Four participants were included, and socket augmentation was performed using SBB and a collagen membrane. Intraoral and CBCT scans were performed before extraction (baseline), immediately postoperative (IP), and at 6 months postoperative (6M). At 6M, a trephine biopsy sample was obtained during implant placement, and the sample was observed using synchrotron. Soft tissue profile changes were assessed using profilometric analysis of the intraoral scan data, while dimensional changes in hard tissue were evaluated based on CBCT measurements. Bone quality was analyzed using synchrotron imaging. There were minimal changes in the soft tissue profile between baseline and IP, baseline and 6M, and IP and 6M (0.11 ± 1.08 mm3, 0.02 ± 0.8 mm3, and -0.65 ± 0.82 mm3, respectively). Horizontal bone width was measured at 1-mm increments from the augmented bone crest to 5 mm apically and revealed only a slight reduction (< 1 mm) at all levels between IP and 6M. The augmented bone height was well maintained from IP until 6M (-0.21 ± 0.53 mm). Synchrotron analysis revealed low to moderate bone quality after 6M (percentage of new bone: 16.49% ± 4.91%). Socket augmentation using SBB appears to be a viable technique for regenerating damaged extraction sockets, with the augmented ridge dimensions maintained up to 6M. Further long-term randomized clinical trials are needed.

使用合成骨块对受损的拔牙套筒进行同步加速器分析:试点研究。
本研究旨在探讨在受损的拔牙窝中使用合成骨块(SBB)扩增牙槽嵴的尺寸稳定性和质量。研究共纳入了四名参与者,并使用 SBB 和胶原膜进行了牙槽窝增量。分别在拔牙前(基线)、术后即刻(IP)和术后 6 个月(6M)进行了口内和 CBCT 扫描。术后 6 个月时,在植入种植体时进行了取样活检,并使用同步加速器对样本进行了观察。口内扫描数据的轮廓分析评估了软组织轮廓的变化,CBCT 测量则评估了硬组织的尺寸变化。骨骼质量则通过同步加速器成像进行分析。基线与 IP、基线与 6M、IP 与 6M 之间的软组织轮廓变化极小(分别为 0.11 ± 1.08 mm3、0.02 ± 0.8 mm3 和 -0.65 ± 0.82 mm3)。水平骨宽度的测量以 1 毫米为增量,从增高的骨嵴到根尖 5 毫米,结果显示,在 IP 和 6M 之间的所有水平上,水平骨宽度都略有减少(< 1 毫米)。从 IP 到 6M 期间,增高的骨高度保持良好(-0.21 ± 0.53 mm)。同步加速器分析显示,6M后的骨质量为中低水平(新骨百分比:16.49% ± 4.91%)。使用 SBB 进行牙槽窝增量似乎是一种可行的技术,可以使受损的拔牙槽窝再生,增量后的牙脊尺寸可以保持到 6 个月。还需要进一步的长期随机临床试验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信