Jin-Young Park, Joo-Yeon Lee, Shinyoung Park, Jae-Kook Cha, Jung-Seok Lee, Ui-Won Jung
{"title":"Synchrotron Analysis of Damaged Extraction Sockets Augmented Using a Synthetic Bone Block: A Pilot Study.","authors":"Jin-Young Park, Joo-Yeon Lee, Shinyoung Park, Jae-Kook Cha, Jung-Seok Lee, Ui-Won Jung","doi":"10.11607/prd.6468","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to investigate the dimensional stability and quality of the alveolar ridge augmented using a synthetic bone block (SBB) at damaged extraction sockets. Four participants were included, and socket augmentation was performed using SBB and a collagen membrane. Intraoral and CBCT scans were performed before extraction (baseline), immediately postoperative (IP), and at 6 months postoperative (6M). At 6M, a trephine biopsy sample was obtained during implant placement, and the sample was observed using synchrotron. Soft tissue profile changes were assessed using profilometric analysis of the intraoral scan data, while dimensional changes in hard tissue were evaluated based on CBCT measurements. Bone quality was analyzed using synchrotron imaging. There were minimal changes in the soft tissue profile between baseline and IP, baseline and 6M, and IP and 6M (0.11 ± 1.08 mm3, 0.02 ± 0.8 mm3, and -0.65 ± 0.82 mm3, respectively). Horizontal bone width was measured at 1-mm increments from the augmented bone crest to 5 mm apically and revealed only a slight reduction (< 1 mm) at all levels between IP and 6M. The augmented bone height was well maintained from IP until 6M (-0.21 ± 0.53 mm). Synchrotron analysis revealed low to moderate bone quality after 6M (percentage of new bone: 16.49% ± 4.91%). Socket augmentation using SBB appears to be a viable technique for regenerating damaged extraction sockets, with the augmented ridge dimensions maintained up to 6M. Further long-term randomized clinical trials are needed.</p>","PeriodicalId":94231,"journal":{"name":"The International journal of periodontics & restorative dentistry","volume":"44 3","pages":"299-307"},"PeriodicalIF":0.0000,"publicationDate":"2024-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of periodontics & restorative dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/prd.6468","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/8 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This study aimed to investigate the dimensional stability and quality of the alveolar ridge augmented using a synthetic bone block (SBB) at damaged extraction sockets. Four participants were included, and socket augmentation was performed using SBB and a collagen membrane. Intraoral and CBCT scans were performed before extraction (baseline), immediately postoperative (IP), and at 6 months postoperative (6M). At 6M, a trephine biopsy sample was obtained during implant placement, and the sample was observed using synchrotron. Soft tissue profile changes were assessed using profilometric analysis of the intraoral scan data, while dimensional changes in hard tissue were evaluated based on CBCT measurements. Bone quality was analyzed using synchrotron imaging. There were minimal changes in the soft tissue profile between baseline and IP, baseline and 6M, and IP and 6M (0.11 ± 1.08 mm3, 0.02 ± 0.8 mm3, and -0.65 ± 0.82 mm3, respectively). Horizontal bone width was measured at 1-mm increments from the augmented bone crest to 5 mm apically and revealed only a slight reduction (< 1 mm) at all levels between IP and 6M. The augmented bone height was well maintained from IP until 6M (-0.21 ± 0.53 mm). Synchrotron analysis revealed low to moderate bone quality after 6M (percentage of new bone: 16.49% ± 4.91%). Socket augmentation using SBB appears to be a viable technique for regenerating damaged extraction sockets, with the augmented ridge dimensions maintained up to 6M. Further long-term randomized clinical trials are needed.