Antigoni Sakellaropoulou, Georgios Giannopoulos, Dimitrios Tachmatzidis, Konstantinos P Letsas, Antonios Antoniadis, Dimitrios Asvestas, Dimitrios Filos, Panagiotis Mililis, Michael Efremidis, Ioanna Chouvarda, Vassilios P Vassilikos
{"title":"Association of beat-to-beat P-wave analysis index to the extent of left atrial low-voltage areas in patients with paroxysmal atrial fibrillation.","authors":"Antigoni Sakellaropoulou, Georgios Giannopoulos, Dimitrios Tachmatzidis, Konstantinos P Letsas, Antonios Antoniadis, Dimitrios Asvestas, Dimitrios Filos, Panagiotis Mililis, Michael Efremidis, Ioanna Chouvarda, Vassilios P Vassilikos","doi":"10.1016/j.hjc.2024.05.011","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Left atrial (LA) fibrosis has been shown to be associated with atrial fibrillation (AF) recurrence. Beat-to-beat (B2B) index is a non-invasive classifier, based on B2B P-wave morphological and wavelet analysis, shown to be associated with AF incidence and recurrence. In this study, we tested the hypothesis that the B2B index is associated with the extent of LA low-voltage areas (LVAs) on electroanatomical mapping.</p><p><strong>Methods: </strong>Patients with paroxysmal AF scheduled for pulmonary vein isolation, without evident structural remodeling, were included. Pre-ablation electroanatomical voltage maps were used to calculate the surface of LVAs (<0.5 mV). B2B index was compared between patients with small versus large LVAs.</p><p><strong>Results: </strong>35 patients were included (87% male, median age 62). The median surface area of LVAs was 7.7 (4.4-15.8) cm<sup>2</sup> corresponding to 5.6 (3.3-12.1) % of LA endocardial surface. B2B index was 0.57 (0.52-0.59) in patients with small LVAs (below the median) compared to 0.65 (0.56-0.77) in those with large LVAs (above the median) (p = 0.009). In the receiver operator characteristic curve analysis for predicting large LVAs, the c-statistic was 0.75 (p = 0.006) for B2B index and 0.81 for the multivariable model including B2B index (multivariable p = 0.04) and P-wave duration.</p><p><strong>Conclusion: </strong>In patients with paroxysmal AF without overt atrial myopathy, B2B P-wave analysis appears to be a useful non-invasive correlate of low-voltage areas-and thus fibrosis-in the LA. This finding establishes a pathophysiological basis for B2B index and its potential usefulness in the selection process of patients who are likely to benefit most from further invasive treatment.</p>","PeriodicalId":55062,"journal":{"name":"Hellenic Journal of Cardiology","volume":" ","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2024-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hellenic Journal of Cardiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.hjc.2024.05.011","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Left atrial (LA) fibrosis has been shown to be associated with atrial fibrillation (AF) recurrence. Beat-to-beat (B2B) index is a non-invasive classifier, based on B2B P-wave morphological and wavelet analysis, shown to be associated with AF incidence and recurrence. In this study, we tested the hypothesis that the B2B index is associated with the extent of LA low-voltage areas (LVAs) on electroanatomical mapping.
Methods: Patients with paroxysmal AF scheduled for pulmonary vein isolation, without evident structural remodeling, were included. Pre-ablation electroanatomical voltage maps were used to calculate the surface of LVAs (<0.5 mV). B2B index was compared between patients with small versus large LVAs.
Results: 35 patients were included (87% male, median age 62). The median surface area of LVAs was 7.7 (4.4-15.8) cm2 corresponding to 5.6 (3.3-12.1) % of LA endocardial surface. B2B index was 0.57 (0.52-0.59) in patients with small LVAs (below the median) compared to 0.65 (0.56-0.77) in those with large LVAs (above the median) (p = 0.009). In the receiver operator characteristic curve analysis for predicting large LVAs, the c-statistic was 0.75 (p = 0.006) for B2B index and 0.81 for the multivariable model including B2B index (multivariable p = 0.04) and P-wave duration.
Conclusion: In patients with paroxysmal AF without overt atrial myopathy, B2B P-wave analysis appears to be a useful non-invasive correlate of low-voltage areas-and thus fibrosis-in the LA. This finding establishes a pathophysiological basis for B2B index and its potential usefulness in the selection process of patients who are likely to benefit most from further invasive treatment.
期刊介绍:
The Hellenic Journal of Cardiology (International Edition, ISSN 1109-9666) is the official journal of the Hellenic Society of Cardiology and aims to publish high-quality articles on all aspects of cardiovascular medicine. A primary goal is to publish in each issue a number of original articles related to clinical and basic research. Many of these will be accompanied by invited editorial comments.
Hot topics, such as molecular cardiology, and innovative cardiac imaging and electrophysiological mapping techniques, will appear frequently in the journal in the form of invited expert articles or special reports. The Editorial Committee also attaches great importance to subjects related to continuing medical education, the implementation of guidelines and cost effectiveness in cardiology.