Arterial oxygen pressure during veno-venous extracorporeal membrane oxygenation may be increased by advancing the tip of the drainage cannula into the superior vena cava: a case report.
{"title":"Arterial oxygen pressure during veno-venous extracorporeal membrane oxygenation may be increased by advancing the tip of the drainage cannula into the superior vena cava: a case report.","authors":"Tomoyuki Nakamura, Naohide Kuriyama, Yoshitaka Hara, Hidefumi Komura, Naoki Hoshino, Soshi Miyamoto, Ken Sawada, Takahiro Kawaji, Satoshi Komatsu, Osamu Nishida","doi":"10.1007/s10047-024-01448-w","DOIUrl":null,"url":null,"abstract":"<p><p>A simple and robust method for veno-venous extracorporeal membrane oxygenation (V-V ECMO) involves a drainage cannula into the inferior vena cava via the femoral vein (FV) and a reinfusion cannula into the right atrium (RA) via the internal jugular vein (IJV) (F-J configuration). However, with this method, the arterial oxygen (PaO<sub>2</sub>) is said to remain below 100 mmHg.Since recently, in our ICU, to prevent drainage failure, we apply a modification from the commonly practiced F-J configuration by advancing the tip of the drainage cannula inserted via the FV into the superior vena cava (SVC) and crossing the reinfusion cannula inserted via the IJV in the RA (F(SVC)-J(RA) configuration). We experienced that this modification can be associated with unexpectedly high PaO<sub>2</sub> values, which here we investigated in detail.Veno-arteriovenous ECMO was induced in a 65-year-old male patient who suffered from repeated cardiac arrest due to acute respiratory distress syndrome. His chest X-ray images showed white-out after lung rest setting, consistent with near-absence of self-lung ventilation. Cardiac function recovered and the system was converted to F(SVC)-J(RA) configuration, after which both PaO<sub>2</sub> and partial pressure of pulmonary arterial oxygen values remained high above 200 mmHg. Transesophageal echocardiography could not detect right-to-left shunt, and more efficient drainage of the native venous return flow compared to common F-J configuration may explain the increased PaO<sub>2</sub>.Although the F(SVC)-J(RA) configuration is a small modification of the F-J configuration, it seems to provide a revolutionary improvement in the ECMO field by combining robustness/simplicity with high PaO<sub>2</sub> values.</p>","PeriodicalId":15177,"journal":{"name":"Journal of Artificial Organs","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2024-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10047-024-01448-w","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
A simple and robust method for veno-venous extracorporeal membrane oxygenation (V-V ECMO) involves a drainage cannula into the inferior vena cava via the femoral vein (FV) and a reinfusion cannula into the right atrium (RA) via the internal jugular vein (IJV) (F-J configuration). However, with this method, the arterial oxygen (PaO2) is said to remain below 100 mmHg.Since recently, in our ICU, to prevent drainage failure, we apply a modification from the commonly practiced F-J configuration by advancing the tip of the drainage cannula inserted via the FV into the superior vena cava (SVC) and crossing the reinfusion cannula inserted via the IJV in the RA (F(SVC)-J(RA) configuration). We experienced that this modification can be associated with unexpectedly high PaO2 values, which here we investigated in detail.Veno-arteriovenous ECMO was induced in a 65-year-old male patient who suffered from repeated cardiac arrest due to acute respiratory distress syndrome. His chest X-ray images showed white-out after lung rest setting, consistent with near-absence of self-lung ventilation. Cardiac function recovered and the system was converted to F(SVC)-J(RA) configuration, after which both PaO2 and partial pressure of pulmonary arterial oxygen values remained high above 200 mmHg. Transesophageal echocardiography could not detect right-to-left shunt, and more efficient drainage of the native venous return flow compared to common F-J configuration may explain the increased PaO2.Although the F(SVC)-J(RA) configuration is a small modification of the F-J configuration, it seems to provide a revolutionary improvement in the ECMO field by combining robustness/simplicity with high PaO2 values.
期刊介绍:
The aim of the Journal of Artificial Organs is to introduce to colleagues worldwide a broad spectrum of important new achievements in the field of artificial organs, ranging from fundamental research to clinical applications. The scope of the Journal of Artificial Organs encompasses but is not restricted to blood purification, cardiovascular intervention, biomaterials, and artificial metabolic organs. Additionally, the journal will cover technical and industrial innovations. Membership in the Japanese Society for Artificial Organs is not a prerequisite for submission.