Use of High-density Mapping to Ablate a Wide Accessory Pathway and Mahaim Fiber in a Patient with Ebstein's Anomaly.

Q3 Medicine
Journal of Innovations in Cardiac Rhythm Management Pub Date : 2024-04-15 eCollection Date: 2024-04-01 DOI:10.19102/icrm.2024.15041
Eric Rosenthal, Timothey Un, Julian Bostock
{"title":"Use of High-density Mapping to Ablate a Wide Accessory Pathway and Mahaim Fiber in a Patient with Ebstein's Anomaly.","authors":"Eric Rosenthal, Timothey Un, Julian Bostock","doi":"10.19102/icrm.2024.15041","DOIUrl":null,"url":null,"abstract":"<p><p>Ablation of accessory pathways in patients with Ebstein's anomaly can be challenging. Despite increasing experience and advances in mapping technology, success is limited and recurrence rates can be high. To date, high-density electroanatomic mapping has not been studied in this anatomical substrate. We present a pediatric case of Ebstein's anomaly in which high-density mapping in Ebstein's anomaly was a useful additional tool to improve the outcome of catheter ablation.</p>","PeriodicalId":36299,"journal":{"name":"Journal of Innovations in Cardiac Rhythm Management","volume":"15 4","pages":"5823-5827"},"PeriodicalIF":0.0000,"publicationDate":"2024-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11073423/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Innovations in Cardiac Rhythm Management","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.19102/icrm.2024.15041","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Ablation of accessory pathways in patients with Ebstein's anomaly can be challenging. Despite increasing experience and advances in mapping technology, success is limited and recurrence rates can be high. To date, high-density electroanatomic mapping has not been studied in this anatomical substrate. We present a pediatric case of Ebstein's anomaly in which high-density mapping in Ebstein's anomaly was a useful additional tool to improve the outcome of catheter ablation.

使用高密度图谱消融一名埃布斯坦氏异常患者的宽辅助通路和马哈伊姆纤维。
对艾布斯坦氏畸形患者的附属通路进行消融具有挑战性。尽管经验不断增加,制图技术也在不断进步,但成功率仍然有限,复发率也很高。迄今为止,还没有针对这种解剖基质进行过高密度电解剖图绘制的研究。我们介绍了一例埃布斯坦氏畸形儿科病例,在该病例中,埃布斯坦氏畸形的高密度映射是改善导管消融结果的又一有用工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Innovations in Cardiac Rhythm Management
Journal of Innovations in Cardiac Rhythm Management Medicine-Cardiology and Cardiovascular Medicine
CiteScore
1.50
自引率
0.00%
发文量
70
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信