Shawn M. Hines , Michael J. Anderson , Brittany E. Homcha , Randy M. Hauck
{"title":"Surface wear of PyroCarbon implant in metacarpophalangeal joint arthroplasty without radiographic abnormality: A case report","authors":"Shawn M. Hines , Michael J. Anderson , Brittany E. Homcha , Randy M. Hauck","doi":"10.1016/j.hansur.2024.101689","DOIUrl":null,"url":null,"abstract":"<div><h3>Case</h3><p>A 54-year-old male with osteoarthritis of the right long finger metacarpophalangeal joint underwent PyroCarbon joint arthroplasty. Seven years later the patient presented for metacarpophalangeal joint swelling and pain. The workup was benign, without signs of implant complication or osseous abnormality. He underwent washout and two-stage revision, where gross implant wear and debris not demonstrated by radiograph were found. He then returned to the operating room for reimplantation of a PyroCarbon implant.</p></div><div><h3>Conclusion</h3><p>This case demonstrates a novel presentation of aseptic PyroCarbon implant failure in the hand without radiographic abnormality that can alter operative management by reducing operating room returns.</p></div>","PeriodicalId":54301,"journal":{"name":"Hand Surgery & Rehabilitation","volume":"43 3","pages":"Article 101689"},"PeriodicalIF":0.9000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hand Surgery & Rehabilitation","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2468122924000665","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Case
A 54-year-old male with osteoarthritis of the right long finger metacarpophalangeal joint underwent PyroCarbon joint arthroplasty. Seven years later the patient presented for metacarpophalangeal joint swelling and pain. The workup was benign, without signs of implant complication or osseous abnormality. He underwent washout and two-stage revision, where gross implant wear and debris not demonstrated by radiograph were found. He then returned to the operating room for reimplantation of a PyroCarbon implant.
Conclusion
This case demonstrates a novel presentation of aseptic PyroCarbon implant failure in the hand without radiographic abnormality that can alter operative management by reducing operating room returns.
期刊介绍:
As the official publication of the French, Belgian and Swiss Societies for Surgery of the Hand, as well as of the French Society of Rehabilitation of the Hand & Upper Limb, ''Hand Surgery and Rehabilitation'' - formerly named "Chirurgie de la Main" - publishes original articles, literature reviews, technical notes, and clinical cases. It is indexed in the main international databases (including Medline). Initially a platform for French-speaking hand surgeons, the journal will now publish its articles in English to disseminate its author''s scientific findings more widely. The journal also includes a biannual supplement in French, the monograph of the French Society for Surgery of the Hand, where comprehensive reviews in the fields of hand, peripheral nerve and upper limb surgery are presented.
Organe officiel de la Société française de chirurgie de la main, de la Société française de Rééducation de la main (SFRM-GEMMSOR), de la Société suisse de chirurgie de la main et du Belgian Hand Group, indexée dans les grandes bases de données internationales (Medline, Embase, Pascal, Scopus), Hand Surgery and Rehabilitation - anciennement titrée Chirurgie de la main - publie des articles originaux, des revues de la littérature, des notes techniques, des cas clinique. Initialement plateforme d''expression francophone de la spécialité, la revue s''oriente désormais vers l''anglais pour devenir une référence scientifique et de formation de la spécialité en France et en Europe. Avec 6 publications en anglais par an, la revue comprend également un supplément biannuel, la monographie du GEM, où sont présentées en français, des mises au point complètes dans les domaines de la chirurgie de la main, des nerfs périphériques et du membre supérieur.