{"title":"Minimally Invasive Treatment of Pelvic Fractures with Titanium Elastic Nailing: An Innovative Technology.","authors":"Zhaofeng Jia, Hanjun Qin, Jiandong Lin, Xin Wang, Ruochen Bai, Suying Zou, Wenjun Huang, Xinjia Hu","doi":"10.1177/15533506241249260","DOIUrl":null,"url":null,"abstract":"BACKGROUND\nMinimally invasive treatment has become the most popular and effective treatment for pelvic fractures. This study aimed to evaluate the safety and efficacy of a new technique, titanium elastic nailing (TEN), for the minimally invasive treatment of pelvic fractures.\n\n\nMETHOD\nTwenty-four patients with pelvic fractures were referred to us between January 2020 to January 2022, including sixteen males and 8 females. Pelvic fractures were temporarily fixed by pelvic fixation belt accompanied by traction from the lower limb bone. Anterior pelvic ring injuries (superior ramus of pubis) and ilium fractures were treated with closed reduction and intramedullary fixation with minimally invasive TEN. Intraoperative C-arm, including pelvic anteroposterior, pelvic outlet, inlet and ilium oblique views, and O-arm fluoroscopy (intraoperative CT) were employed to assess fractures reduction and determine the location of the elastic titanium nail within the bone channel.\n\n\nRESULTS\nBy adopting closed reduction and minimally invasive incision techniques, pelvic fractures could be safely fixed by placing an elastic titanium nail in the osseous medullary cavity channels of the pelvis. Postoperative investigation indicated that the wounds of all patients were healed in the first stage without any occurrence of complications, such as injuries to the nerves, blood vessels, and important tissue structures. Patients are essential quickly after the operation and could perform the functional exercise in the early stages of the recovery.\n\n\nCONCLUSION\nTEN can be used for minimally invasive treatment of pelvic fractures. This novel technique has no obvious complications and is worthwhile in clinical practice.","PeriodicalId":22095,"journal":{"name":"Surgical Innovation","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Innovation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15533506241249260","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
Abstract
BACKGROUND
Minimally invasive treatment has become the most popular and effective treatment for pelvic fractures. This study aimed to evaluate the safety and efficacy of a new technique, titanium elastic nailing (TEN), for the minimally invasive treatment of pelvic fractures.
METHOD
Twenty-four patients with pelvic fractures were referred to us between January 2020 to January 2022, including sixteen males and 8 females. Pelvic fractures were temporarily fixed by pelvic fixation belt accompanied by traction from the lower limb bone. Anterior pelvic ring injuries (superior ramus of pubis) and ilium fractures were treated with closed reduction and intramedullary fixation with minimally invasive TEN. Intraoperative C-arm, including pelvic anteroposterior, pelvic outlet, inlet and ilium oblique views, and O-arm fluoroscopy (intraoperative CT) were employed to assess fractures reduction and determine the location of the elastic titanium nail within the bone channel.
RESULTS
By adopting closed reduction and minimally invasive incision techniques, pelvic fractures could be safely fixed by placing an elastic titanium nail in the osseous medullary cavity channels of the pelvis. Postoperative investigation indicated that the wounds of all patients were healed in the first stage without any occurrence of complications, such as injuries to the nerves, blood vessels, and important tissue structures. Patients are essential quickly after the operation and could perform the functional exercise in the early stages of the recovery.
CONCLUSION
TEN can be used for minimally invasive treatment of pelvic fractures. This novel technique has no obvious complications and is worthwhile in clinical practice.
期刊介绍:
Surgical Innovation (SRI) is a peer-reviewed bi-monthly journal focusing on minimally invasive surgical techniques, new instruments such as laparoscopes and endoscopes, and new technologies. SRI prepares surgeons to think and work in "the operating room of the future" through learning new techniques, understanding and adapting to new technologies, maintaining surgical competencies, and applying surgical outcomes data to their practices. This journal is a member of the Committee on Publication Ethics (COPE).