{"title":"Delta-S-Cys-Albumin as a Marker of Pediatric Biospecimen Integrity.","authors":"Schuyler Kremer, Valentina Shakhnovich, Amanda K Riffel, Lisa Harvey, Chad R Borges","doi":"10.1089/bio.2023.0121","DOIUrl":null,"url":null,"abstract":"Blood plasma storage is a crucial element of pediatric biobanking. Improperly stored or handled specimens (e.g., at > -30°C) can result in altered biomolecular compositions that no longer reflects in vivo reality. We report application of a previously developed assay in adults-the ΔS-Cys-Albumin assay, which facilitates estimation of plasma and serum exposure to thawed conditions-to a population of pediatric EDTA plasma samples from patients aged 3-18 years to determine the assay's applicability, estimate its reference range for pediatric samples, and assess the impact of pre-centrifugation delay at 0°C. In addition, the effect of plasma thawed-state exposure to a range of times at 23°C, 4°C, and -20°C on ΔS-Cys-Albumin was evaluated. Using 98 precollected and processed pediatric EDTA plasma specimens, no difference was found in ΔS-Cys-Albumin under conditions of pre-centrifugation delay for up to 10 hours at 0°C. This lack of change allowed us to estimate a pediatric reference range for ΔS-Cys-Albumin of 7.0%-22.5% (mean of 12.8%) with a modest Pearson correlation between ΔS-Cys-Albumin and age (p = 0.0037, R2 = 0.29). ΔS-Cys-Albumin stability in six specimens at 23°C, 4°C, and -20°C was also evaluated. Plateaus in the decay curves were reached by 1 day, 7 days, and 14-28 days at these respective temperatures. The estimated pediatric reference range observed in children was lower than that previously observed in 180 adults of 12.3%-30.6% (mean of 20.0%), and the slope of the age correlation in children was twice as steep as that from adults. ΔS-Cys-Albumin decay curves at 23°C, 4°C, and -20°C were similar to those previously observed in adults. The data reported here support the use of ΔS-Cys-Albumin in evaluating the integrity and overall exposure of pediatric EDTA plasma specimens to thawed conditions. In doing so, they add an important quality control tool to the biobanker's arsenal.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1089/bio.2023.0121","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Blood plasma storage is a crucial element of pediatric biobanking. Improperly stored or handled specimens (e.g., at > -30°C) can result in altered biomolecular compositions that no longer reflects in vivo reality. We report application of a previously developed assay in adults-the ΔS-Cys-Albumin assay, which facilitates estimation of plasma and serum exposure to thawed conditions-to a population of pediatric EDTA plasma samples from patients aged 3-18 years to determine the assay's applicability, estimate its reference range for pediatric samples, and assess the impact of pre-centrifugation delay at 0°C. In addition, the effect of plasma thawed-state exposure to a range of times at 23°C, 4°C, and -20°C on ΔS-Cys-Albumin was evaluated. Using 98 precollected and processed pediatric EDTA plasma specimens, no difference was found in ΔS-Cys-Albumin under conditions of pre-centrifugation delay for up to 10 hours at 0°C. This lack of change allowed us to estimate a pediatric reference range for ΔS-Cys-Albumin of 7.0%-22.5% (mean of 12.8%) with a modest Pearson correlation between ΔS-Cys-Albumin and age (p = 0.0037, R2 = 0.29). ΔS-Cys-Albumin stability in six specimens at 23°C, 4°C, and -20°C was also evaluated. Plateaus in the decay curves were reached by 1 day, 7 days, and 14-28 days at these respective temperatures. The estimated pediatric reference range observed in children was lower than that previously observed in 180 adults of 12.3%-30.6% (mean of 20.0%), and the slope of the age correlation in children was twice as steep as that from adults. ΔS-Cys-Albumin decay curves at 23°C, 4°C, and -20°C were similar to those previously observed in adults. The data reported here support the use of ΔS-Cys-Albumin in evaluating the integrity and overall exposure of pediatric EDTA plasma specimens to thawed conditions. In doing so, they add an important quality control tool to the biobanker's arsenal.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.