Double novel integrated outside biliary stent and nasobiliary drainage catheter system placement for hilar biliary stricture

IF 5 2区 医学 Q1 GASTROENTEROLOGY & HEPATOLOGY
Akihiro Sekine, Kazunari Nakahara, Keisuke Tateishi
{"title":"Double novel integrated outside biliary stent and nasobiliary drainage catheter system placement for hilar biliary stricture","authors":"Akihiro Sekine,&nbsp;Kazunari Nakahara,&nbsp;Keisuke Tateishi","doi":"10.1111/den.14799","DOIUrl":null,"url":null,"abstract":"<p>A novel integrated biliary stent and nasobiliary drainage catheter system (UMIDAS NB stent [UMIDAS]; Olympus Medical Systems, Tokyo, Japan) was recently renewed.<span><sup>1, 2</sup></span> The renewed UMIDAS consists of a 7F or 8.5F outside biliary stent with a large flap on the distal side to prevent migration and a 5F nasobiliary catheter (Fig. 1). The advantage of the UMIDAS is that additional endoscopic retrograde cholangiopancreatography is not required because internal drainage can be achieved by simply removing the nasobiliary catheter.<span><sup>3, 4</sup></span> However, because of the large 8.5F diameter of the stent pushing sheath, it is impossible to deploy two UMIDASs through the scope channel. Here, we present a technique demonstrating the placement of two UMIDASs (Video S1).</p><p>External drainage of the right anterior and posterior bile ducts was planned before left hepatic lobectomy for hilar biliary stricture resulting from cholangiocarcinoma. Endoscopic retrograde cholangiopancreatography was performed using a duodenoscope (TJF-Q290V; Olympus Medical Systems). After bile duct cannulation, 0.025 inch guidewires were inserted into the anterior and posterior branches, followed by endoscopic sphincterotomy. Next, a UMIDAS with a 7F biliary stent was inserted into the anterior branch across the papilla. Because a second UMIDAS could not be inserted through the 4.2 mm diameter scope channel, pushing sheath and nasocatheter of the first UMIDAS were temporarily removed while retaining the biliary stent and guidewire in place (Fig. 2a). This allowed the second UMIDAS to be inserted through the channel and placed in the posterior branch (Fig. 2b). After removing the pushing sheath of the second UMIDAS, the nasocatheter of the first UMIDAS was reinserted through the lumen of the biliary stent and placed in the anterior branch (Fig. 2c,d).</p><p>A week later, the nasobiliary catheters were successfully extracted under fluoroscopic guidance while the biliary stents were retained in place.</p><p>Authors declare no conflict of interest for this article.</p>","PeriodicalId":159,"journal":{"name":"Digestive Endoscopy","volume":null,"pages":null},"PeriodicalIF":5.0000,"publicationDate":"2024-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/den.14799","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digestive Endoscopy","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/den.14799","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

A novel integrated biliary stent and nasobiliary drainage catheter system (UMIDAS NB stent [UMIDAS]; Olympus Medical Systems, Tokyo, Japan) was recently renewed.1, 2 The renewed UMIDAS consists of a 7F or 8.5F outside biliary stent with a large flap on the distal side to prevent migration and a 5F nasobiliary catheter (Fig. 1). The advantage of the UMIDAS is that additional endoscopic retrograde cholangiopancreatography is not required because internal drainage can be achieved by simply removing the nasobiliary catheter.3, 4 However, because of the large 8.5F diameter of the stent pushing sheath, it is impossible to deploy two UMIDASs through the scope channel. Here, we present a technique demonstrating the placement of two UMIDASs (Video S1).

External drainage of the right anterior and posterior bile ducts was planned before left hepatic lobectomy for hilar biliary stricture resulting from cholangiocarcinoma. Endoscopic retrograde cholangiopancreatography was performed using a duodenoscope (TJF-Q290V; Olympus Medical Systems). After bile duct cannulation, 0.025 inch guidewires were inserted into the anterior and posterior branches, followed by endoscopic sphincterotomy. Next, a UMIDAS with a 7F biliary stent was inserted into the anterior branch across the papilla. Because a second UMIDAS could not be inserted through the 4.2 mm diameter scope channel, pushing sheath and nasocatheter of the first UMIDAS were temporarily removed while retaining the biliary stent and guidewire in place (Fig. 2a). This allowed the second UMIDAS to be inserted through the channel and placed in the posterior branch (Fig. 2b). After removing the pushing sheath of the second UMIDAS, the nasocatheter of the first UMIDAS was reinserted through the lumen of the biliary stent and placed in the anterior branch (Fig. 2c,d).

A week later, the nasobiliary catheters were successfully extracted under fluoroscopic guidance while the biliary stents were retained in place.

Authors declare no conflict of interest for this article.

Abstract Image

胆道支架和鼻胆管引流导管系统的双重新型集成外置式胆道支架,用于治疗肝门胆道狭窄
观看本文视频。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Digestive Endoscopy
Digestive Endoscopy 医学-外科
CiteScore
10.10
自引率
15.10%
发文量
291
审稿时长
6-12 weeks
期刊介绍: Digestive Endoscopy (DEN) is the official journal of the Japan Gastroenterological Endoscopy Society, the Asian Pacific Society for Digestive Endoscopy and the World Endoscopy Organization. Digestive Endoscopy serves as a medium for presenting original articles that offer significant contributions to knowledge in the broad field of endoscopy. The Journal also includes Reviews, Original Articles, How I Do It, Case Reports (only of exceptional interest and novelty are accepted), Letters, Techniques and Images, abstracts and news items that may be of interest to endoscopists.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信