The diagnostic efficiency of artificial intelligence based 2 hours Holter monitoring in premature ventricular and supraventricular contractions detection

IF 2.4 3区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Qiong Huang MS, Yuansheng Fan MS, Jialin Wang BS, Zhiyang Xu MS, Linfeng Yang BS, Junhong Wang MD, PhD, Yiyang Zhan MD, PhD, Xiangqing Kong MD, PhD, Ningtian Zhou MD, PhD
{"title":"The diagnostic efficiency of artificial intelligence based 2 hours Holter monitoring in premature ventricular and supraventricular contractions detection","authors":"Qiong Huang MS,&nbsp;Yuansheng Fan MS,&nbsp;Jialin Wang BS,&nbsp;Zhiyang Xu MS,&nbsp;Linfeng Yang BS,&nbsp;Junhong Wang MD, PhD,&nbsp;Yiyang Zhan MD, PhD,&nbsp;Xiangqing Kong MD, PhD,&nbsp;Ningtian Zhou MD, PhD","doi":"10.1002/clc.24266","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Electrocardiography (ECG) and 24 hours Holter monitoring (24 h-Holter) provided valuable information for premature ventricular and supraventricular contractions (PVC and PSVC). Currently, artificial intelligence (AI) based 2 hours single-lead Holter (2 h-Holter) monitoring may provide an improved strategy for PSVC/PVC diagnosis.</p>\n </section>\n \n <section>\n \n <h3> Hypothesis</h3>\n \n <p>AI combined with single-lead Holter monitoring improves PSVC/PVC detection.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>In total, 170 patients were enrolled between August 2022 and 2023. All patients wore both devices simultaneously; then, we compared diagnostic efficiency, including the sensitivity/specificity/positive predictive-value (PPV) and negative predictive-value (NPV) in detecting PSVC/PVC by 24 h-Holter and 2 h-Holter.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The PPV and NPV in patients underwent 2 h-Holter were 76.00%/87.50% and 96.35%/98.55, respectively, and the sensitivity and specificity were 79.17%/91.30%, and 95.65%/97.84% in PSVC/PVC detection compared with 24 h-Holter. The areas under the ROC curves (AUCs) for PSVC and PVC were 0.885 and 0.741, respectively (<i>p</i> &lt; .0001).</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The potential advantages of the 2 h-Holter were shortened wearing period, improved convenience, and excellent consistency of diagnosis.</p>\n </section>\n </div>","PeriodicalId":10201,"journal":{"name":"Clinical Cardiology","volume":null,"pages":null},"PeriodicalIF":2.4000,"publicationDate":"2024-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/clc.24266","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Cardiology","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/clc.24266","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Electrocardiography (ECG) and 24 hours Holter monitoring (24 h-Holter) provided valuable information for premature ventricular and supraventricular contractions (PVC and PSVC). Currently, artificial intelligence (AI) based 2 hours single-lead Holter (2 h-Holter) monitoring may provide an improved strategy for PSVC/PVC diagnosis.

Hypothesis

AI combined with single-lead Holter monitoring improves PSVC/PVC detection.

Methods

In total, 170 patients were enrolled between August 2022 and 2023. All patients wore both devices simultaneously; then, we compared diagnostic efficiency, including the sensitivity/specificity/positive predictive-value (PPV) and negative predictive-value (NPV) in detecting PSVC/PVC by 24 h-Holter and 2 h-Holter.

Results

The PPV and NPV in patients underwent 2 h-Holter were 76.00%/87.50% and 96.35%/98.55, respectively, and the sensitivity and specificity were 79.17%/91.30%, and 95.65%/97.84% in PSVC/PVC detection compared with 24 h-Holter. The areas under the ROC curves (AUCs) for PSVC and PVC were 0.885 and 0.741, respectively (p < .0001).

Conclusions

The potential advantages of the 2 h-Holter were shortened wearing period, improved convenience, and excellent consistency of diagnosis.

Abstract Image

基于人工智能的 2 小时 Holter 监测在室性早搏和室上性收缩检测中的诊断效率
背景心电图(ECG)和 24 小时 Holter 监测(24 h-Holter)为室性早搏和室上性收缩(PVC 和 PSVC)提供了有价值的信息。目前,基于人工智能(AI)的 2 小时单导联 Holter(2 h-Holter)监测可为 PSVC/PVC 诊断提供更好的策略。 假设 人工智能与单导联 Holter 监测相结合可提高 PSVC/PVC 的检测率。 方法 在 2022 年 8 月至 2023 年期间,共招募了 170 名患者。所有患者同时佩戴两种设备,然后比较诊断效率,包括 24 h Holter 和 2 h Holter 检测 PSVC/PVC 的灵敏度/特异性/阳性预测值(PPV)和阴性预测值(NPV)。 结果 与24 h-Holter相比,接受2 h-Holter的患者的PPV和NPV分别为76.00%/87.50%和96.35%/98.55,PSVC/PVC检测的敏感性和特异性分别为79.17%/91.30%和95.65%/97.84%。PSVC 和 PVC 的 ROC 曲线下面积(AUC)分别为 0.885 和 0.741(p < .0001)。 结论 2 h-Holter 的潜在优势在于缩短了佩戴时间、提高了便利性和诊断的一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Clinical Cardiology
Clinical Cardiology 医学-心血管系统
CiteScore
5.10
自引率
3.70%
发文量
189
审稿时长
4-8 weeks
期刊介绍: Clinical Cardiology provides a fully Gold Open Access forum for the publication of original clinical research, as well as brief reviews of diagnostic and therapeutic issues in cardiovascular medicine and cardiovascular surgery. The journal includes Clinical Investigations, Reviews, free standing editorials and commentaries, and bonus online-only content. The journal also publishes supplements, Expert Panel Discussions, sponsored clinical Reviews, Trial Designs, and Quality and Outcomes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信