Effect of Simulated Gastric Juice on Color Stability of Different Artificial Teeth

IF 0.3 Q4 MEDICINE, RESEARCH & EXPERIMENTAL
Betül YILMAZ EVMEK, Elif Yeğin
{"title":"Effect of Simulated Gastric Juice on Color Stability of Different Artificial Teeth","authors":"Betül YILMAZ EVMEK, Elif Yeğin","doi":"10.33808/clinexphealthsci.1269843","DOIUrl":null,"url":null,"abstract":"Objective: The current study aimed to evaluate the gastric juice effect on the artificial teeth discoloration in patients with gastroesophageal reflux disease (GERD) under in vitro conditions. \nMethods: Three different artificial teeth (Ivostar, Vivodent PE, Phonares II) were used in the study (n=12). A spectrophotometer (VITA Easyshade Compact; VITA Zahnfabrik, Bad Säckingen, Germany) was used for initial color measurements after keeping the specimens in distilled water for 24 h. Then, they were immersed in 5% hydrochloric acid (HCl) at 37°C (pH=2) for 91 h and the color measurements were \nrepeated. The CIEDE2000 formulation was used to calculate the color changes. The statistical analysis was performed with one-way ANOVA and Tukey HSD tests. \nResults: Although the color differences of Vivodent PE and Phonares II materials did not exhibit a statistically significant difference (p=.95; p > .05), there was a significant difference between Ivostar and other materials (p=.02, p=.01). The 50:50% detection threshold (PT) was exceeded with Vivodent PE and Phonares II materials, while the 50:50% acceptability threshold (AT) was exceeded with Ivostar material. \nConclusion: After exposure to gastric acid, all groups exhibited perceptible color differences. In the group of acrylic resin artificial teeth, the color difference was above acceptability threshold and would be better to improve. While the acrylic resin artificial teeth exhibited the highest discoloration, artificial teeth containing nanohybrid composite resin showed the least discoloration. These should be considered in \nthe selection of artificial teeth in patients with GERD.","PeriodicalId":10192,"journal":{"name":"Clinical and Experimental Health Sciences","volume":null,"pages":null},"PeriodicalIF":0.3000,"publicationDate":"2024-01-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Experimental Health Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33808/clinexphealthsci.1269843","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The current study aimed to evaluate the gastric juice effect on the artificial teeth discoloration in patients with gastroesophageal reflux disease (GERD) under in vitro conditions. Methods: Three different artificial teeth (Ivostar, Vivodent PE, Phonares II) were used in the study (n=12). A spectrophotometer (VITA Easyshade Compact; VITA Zahnfabrik, Bad Säckingen, Germany) was used for initial color measurements after keeping the specimens in distilled water for 24 h. Then, they were immersed in 5% hydrochloric acid (HCl) at 37°C (pH=2) for 91 h and the color measurements were repeated. The CIEDE2000 formulation was used to calculate the color changes. The statistical analysis was performed with one-way ANOVA and Tukey HSD tests. Results: Although the color differences of Vivodent PE and Phonares II materials did not exhibit a statistically significant difference (p=.95; p > .05), there was a significant difference between Ivostar and other materials (p=.02, p=.01). The 50:50% detection threshold (PT) was exceeded with Vivodent PE and Phonares II materials, while the 50:50% acceptability threshold (AT) was exceeded with Ivostar material. Conclusion: After exposure to gastric acid, all groups exhibited perceptible color differences. In the group of acrylic resin artificial teeth, the color difference was above acceptability threshold and would be better to improve. While the acrylic resin artificial teeth exhibited the highest discoloration, artificial teeth containing nanohybrid composite resin showed the least discoloration. These should be considered in the selection of artificial teeth in patients with GERD.
模拟胃液对不同人造牙齿颜色稳定性的影响
研究目的本研究旨在体外条件下评估胃液对胃食管反流病患者人工牙齿变色的影响。研究方法研究中使用了三种不同的人造牙(Ivostar、Vivodent PE、Phonares II)(n=12)。使用分光光度计(VITA Easyshade Compact;VITA Zahnfabrik,Bad Säckingen,Germany)在蒸馏水中保存试样 24 小时后进行初始颜色测量,然后将试样浸入 5%的盐酸(HCl)中,温度为 37°C(pH=2),时间为 91 小时,然后重复测量颜色。使用 CIEDE2000 计算颜色变化。统计分析采用单因素方差分析和 Tukey HSD 检验。结果:虽然 Vivodent PE 和 Phonares II 材料的颜色差异没有统计学意义(p=.95;p > .05),但 Ivostar 和其他材料的颜色差异显著(p=.02,p=.01)。Vivodent PE 和 Phonares II 材料超过了 50:50% 的检测阈值 (PT),而 Ivostar 材料则超过了 50:50% 的可接受性阈值 (AT)。结论暴露于胃酸后,所有组别都表现出明显的色差。丙烯酸树脂人工牙组的色差超过了可接受性阈值,最好加以改进。丙烯酸树脂人工牙的变色程度最高,而含有纳米杂化复合树脂的人工牙的变色程度最低。胃食管反流患者在选择人工牙时应考虑这些因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Clinical and Experimental Health Sciences
Clinical and Experimental Health Sciences MEDICINE, RESEARCH & EXPERIMENTAL-
自引率
0.00%
发文量
73
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信