{"title":"Investigating the Effect of Direct Touch Method on Insulator Replacement in Candra Asri Feeder","authors":"I. Wayan, Dikse Pancane, Wayan Dikse","doi":"10.55927/fjsr.v3i2.7985","DOIUrl":null,"url":null,"abstract":"PLN UP3 East Bali in carrying out Fulcrum Insulator maintenance chooses to use Work In Direct Touch Voltage status. The purpose of using this method is to reduce the value of reliability indices in the form of System Averange Interruption Duration Index, System Averange Interruption Frequency Index, and Saving kWh which results in rupiah savings. The results showed that in 11 times the replacement work of the Fulcrum Insulator extinguishing method resulted in a SAIDI value of 0.105 minutes per customer, SAIFI of 0.104 times per customer. Meanwhile, if done with the Direct Touch method, PDKB gets a SAIDI and SAIFI value of 0. So if done with the Direct Touch Method, PDKB gets embedded 32,903.67 kWh and Rp. 42,248,314.85","PeriodicalId":492173,"journal":{"name":"Formosa Journal of Sustainable Research","volume":"28 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Formosa Journal of Sustainable Research","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.55927/fjsr.v3i2.7985","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

PLN UP3 East Bali in carrying out Fulcrum Insulator maintenance chooses to use Work In Direct Touch Voltage status. The purpose of using this method is to reduce the value of reliability indices in the form of System Averange Interruption Duration Index, System Averange Interruption Frequency Index, and Saving kWh which results in rupiah savings. The results showed that in 11 times the replacement work of the Fulcrum Insulator extinguishing method resulted in a SAIDI value of 0.105 minutes per customer, SAIFI of 0.104 times per customer. Meanwhile, if done with the Direct Touch method, PDKB gets a SAIDI and SAIFI value of 0. So if done with the Direct Touch Method, PDKB gets embedded 32,903.67 kWh and Rp. 42,248,314.85
调查直接接触法对 Candra Asri 给料机绝缘子更换的影响
PLN UP3 东巴厘岛分公司在进行支撑绝缘子维护时,选择使用直触电压状态下工作。使用这种方法的目的是降低系统平均中断持续时间指数、系统平均中断频率指数和节约千瓦时等可靠性指数值,从而节省印尼盾。结果表明,在 11 次更换工作中,支点绝缘子熄灭法的 SAIDI 值为每个用户 0.105 分钟,SAIFI 为每个用户 0.104 次。与此同时,如果采用直接接触法,PDKB 的 SAIDI 值和 SAIFI 值均为 0。因此,如果采用直接接触法,PDKB 可获得 32,903.67 千瓦时和 42,248,314.85 印尼盾。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信