Validity of resting heart rate derived from contact-based smartphone photoplethysmography compared with electrocardiography: a scoping review and checklist for optimal acquisition and reporting.

IF 3.2 Q1 HEALTH CARE SCIENCES & SERVICES
Frontiers in digital health Pub Date : 2024-02-29 eCollection Date: 2024-01-01 DOI:10.3389/fdgth.2024.1326511
James D Mather, Lawrence D Hayes, Jacqueline L Mair, Nicholas F Sculthorpe
{"title":"Validity of resting heart rate derived from contact-based smartphone photoplethysmography compared with electrocardiography: a scoping review and checklist for optimal acquisition and reporting.","authors":"James D Mather, Lawrence D Hayes, Jacqueline L Mair, Nicholas F Sculthorpe","doi":"10.3389/fdgth.2024.1326511","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>With the rise of smartphone ownership and increasing evidence to support the suitability of smartphone usage in healthcare, the light source and smartphone camera could be utilized to perform photoplethysmography (PPG) for the assessment of vital signs, such as heart rate (HR). However, until rigorous validity assessment has been conducted, PPG will have limited use in clinical settings.</p><p><strong>Objective: </strong>We aimed to conduct a scoping review assessing the validity of resting heart rate (RHR) acquisition from PPG utilizing contact-based smartphone devices. Our four specific objectives of this scoping review were to (1) conduct a systematic search of the published literature concerning contact-based smartphone device-derived PPG, (2) map study characteristics and methodologies, (3) identify if methodological and technological advancements have been made, and (4) provide recommendations for the advancement of the investigative area.</p><p><strong>Methods: </strong>ScienceDirect, PubMed and SPORTDiscus were searched for relevant studies between January 1st, 2007, and November 6th, 2022. Filters were applied to ensure only literature written in English were included. Reference lists of included studies were manually searched for additional eligible studies.</p><p><strong>Results: </strong>In total 10 articles were included. Articles varied in terms of methodology including study characteristics, index measurement characteristics, criterion measurement characteristics, and experimental procedure. Additionally, there were variations in reporting details including primary outcome measure and measure of validity. However, all studies reached the same conclusion, with agreement ranging between good to very strong and correlations ranging from <i>r </i>= .98 to 1.</p><p><strong>Conclusions: </strong>Smartphone applications measuring RHR derived from contact-based smartphone PPG appear to agree with gold standard electrocardiography (ECG) in healthy subjects. However, agreement was established under highly controlled conditions. Future research could investigate their validity and consider effective approaches that transfer these methods from laboratory conditions into the \"real-world\", in both healthy and clinical populations.</p>","PeriodicalId":73078,"journal":{"name":"Frontiers in digital health","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-02-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10937558/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in digital health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/fdgth.2024.1326511","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0

Abstract

Background: With the rise of smartphone ownership and increasing evidence to support the suitability of smartphone usage in healthcare, the light source and smartphone camera could be utilized to perform photoplethysmography (PPG) for the assessment of vital signs, such as heart rate (HR). However, until rigorous validity assessment has been conducted, PPG will have limited use in clinical settings.

Objective: We aimed to conduct a scoping review assessing the validity of resting heart rate (RHR) acquisition from PPG utilizing contact-based smartphone devices. Our four specific objectives of this scoping review were to (1) conduct a systematic search of the published literature concerning contact-based smartphone device-derived PPG, (2) map study characteristics and methodologies, (3) identify if methodological and technological advancements have been made, and (4) provide recommendations for the advancement of the investigative area.

Methods: ScienceDirect, PubMed and SPORTDiscus were searched for relevant studies between January 1st, 2007, and November 6th, 2022. Filters were applied to ensure only literature written in English were included. Reference lists of included studies were manually searched for additional eligible studies.

Results: In total 10 articles were included. Articles varied in terms of methodology including study characteristics, index measurement characteristics, criterion measurement characteristics, and experimental procedure. Additionally, there were variations in reporting details including primary outcome measure and measure of validity. However, all studies reached the same conclusion, with agreement ranging between good to very strong and correlations ranging from r = .98 to 1.

Conclusions: Smartphone applications measuring RHR derived from contact-based smartphone PPG appear to agree with gold standard electrocardiography (ECG) in healthy subjects. However, agreement was established under highly controlled conditions. Future research could investigate their validity and consider effective approaches that transfer these methods from laboratory conditions into the "real-world", in both healthy and clinical populations.

与心电图相比,接触式智能手机照相血压计得出的静息心率的有效性:范围综述及最佳采集和报告清单。
背景:随着智能手机保有量的增加以及越来越多的证据表明智能手机适用于医疗保健领域,光源和智能手机摄像头可用于进行光电血压计(PPG),以评估心率(HR)等生命体征。然而,在进行严格的有效性评估之前,PPG 在临床环境中的应用将十分有限:我们旨在对利用接触式智能手机设备从 PPG 获取静息心率 (RHR) 的有效性进行范围界定。我们此次范围界定综述的四个具体目标是:(1)对已发表的有关基于接触式智能手机设备的 PPG 的文献进行系统检索;(2)绘制研究特征和方法图;(3)确定方法和技术是否有所进步;以及(4)为推进该研究领域提供建议:方法:在 ScienceDirect、PubMed 和 SPORTDiscus 上搜索 2007 年 1 月 1 日至 2022 年 11 月 6 日期间的相关研究。为确保只收录英文文献,采用了过滤器。人工检索了纳入研究的参考文献目录,以寻找更多符合条件的研究:结果:共纳入 10 篇文章。文章的研究方法各不相同,包括研究特点、指标测量特点、标准测量特点和实验过程。此外,在报告细节(包括主要结果测量和有效性测量)方面也存在差异。不过,所有研究都得出了相同的结论,一致性从良好到非常强,相关性从 r = .98 到 1.结论:通过接触式智能手机 PPG 测量 RHR 的智能手机应用似乎与健康受试者的黄金标准心电图(ECG)一致。然而,这种一致性是在高度受控的条件下建立的。未来的研究可以调查其有效性,并考虑在健康和临床人群中将这些方法从实验室条件转移到 "真实世界 "的有效方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.20
自引率
0.00%
发文量
0
审稿时长
13 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信