Transcatheter closure of atrial septal defect using intracardiac echocardiography: a two-center, retrospective study.

IF 2.9 3区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Journal of Cardiovascular Medicine Pub Date : 2024-04-01 Epub Date: 2024-03-01 DOI:10.2459/JCM.0000000000001603
Katya Lucarelli, Tommaso Acquaviva, Paolo Ferrero, Emanuela De Cillis, Vito Casamassima, Eloisa Basile, Erasmo Cacciapaglia, Elia Iorio, Marcello Martimucci, Giacomo Cecere, Pierpaolo Petti, Rosa Caruso, Tommaso Langialonga, Alessandro Bortone, Massimo Grimaldi, Massimo Chessa
{"title":"Transcatheter closure of atrial septal defect using intracardiac echocardiography: a two-center, retrospective study.","authors":"Katya Lucarelli, Tommaso Acquaviva, Paolo Ferrero, Emanuela De Cillis, Vito Casamassima, Eloisa Basile, Erasmo Cacciapaglia, Elia Iorio, Marcello Martimucci, Giacomo Cecere, Pierpaolo Petti, Rosa Caruso, Tommaso Langialonga, Alessandro Bortone, Massimo Grimaldi, Massimo Chessa","doi":"10.2459/JCM.0000000000001603","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>We present the experience and long-term results of intracardiac echocardiography (ICE)-guided closure of ostium secundum atrial septal defects (ASDs) in two Italian centers and investigate its systematic applicability as the gold standard in routine clinical practice.</p><p><strong>Methods: </strong>We retrospectively evaluated all consecutive patients who underwent an ASD percutaneous closure procedure from March 2008 to February 2020. All patients underwent a preprocedural transesophageal echocardiography (TEE) evaluation. The closures were carried out under fluoroscopic and ICE guidance. A follow-up visit was performed at 1, 3 and 12 months, followed by telephone evaluations approximately every 2 years.</p><p><strong>Results: </strong>Sixty-six patients (29% male individuals), mean age 43 ± 16 years, were treated. In 15 cases, the TEE defect diameter was less than 10 mm, and in 8 of these patients, the ICE intraprocedural sizing increased the maximum diameter by more than 5 mm. Sizing balloon of the defect was performed in 51 cases; 2 patients received an ASD 38 mm device. Eight patients had multiple defects; in three of these, it was necessary to apply two devices. Four patients showed nonsignificant residual shunt; no complications related to the use of ICE were observed. One patient presented the migration of the ASD device into the abdominal aorta, percutaneously retrieved with a snare. No major complications were recorded during the entire follow-up period.</p><p><strong>Conclusion: </strong>This study confirms that ICE monitoring during ASD percutaneous closure is well tolerated and effective; it might be achievable as a routine gold standard by operators willing to use ICE systematically in all transcatheter closure interventions of interatrial communications.</p>","PeriodicalId":15228,"journal":{"name":"Journal of Cardiovascular Medicine","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2459/JCM.0000000000001603","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/1 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: We present the experience and long-term results of intracardiac echocardiography (ICE)-guided closure of ostium secundum atrial septal defects (ASDs) in two Italian centers and investigate its systematic applicability as the gold standard in routine clinical practice.

Methods: We retrospectively evaluated all consecutive patients who underwent an ASD percutaneous closure procedure from March 2008 to February 2020. All patients underwent a preprocedural transesophageal echocardiography (TEE) evaluation. The closures were carried out under fluoroscopic and ICE guidance. A follow-up visit was performed at 1, 3 and 12 months, followed by telephone evaluations approximately every 2 years.

Results: Sixty-six patients (29% male individuals), mean age 43 ± 16 years, were treated. In 15 cases, the TEE defect diameter was less than 10 mm, and in 8 of these patients, the ICE intraprocedural sizing increased the maximum diameter by more than 5 mm. Sizing balloon of the defect was performed in 51 cases; 2 patients received an ASD 38 mm device. Eight patients had multiple defects; in three of these, it was necessary to apply two devices. Four patients showed nonsignificant residual shunt; no complications related to the use of ICE were observed. One patient presented the migration of the ASD device into the abdominal aorta, percutaneously retrieved with a snare. No major complications were recorded during the entire follow-up period.

Conclusion: This study confirms that ICE monitoring during ASD percutaneous closure is well tolerated and effective; it might be achievable as a routine gold standard by operators willing to use ICE systematically in all transcatheter closure interventions of interatrial communications.

使用心内超声心动图经导管关闭房间隔缺损:一项双中心回顾性研究。
目的:我们介绍了意大利两个中心在心内超声心动图(ICE)引导下关闭房间隔缺损(ASD)的经验和长期结果,并研究了其作为常规临床实践金标准的系统适用性:我们对 2008 年 3 月至 2020 年 2 月期间接受 ASD 经皮闭合术的所有连续患者进行了回顾性评估。所有患者均接受了术前经食道超声心动图(TEE)评估。闭合手术在透视和 ICE 引导下进行。1个月、3个月和12个月进行一次随访,之后大约每两年进行一次电话评估:接受治疗的 66 名患者(29% 为男性),平均年龄为 43±16 岁。有 15 例患者的 TEE 缺口直径小于 10 毫米,其中有 8 例患者的 ICE 术中尺寸将最大直径增加了 5 毫米以上。在 51 例患者中,对缺损进行了球囊扩张;2 例患者接受了 ASD 38 毫米装置。8 名患者有多个缺损,其中 3 名患者需要使用两个装置。四名患者出现了不明显的残余分流;没有观察到与使用 ICE 有关的并发症。一名患者的 ASD 装置移入腹主动脉,经皮用卡环取出。整个随访期间未发现重大并发症:这项研究证实,ASD经皮闭合术中的ICE监测具有良好的耐受性和有效性;对于愿意在所有经导管闭合房室间通道介入术中系统性使用ICE的操作者来说,ICE监测可以作为常规的金标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Cardiovascular Medicine
Journal of Cardiovascular Medicine 医学-心血管系统
CiteScore
3.90
自引率
26.70%
发文量
189
审稿时长
6-12 weeks
期刊介绍: Journal of Cardiovascular Medicine is a monthly publication of the Italian Federation of Cardiology. It publishes original research articles, epidemiological studies, new methodological clinical approaches, case reports, design and goals of clinical trials, review articles, points of view, editorials and Images in cardiovascular medicine. Submitted articles undergo a preliminary review by the editor. Some articles may be returned to authors without further consideration. Those being considered for publication will undergo further assessment and peer-review by the editors and those invited to do so from a reviewer pool. ​
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信