Efficacy and safety of high-power short-duration ablation for atrial fibrillation: a systematic review and meta-analysis of randomized controlled trials.
Ahmed Mazen Amin, Ramy Ghaly, Ahmed A Ibrahim, Mohamed Ahmed Ali, Omar Almaadawy, Amr Elzahaby, Mohamed Abuelazm, Basel Abdelazeem, Muhammad Bilal Munir
{"title":"Efficacy and safety of high-power short-duration ablation for atrial fibrillation: a systematic review and meta-analysis of randomized controlled trials.","authors":"Ahmed Mazen Amin, Ramy Ghaly, Ahmed A Ibrahim, Mohamed Ahmed Ali, Omar Almaadawy, Amr Elzahaby, Mohamed Abuelazm, Basel Abdelazeem, Muhammad Bilal Munir","doi":"10.1007/s10840-024-01782-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>High-power short-duration (HPSD) ablation has emerged as an alternative to conventional standard-power long-duration (SPLD) ablation. We aim to assess the efficacy and safety of HPSD versus SPLD for atrial fibrillation (AF) ablation.</p><p><strong>Methods: </strong>A systematic review and meta-analysis of randomized controlled trials (RCTs) retrieved from PubMed, WOS, SCOPUS, EMBASE, and CENTRAL were performed through August 2023. We used RevMan V. 5.4 to pool dichotomous data using risk ratio (RR) and continuous data using mean difference (MD) with a 95% confidence interval (CI).</p><p><strong>Prospero id: </strong>CRD42023471797.</p><p><strong>Results: </strong>We included six RCTs with a total of 694 patients. HPSD was significantly associated with a decreased total procedure time (MD: -22.88 with 95% CI [-36.13, -9.63], P = 0.0007), pulmonary vein isolation (PVI) time (MD: -19.73 with 95% CI [-23.93, -15.53], P < 0.00001), radiofrequency time (MD: -10.53 with 95% CI [-12.87, -8.19], P < 0.00001). However, there was no significant difference between HPSD and SPLD ablation with respect to the fluoroscopy time (MD: -0.69 with 95% CI [-2.00, 0.62], P = 0.30), the incidence of esophageal lesions (RR: 1.15 with 95% CI [0.43, 3.07], P = 0.77), and the incidence of first pass isolation (RR: 0.98 with 95% CI [0.88, 1.08], P = 0.65).</p><p><strong>Conclusion: </strong>HPSD ablation was significantly associated with decreased total procedure time, PVI time, and radiofrequency time compared with SPLD ablation. On the contrary, SPLD ablation was significantly associated with low maximum temperature.</p>","PeriodicalId":16202,"journal":{"name":"Journal of Interventional Cardiac Electrophysiology","volume":" ","pages":"1445-1461"},"PeriodicalIF":2.1000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11379757/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Interventional Cardiac Electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10840-024-01782-2","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/9 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: High-power short-duration (HPSD) ablation has emerged as an alternative to conventional standard-power long-duration (SPLD) ablation. We aim to assess the efficacy and safety of HPSD versus SPLD for atrial fibrillation (AF) ablation.
Methods: A systematic review and meta-analysis of randomized controlled trials (RCTs) retrieved from PubMed, WOS, SCOPUS, EMBASE, and CENTRAL were performed through August 2023. We used RevMan V. 5.4 to pool dichotomous data using risk ratio (RR) and continuous data using mean difference (MD) with a 95% confidence interval (CI).
Prospero id: CRD42023471797.
Results: We included six RCTs with a total of 694 patients. HPSD was significantly associated with a decreased total procedure time (MD: -22.88 with 95% CI [-36.13, -9.63], P = 0.0007), pulmonary vein isolation (PVI) time (MD: -19.73 with 95% CI [-23.93, -15.53], P < 0.00001), radiofrequency time (MD: -10.53 with 95% CI [-12.87, -8.19], P < 0.00001). However, there was no significant difference between HPSD and SPLD ablation with respect to the fluoroscopy time (MD: -0.69 with 95% CI [-2.00, 0.62], P = 0.30), the incidence of esophageal lesions (RR: 1.15 with 95% CI [0.43, 3.07], P = 0.77), and the incidence of first pass isolation (RR: 0.98 with 95% CI [0.88, 1.08], P = 0.65).
Conclusion: HPSD ablation was significantly associated with decreased total procedure time, PVI time, and radiofrequency time compared with SPLD ablation. On the contrary, SPLD ablation was significantly associated with low maximum temperature.
期刊介绍:
The Journal of Interventional Cardiac Electrophysiology is an international publication devoted to fostering research in and development of interventional techniques and therapies for the management of cardiac arrhythmias. It is designed primarily to present original research studies and scholarly scientific reviews of basic and applied science and clinical research in this field. The Journal will adopt a multidisciplinary approach to link physical, experimental, and clinical sciences as applied to the development of and practice in interventional electrophysiology. The Journal will examine techniques ranging from molecular, chemical and pharmacologic therapies to device and ablation technology. Accordingly, original research in clinical, epidemiologic and basic science arenas will be considered for publication. Applied engineering or physical science studies pertaining to interventional electrophysiology will be encouraged. The Journal is committed to providing comprehensive and detailed treatment of major interventional therapies and innovative techniques in a structured and clinically relevant manner. It is directed at clinical practitioners and investigators in the rapidly growing field of interventional electrophysiology. The editorial staff and board reflect this bias and include noted international experts in this area with a wealth of expertise in basic and clinical investigation. Peer review of all submissions, conflict of interest guidelines and periodic editorial board review of all Journal policies have been established.