Quantifying carboxymethyl lysine and carboxyethyl lysine in human plasma: clinical insights into aging research using liquid chromatography-tandem mass spectrometry

IF 3.5 3区 生物学 Q2 BIOTECHNOLOGY & APPLIED MICROBIOLOGY
Daguang Wang, Junshan Wang, Xinghong Liu, Kehe Du, Hongjun Liu, Xiaofeng Yang, Tianyi Liu, Qian Liu, Meng Wang, Jian Guo
{"title":"Quantifying carboxymethyl lysine and carboxyethyl lysine in human plasma: clinical insights into aging research using liquid chromatography-tandem mass spectrometry","authors":"Daguang Wang, Junshan Wang, Xinghong Liu, Kehe Du, Hongjun Liu, Xiaofeng Yang, Tianyi Liu, Qian Liu, Meng Wang, Jian Guo","doi":"10.1186/s12896-024-00838-5","DOIUrl":null,"url":null,"abstract":"The objective of this study was to establish a methodology for determining carboxymethyl lysine (CML) and carboxyethyl lysine (CEL) concentrations in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The test results were also used for clinical aging research. Human plasma samples were incubated with aqueous perfluorovaleric acid (NFPA), succeeded by precipitation utilizing trichloroacetic acid, hydrolysis facilitated by hydrochloric acid, nitrogen drying, and ultimate re-dissolution utilizing NFPA, followed by filtration. Cotinine-D3 was added as an internal standard. The separation was performed on an Agela Venusil ASB C18 column (50 mm × 4.6 mm, 5 μm) with a 5 mmol/L NFPA and acetonitrile/water of 60:40 (v/v) containing 0.15% formic acid. The multiple reaction monitoring mode was used for detecting CML, CEL, and cotinine-D3, with ion pairs m/z 205.2 > 84.1 (for quantitative) and m/z 205.2 > m/z 130.0 for CML, m/z 219.1 > 84.1 (for quantitative) and m/z 219.1 > m/z 130.1 for CEL, and m/z 180.1 > 80.1 for cotinine-D3, respectively. The separation of CML and CEL was accomplished within a total analysis time of 6 minutes. The retention times of CML, CEL, and cotinine-D3 were 3.43 minutes, 3.46 minutes, and 4.50 minutes, respectively. The assay exhibited linearity in the concentration range of 0.025–1.500 μmol/L, with a lower limit of quantification of 0.025 μmol/L for both compounds. The relative standard deviations of intra-day and inter-day were both below 9%, and the relative errors were both within the range of ±4%. The average recoveries were 94.24% for CML and 97.89% for CEL. The results indicate that the developed methodology is fast, highly sensitive, highly specific, reproducible, and suitable for the rapid detection of CML and CEL in clinical human plasma samples. The outcomes of the clinical research project on aging underscored the important indicative significance of these two indicators for research on human aging.","PeriodicalId":8905,"journal":{"name":"BMC Biotechnology","volume":"5 1","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2024-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Biotechnology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1186/s12896-024-00838-5","RegionNum":3,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The objective of this study was to establish a methodology for determining carboxymethyl lysine (CML) and carboxyethyl lysine (CEL) concentrations in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The test results were also used for clinical aging research. Human plasma samples were incubated with aqueous perfluorovaleric acid (NFPA), succeeded by precipitation utilizing trichloroacetic acid, hydrolysis facilitated by hydrochloric acid, nitrogen drying, and ultimate re-dissolution utilizing NFPA, followed by filtration. Cotinine-D3 was added as an internal standard. The separation was performed on an Agela Venusil ASB C18 column (50 mm × 4.6 mm, 5 μm) with a 5 mmol/L NFPA and acetonitrile/water of 60:40 (v/v) containing 0.15% formic acid. The multiple reaction monitoring mode was used for detecting CML, CEL, and cotinine-D3, with ion pairs m/z 205.2 > 84.1 (for quantitative) and m/z 205.2 > m/z 130.0 for CML, m/z 219.1 > 84.1 (for quantitative) and m/z 219.1 > m/z 130.1 for CEL, and m/z 180.1 > 80.1 for cotinine-D3, respectively. The separation of CML and CEL was accomplished within a total analysis time of 6 minutes. The retention times of CML, CEL, and cotinine-D3 were 3.43 minutes, 3.46 minutes, and 4.50 minutes, respectively. The assay exhibited linearity in the concentration range of 0.025–1.500 μmol/L, with a lower limit of quantification of 0.025 μmol/L for both compounds. The relative standard deviations of intra-day and inter-day were both below 9%, and the relative errors were both within the range of ±4%. The average recoveries were 94.24% for CML and 97.89% for CEL. The results indicate that the developed methodology is fast, highly sensitive, highly specific, reproducible, and suitable for the rapid detection of CML and CEL in clinical human plasma samples. The outcomes of the clinical research project on aging underscored the important indicative significance of these two indicators for research on human aging.
人体血浆中羧甲基赖氨酸和羧乙基赖氨酸的定量分析:利用液相色谱-串联质谱法进行衰老研究的临床启示
本研究的目的是利用液相色谱-串联质谱法(LC-MS/MS)建立一种测定人体血浆中羧甲基赖氨酸(CML)和羧乙基赖氨酸(CEL)浓度的方法。检测结果还可用于临床老化研究。人体血浆样本先与全氟戊酸(NFPA)水溶液混合,然后用三氯乙酸沉淀,用盐酸水解,氮气干燥,最后用全氟戊酸再溶解,然后过滤。加入肉碱-D3 作为内标。采用 Agela Venusil ASB C18 色谱柱(50 mm × 4.6 mm,5 μm),5 mmol/L NFPA 和含 0.15%甲酸的乙腈/水(60:40 (v/v))进行分离。采用多反应监测模式检测 CML、CEL 和 cotinine-D3,CML 的离子对分别为 m/z 205.2 > 84.1(定量)和 m/z 205.2 > m/z 130.0,CEL 的离子对分别为 m/z 219.1 > 84.1(定量)和 m/z 219.1 > m/z 130.1,cotinine-D3 的离子对分别为 m/z 180.1 > 80.1。在总共 6 分钟的分析时间内完成了 CML 和 CEL 的分离。CML、CEL 和可替宁-D3 的保留时间分别为 3.43 分钟、3.46 分钟和 4.50 分钟。该测定在 0.025-1.500 μmol/L 浓度范围内呈线性关系,两种化合物的定量下限均为 0.025 μmol/L。日内和日间相对标准偏差均低于 9%,相对误差均在±4%范围内。CML 的平均回收率为 94.24%,CEL 的平均回收率为 97.89%。结果表明,所开发的方法快速、灵敏度高、特异性强、重现性好,适用于临床人体血浆样本中 CML 和 CEL 的快速检测。老龄化临床研究项目的成果凸显了这两项指标对人类老龄化研究的重要指示意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Biotechnology
BMC Biotechnology 工程技术-生物工程与应用微生物
CiteScore
6.60
自引率
0.00%
发文量
34
审稿时长
2 months
期刊介绍: BMC Biotechnology is an open access, peer-reviewed journal that considers articles on the manipulation of biological macromolecules or organisms for use in experimental procedures, cellular and tissue engineering or in the pharmaceutical, agricultural biotechnology and allied industries.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信