Comprehensive functional outcome analysis and importance of bone remodelling on personalized cranioplasty treatment using Poly(methyl methacrylate) bone flaps.
{"title":"Comprehensive functional outcome analysis and importance of bone remodelling on personalized cranioplasty treatment using Poly(methyl methacrylate) bone flaps.","authors":"Sandeep Iratwar, Sulob Roy Chowdhury, Shweta Pisulkar, Soumitra Das, Akhilesh Agarwal, Ashutosh Bagde, Balaji Paikrao, Syed Quazi, Bikramjit Basu","doi":"10.1177/08853282241235884","DOIUrl":null,"url":null,"abstract":"<p><p>Cranioplasty involves the surgical reconstruction of cranial defects arising as a result of various factors, including decompressive craniectomy, cranial malformations, and brain injury due to road traffic accidents. Most of the modern decompressive craniectomies (DC) warrant a future cranioplasty surgery within 6-36 months. The conventional process of capturing the defect impression and polymethyl methacrylate (PMMA) flap fabrication results in a misfit or misalignment at the site of implantation. Equally, the intra-operative graft preparation is arduous and can result in a longer surgical time, which may compromise the functional and aesthetic outcomes. As part of a multicentric pilot clinical study, we recently conducted a cohort study on ten human subjects during 2019-2022, following the human ethics committee approvals from the participating institutes. In the current study, an important aspect of measuring the extent of bone remodelling during the time gap between decompressive craniectomy and cranioplasty was successfully evaluated. The sterilised PMMA bone flaps were implanted at the defect area during the cranioplasty surgery using titanium mini plates and screws. The mean surgery time was 90 ± 20 min, comparable to the other clinical studies on cranioplasty. No signs of intra-operative and post-operative complications, such as cerebrospinal fluid leakage, hematoma, or local and systemic infection, were clinically recorded. Importantly, aesthetic outcomes were excellent for all the patients, except in a few clinical cases, wherein the PMMA bone flap was to be carefully customized due to the remodelling of the native skull bone. The extent of physiological remodelling was evaluated by superimposing the pre-operative and post-operative CT scan data after converting the defect morphology into a 3D model. This study further establishes the safety and efficacy of a technologically better approach to fabricate patient-specific acrylic bone flaps with improved surgical outcomes. More importantly, the study outcome further demonstrates the strategy to address bone remodelling during the patient-specific implant design.</p>","PeriodicalId":15138,"journal":{"name":"Journal of Biomaterials Applications","volume":" ","pages":"975-988"},"PeriodicalIF":2.3000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomaterials Applications","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/08853282241235884","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/29 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Cranioplasty involves the surgical reconstruction of cranial defects arising as a result of various factors, including decompressive craniectomy, cranial malformations, and brain injury due to road traffic accidents. Most of the modern decompressive craniectomies (DC) warrant a future cranioplasty surgery within 6-36 months. The conventional process of capturing the defect impression and polymethyl methacrylate (PMMA) flap fabrication results in a misfit or misalignment at the site of implantation. Equally, the intra-operative graft preparation is arduous and can result in a longer surgical time, which may compromise the functional and aesthetic outcomes. As part of a multicentric pilot clinical study, we recently conducted a cohort study on ten human subjects during 2019-2022, following the human ethics committee approvals from the participating institutes. In the current study, an important aspect of measuring the extent of bone remodelling during the time gap between decompressive craniectomy and cranioplasty was successfully evaluated. The sterilised PMMA bone flaps were implanted at the defect area during the cranioplasty surgery using titanium mini plates and screws. The mean surgery time was 90 ± 20 min, comparable to the other clinical studies on cranioplasty. No signs of intra-operative and post-operative complications, such as cerebrospinal fluid leakage, hematoma, or local and systemic infection, were clinically recorded. Importantly, aesthetic outcomes were excellent for all the patients, except in a few clinical cases, wherein the PMMA bone flap was to be carefully customized due to the remodelling of the native skull bone. The extent of physiological remodelling was evaluated by superimposing the pre-operative and post-operative CT scan data after converting the defect morphology into a 3D model. This study further establishes the safety and efficacy of a technologically better approach to fabricate patient-specific acrylic bone flaps with improved surgical outcomes. More importantly, the study outcome further demonstrates the strategy to address bone remodelling during the patient-specific implant design.
期刊介绍:
The Journal of Biomaterials Applications is a fully peer reviewed international journal that publishes original research and review articles that emphasize the development, manufacture and clinical applications of biomaterials.
Peer-reviewed articles by biomedical specialists from around the world cover:
New developments in biomaterials, R&D, properties and performance, evaluation and applications
Applications in biomedical materials and devices - from sutures and wound dressings to biosensors and cardiovascular devices
Current findings in biological compatibility/incompatibility of biomaterials
The Journal of Biomaterials Applications publishes original articles that emphasize the development, manufacture and clinical applications of biomaterials. Biomaterials continue to be one of the most rapidly growing areas of research in plastics today and certainly one of the biggest technical challenges, since biomaterial performance is dependent on polymer compatibility with the aggressive biological environment. The Journal cuts across disciplines and focuses on medical research and topics that present the broadest view of practical applications of biomaterials in actual clinical use.
The Journal of Biomaterial Applications is devoted to new and emerging biomaterials technologies, particularly focusing on the many applications which are under development at industrial biomedical and polymer research facilities, as well as the ongoing activities in academic, medical and applied clinical uses of devices.