{"title":"Reverse phase liquid chromatographic method for the measurement of uranium in process stream solutions from uranium extraction facility","authors":"Yarasi Balaji Rao, Shehanaz Bano, Putta V. Nagendra Kumar, Dinesh Srivastava","doi":"10.1515/ract-2023-0187","DOIUrl":null,"url":null,"abstract":"The present paper describes a simple method for the determination of uranium in uranium process stream solutions by reversed-phase liquid chromatographic method using C18 column, mixture of α-hydroxy isobutyric acid and methanol as eluent and flow-through spectrophotometer detector. This method has an advantage that interfering elements like rare-earth elements do not retain on the column and elute near the solvent peak thereby not interfering with uranium elution peak. Different eluents and parameters like pH, concentration of eluent are studied for the purpose. The spiking standard recovery was found to be more than 90 %. The developed method has been compared with other techniques and found to be in agreement.","PeriodicalId":21167,"journal":{"name":"Radiochimica Acta","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiochimica Acta","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1515/ract-2023-0187","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
引用次数: 0

Abstract

The present paper describes a simple method for the determination of uranium in uranium process stream solutions by reversed-phase liquid chromatographic method using C18 column, mixture of α-hydroxy isobutyric acid and methanol as eluent and flow-through spectrophotometer detector. This method has an advantage that interfering elements like rare-earth elements do not retain on the column and elute near the solvent peak thereby not interfering with uranium elution peak. Different eluents and parameters like pH, concentration of eluent are studied for the purpose. The spiking standard recovery was found to be more than 90 %. The developed method has been compared with other techniques and found to be in agreement.
测量铀提取设施工艺流溶液中铀含量的反相液相色谱法
本文介绍了一种利用 C18 色谱柱、α-羟基异丁烯酸和甲醇的混合物作为洗脱剂和流动分光光度计检测器的反相液相色谱法测定铀工艺流溶液中铀含量的简单方法。这种方法的优点是稀土元素等干扰元素不会保留在色谱柱上,而是在溶剂峰附近洗脱,因此不会干扰铀的洗脱峰。为此研究了不同的洗脱剂和参数,如 pH 值、洗脱剂浓度等。发现加标标准回收率超过 90%。将所开发的方法与其他技术进行了比较,结果表明两者是一致的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Radiochimica Acta
Radiochimica Acta 化学-核科学技术
CiteScore
2.90
自引率
16.70%
发文量
78
审稿时长
6 months
期刊介绍: Radiochimica Acta publishes manuscripts encompassing chemical aspects of nuclear science and technology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信