Borja Salvador-Culla, Ahmmed Afsara, Nicola Roper, Julie Mulroy, Lubomira Galankova, Holly Duncan, David Tabibian, Jose Lamarca-Mateu, Francisco C Figueiredo
{"title":"Accelerated Corneal Crosslinking to Arrest Progression of Corneal Ectasia: A Prospective Multicenter Study.","authors":"Borja Salvador-Culla, Ahmmed Afsara, Nicola Roper, Julie Mulroy, Lubomira Galankova, Holly Duncan, David Tabibian, Jose Lamarca-Mateu, Francisco C Figueiredo","doi":"10.1097/ICL.0000000000001065","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To report the results of epithelium-off accelerated corneal collagen crosslinking (accelerated corneal crosslinking [ACXL]) in patients with progressive keratoconus.</p><p><strong>Methods: </strong>This prospective, nonrandomized, noncomparative, interventional, multicenter clinical study included all patients who underwent ACXL, either continuous (c-ACXL; 9 mW/cm 2 , 10', 5.4 J/cm 2 ) or pulsed (p-ACXL; 2″ON/1″OFF, 30 mW/cm 2 , 4.5', 5.4 J/cm 2 ) between January 2014 and May 2017. Best-corrected visual acuity, sphere, cylinder, spherical equivalent, and topographical keratometry data were collected preoperatively and at 1, 3, 6, 12, 18, and 24 months postoperatively.</p><p><strong>Results: </strong>Ninety-six eyes of 78 patients were included. The mean age was 20.8±4.4 years (14-33) for c-ACXL and 26.7±7.7 years (12-37) for p-ACXL. The mean best-corrected visual acuity was 0.4±0.4 for c-ACXL and 0.01±0.1 for p-ACXL preoperatively, and 0.3±0.3 ( P =0.0014) and -0.01±0.1 ( P =0.1554), respectively, at the last follow-up. The subjective sphere and spherical equivalent did not show statistically significant differences between the time points ( P >0.05). The subjective cylinder showed significant differences ( P =0.0013 for c-ACXL; P =0.0358 for p-ACXL). Keratometric values (K steep , K flat , and SimK) remained stable, with no statistically significant differences ( P >0.05). No major complications were noted.</p><p><strong>Conclusions: </strong>Both c-ACXL and p-ACXL are equally safe and effective ACXL protocols in stabilizing the progression of keratoconus and can be considered alternatives to the conventional Dresden protocol.</p>","PeriodicalId":50457,"journal":{"name":"Eye & Contact Lens-Science and Clinical Practice","volume":" ","pages":"126-131"},"PeriodicalIF":2.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye & Contact Lens-Science and Clinical Practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ICL.0000000000001065","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/7 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: To report the results of epithelium-off accelerated corneal collagen crosslinking (accelerated corneal crosslinking [ACXL]) in patients with progressive keratoconus.
Methods: This prospective, nonrandomized, noncomparative, interventional, multicenter clinical study included all patients who underwent ACXL, either continuous (c-ACXL; 9 mW/cm 2 , 10', 5.4 J/cm 2 ) or pulsed (p-ACXL; 2″ON/1″OFF, 30 mW/cm 2 , 4.5', 5.4 J/cm 2 ) between January 2014 and May 2017. Best-corrected visual acuity, sphere, cylinder, spherical equivalent, and topographical keratometry data were collected preoperatively and at 1, 3, 6, 12, 18, and 24 months postoperatively.
Results: Ninety-six eyes of 78 patients were included. The mean age was 20.8±4.4 years (14-33) for c-ACXL and 26.7±7.7 years (12-37) for p-ACXL. The mean best-corrected visual acuity was 0.4±0.4 for c-ACXL and 0.01±0.1 for p-ACXL preoperatively, and 0.3±0.3 ( P =0.0014) and -0.01±0.1 ( P =0.1554), respectively, at the last follow-up. The subjective sphere and spherical equivalent did not show statistically significant differences between the time points ( P >0.05). The subjective cylinder showed significant differences ( P =0.0013 for c-ACXL; P =0.0358 for p-ACXL). Keratometric values (K steep , K flat , and SimK) remained stable, with no statistically significant differences ( P >0.05). No major complications were noted.
Conclusions: Both c-ACXL and p-ACXL are equally safe and effective ACXL protocols in stabilizing the progression of keratoconus and can be considered alternatives to the conventional Dresden protocol.
期刊介绍:
Eye & Contact Lens: Science and Clinical Practice is the official journal of the Contact Lens Association of Ophthalmologists (CLAO), an international educational association for anterior segment research and clinical practice of interest to ophthalmologists, optometrists, and other vision care providers and researchers. Focusing especially on contact lenses, it also covers dry eye disease, MGD, infections, toxicity of drops and contact lens care solutions, topography, cornea surgery and post-operative care, optics, refractive surgery and corneal stability (eg, UV cross-linking). Peer-reviewed and published six times annually, it is a highly respected scientific journal in its field.