Adsorption Mass Transfer Zone of Vancomycin in Cartridges With Styrene-Divinylbenzene Sorbent.

IF 3.1 3区 医学 Q2 ENGINEERING, BIOMEDICAL
ASAIO Journal Pub Date : 2024-08-01 Epub Date: 2024-02-12 DOI:10.1097/MAT.0000000000002166
Thiago Reis, Claudio Ronco, Gonzalo Ramírez-Guerrero, Matteo Marcello, Massimo de Cal, Francisco A R Neves, Anna Lorenzin
{"title":"Adsorption Mass Transfer Zone of Vancomycin in Cartridges With Styrene-Divinylbenzene Sorbent.","authors":"Thiago Reis, Claudio Ronco, Gonzalo Ramírez-Guerrero, Matteo Marcello, Massimo de Cal, Francisco A R Neves, Anna Lorenzin","doi":"10.1097/MAT.0000000000002166","DOIUrl":null,"url":null,"abstract":"<p><p>Cartridges for hemoadsorption containing styrene-divinylbenzene sorbent are used for multiple conditions, such as intoxication. The mass transfer zone comprises the extension along the longitudinal span of the cartridge where adsorption occurs. The aim of this experiment is to evaluate the mass transfer zone for vancomycin in the HA380 cartridge. The experiment was carried out twice. A saline solution with vancomycin passed through a HA380-modified cartridge at 100 ml/min in a single-pass fashion. The cartridge had four openings along its longitudinal dimension, at 3, 6, 9, and 12 cm. In both experiments, the collection of aliquots occurred at minute 4, in the four openings and pre- and post-cartridge, and an additional sample from the effluent bag at the end of each experiment. In the second experiment, an additional sampling of the same six sites occurred at minute 14. The sigmoidal shape of the curve for the mass transfer zone of vancomycin was similar to the theoretical one. In experiment one, at minute 4, vancomycin clearance was 98.75 ml/min. In experiment two, vancomycin clearance at minutes 4 and 14 was 93.76 and 93.20 ml/min, respectively. This implies an adequate and optimal design of the HA380 cartridge.</p>","PeriodicalId":8844,"journal":{"name":"ASAIO Journal","volume":" ","pages":"714-718"},"PeriodicalIF":3.1000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11280445/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASAIO Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1097/MAT.0000000000002166","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/12 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Cartridges for hemoadsorption containing styrene-divinylbenzene sorbent are used for multiple conditions, such as intoxication. The mass transfer zone comprises the extension along the longitudinal span of the cartridge where adsorption occurs. The aim of this experiment is to evaluate the mass transfer zone for vancomycin in the HA380 cartridge. The experiment was carried out twice. A saline solution with vancomycin passed through a HA380-modified cartridge at 100 ml/min in a single-pass fashion. The cartridge had four openings along its longitudinal dimension, at 3, 6, 9, and 12 cm. In both experiments, the collection of aliquots occurred at minute 4, in the four openings and pre- and post-cartridge, and an additional sample from the effluent bag at the end of each experiment. In the second experiment, an additional sampling of the same six sites occurred at minute 14. The sigmoidal shape of the curve for the mass transfer zone of vancomycin was similar to the theoretical one. In experiment one, at minute 4, vancomycin clearance was 98.75 ml/min. In experiment two, vancomycin clearance at minutes 4 and 14 was 93.76 and 93.20 ml/min, respectively. This implies an adequate and optimal design of the HA380 cartridge.

苯乙烯-二乙烯基苯吸附剂滤芯中万古霉素的吸附传质区。
含有苯乙烯-二乙烯基苯吸附剂的血吸附筒可用于多种情况,如中毒。传质区包括沿吸附筒纵向延伸的部分。本实验旨在评估 HA380 滤芯中万古霉素的传质区。实验进行了两次。含有万古霉素的生理盐水以 100 毫升/分钟的速度单次通过 HA380 改良滤芯。滤芯沿纵向有四个开口,分别位于 3、6、9 和 12 厘米处。在两次实验中,都是在第 4 分钟在四个开口处和滤芯前后收集等分样品,并在每次实验结束时从出水袋中收集额外的样品。在第二次实验中,在第 14 分钟对同样的六个点进行了额外采样。万古霉素传质区的曲线形状与理论曲线相似。在实验一中,第 4 分钟时万古霉素的清除率为 98.75 毫升/分钟。在实验二中,万古霉素在第 4 分钟和第 14 分钟的清除率分别为 93.76 毫升/分钟和 93.20 毫升/分钟。这意味着 HA380 滤芯的设计是适当和优化的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
ASAIO Journal
ASAIO Journal 医学-工程:生物医学
CiteScore
6.60
自引率
7.10%
发文量
651
审稿时长
4-8 weeks
期刊介绍: ASAIO Journal is in the forefront of artificial organ research and development. On the cutting edge of innovative technology, it features peer-reviewed articles of the highest quality that describe research, development, the most recent advances in the design of artificial organ devices and findings from initial testing. Bimonthly, the ASAIO Journal features state-of-the-art investigations, laboratory and clinical trials, and discussions and opinions from experts around the world. The official publication of the American Society for Artificial Internal Organs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信