Study on Outcome of Phacoemulsification Cataract Surgery with Clear Corneal Steep Axis Incision

Mohammad Hussain Raihan, Farah Hossaini Kabir, Kamrul Hasan Khan, Natasha Kajmina, A. R. Hasan, Mohammad Mahbubul Hasan
{"title":"Study on Outcome of Phacoemulsification Cataract Surgery with Clear Corneal Steep Axis Incision","authors":"Mohammad Hussain Raihan, Farah Hossaini Kabir, Kamrul Hasan Khan, Natasha Kajmina, A. R. Hasan, Mohammad Mahbubul Hasan","doi":"10.3329/cbmj.v13i1.71073","DOIUrl":null,"url":null,"abstract":"A prospective, observational study was conducted in the Department of Ophthalmology, Combined Military Hospital (CMH), Dhaka, Bangladesh, from April to October of 2019, to observe the outcome and determine the amount of surgically induced astigmatism in phacoemulsification cataract surgery done with clear corneal incision. A total of 60 patients were included in this study. Cataract extraction was done in all the patients by phacoemulsification through clear corneal incision with foldable intraocular lens implantation. All the surgeries were done with INTREPID Micro-Coaxial system using the INFINITI Vision system by the same surgeon under local anaesthesia. The patients were followed up on 1st, 7th, and 30th POD. The parameters recorded were uncorrected visual acuity, best-corrected visual acuity, slit lamp examination, and keratometry. Due to clear corneal incision on steep axis, the steep meridian became flat, from 44.329±1.473D (diopter) (as found in pre-operative keratometry) to 43.971±1.431D (on the 30th post-operative day). On the other hand, the flat meridian became steeper from 43.225±1.471D (pre-operative) to 43.225±1.501D (on the 30th day). At preoperative examination and 30th day follow-up visit, astigmatism was determined as 1.10±0.319 and 0.583±0.413 respectively. The change of astigmatism was statistically significant (P<0.05).  \nCBMJ 2024 January: vol. 13 no. 01 P: 41-45","PeriodicalId":10576,"journal":{"name":"Community Based Medical Journal","volume":"66 7","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Community Based Medical Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3329/cbmj.v13i1.71073","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A prospective, observational study was conducted in the Department of Ophthalmology, Combined Military Hospital (CMH), Dhaka, Bangladesh, from April to October of 2019, to observe the outcome and determine the amount of surgically induced astigmatism in phacoemulsification cataract surgery done with clear corneal incision. A total of 60 patients were included in this study. Cataract extraction was done in all the patients by phacoemulsification through clear corneal incision with foldable intraocular lens implantation. All the surgeries were done with INTREPID Micro-Coaxial system using the INFINITI Vision system by the same surgeon under local anaesthesia. The patients were followed up on 1st, 7th, and 30th POD. The parameters recorded were uncorrected visual acuity, best-corrected visual acuity, slit lamp examination, and keratometry. Due to clear corneal incision on steep axis, the steep meridian became flat, from 44.329±1.473D (diopter) (as found in pre-operative keratometry) to 43.971±1.431D (on the 30th post-operative day). On the other hand, the flat meridian became steeper from 43.225±1.471D (pre-operative) to 43.225±1.501D (on the 30th day). At preoperative examination and 30th day follow-up visit, astigmatism was determined as 1.10±0.319 and 0.583±0.413 respectively. The change of astigmatism was statistically significant (P<0.05).   CBMJ 2024 January: vol. 13 no. 01 P: 41-45
透明角膜陡轴切口超声乳化白内障手术效果研究
2019年4月至10月,孟加拉国达卡联合军事医院(CMH)眼科开展了一项前瞻性观察研究,旨在观察透明角膜切口白内障超声乳化手术的结果并确定手术诱发散光的程度。本研究共纳入了 60 名患者。所有患者均通过透明角膜切口进行超声乳化白内障摘除术,并植入折叠式眼内透镜。所有手术均采用 INFINITI Vision 系统的 INTREPID 微型同轴系统,由同一外科医生在局部麻醉下完成。在第 1、7 和 30 个 POD 日对患者进行了随访。记录的参数包括未矫正视力、最佳矫正视力、裂隙灯检查和角膜测量。由于在陡轴上进行了清晰的角膜切口,陡子午线变得平坦,从 44.329±1.473D(屈光度)(术前角膜度数)降至 43.971±1.431D(术后第 30 天)。另一方面,平经从 43.225±1.471D(术前)变为 43.225±1.501D(术后第 30 天)。术前检查和第 30 天随访时,散光度数分别为 1.10±0.319 和 0.583±0.413。散光的变化具有统计学意义(P<0.05)。 CBMJ 2024 年 1 月:第 13 卷第 01 期 P: 41-45
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信