Direct immunofluorescence on formalin-fixed, paraffin-embedded versus fresh frozen human renal biopsies: a comparative study.

Q2 Health Professions
Ali J Eidan
{"title":"Direct immunofluorescence on formalin-fixed, paraffin-embedded versus fresh frozen human renal biopsies: a comparative study.","authors":"Ali J Eidan","doi":"10.1080/15321819.2024.2306324","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The data referring to the value of direct immunofluorescence on formalin-fixed, paraffin-embedded tissue (IF-Paraffin) in the diagnosis of renal diseases is controversial. The aim of this study was to investigate whether renal biopsies evaluated by routine immunofluorescence on frozen tissue (IF-Frozen) would yield adequate findings to confirm diagnoses when the IF-Paraffin technique was applied.</p><p><strong>Methods: </strong>To show immunoglobulins, complement components, and light chains, 55 native renal biopsies were subjected to IF-Paraffin and IF-Frozen staining techniques. The intensity of the staining was compared, and the sensitivity and specificity were calculated.</p><p><strong>Results: </strong>The IF-Paraffin technique showed a sensitivity of 89%, 81%, 86%, 30%, 71%, 60%, and 77% for IgG, IgM, IgA, C1q, C3, κ, and λ, respectively, whereas specificity was 91%, 100%, 100%, 96%, 94%, 98%, and 100%. It showed diagnostic findings in 87% of cases. Compared to cases that had both IF-Paraffin and IF-Frozen staining techniques, 43 of 55 showed either equal intensity for the diagnostic immunoglobulin/complement or a little difference.</p><p><strong>Conclusions: </strong>Direct immunofluorescence on formalin-fixed, paraffin-embedded sections cannot replace immunofluorescence on frozen sections in the assessment of renal biopsies, but may be a \"salvage technique\" when frozen tissue is insufficient or unavailable and must be interpreted with great caution.</p>","PeriodicalId":15990,"journal":{"name":"Journal of immunoassay & immunochemistry","volume":" ","pages":"292-305"},"PeriodicalIF":0.0000,"publicationDate":"2024-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of immunoassay & immunochemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/15321819.2024.2306324","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/23 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The data referring to the value of direct immunofluorescence on formalin-fixed, paraffin-embedded tissue (IF-Paraffin) in the diagnosis of renal diseases is controversial. The aim of this study was to investigate whether renal biopsies evaluated by routine immunofluorescence on frozen tissue (IF-Frozen) would yield adequate findings to confirm diagnoses when the IF-Paraffin technique was applied.

Methods: To show immunoglobulins, complement components, and light chains, 55 native renal biopsies were subjected to IF-Paraffin and IF-Frozen staining techniques. The intensity of the staining was compared, and the sensitivity and specificity were calculated.

Results: The IF-Paraffin technique showed a sensitivity of 89%, 81%, 86%, 30%, 71%, 60%, and 77% for IgG, IgM, IgA, C1q, C3, κ, and λ, respectively, whereas specificity was 91%, 100%, 100%, 96%, 94%, 98%, and 100%. It showed diagnostic findings in 87% of cases. Compared to cases that had both IF-Paraffin and IF-Frozen staining techniques, 43 of 55 showed either equal intensity for the diagnostic immunoglobulin/complement or a little difference.

Conclusions: Direct immunofluorescence on formalin-fixed, paraffin-embedded sections cannot replace immunofluorescence on frozen sections in the assessment of renal biopsies, but may be a "salvage technique" when frozen tissue is insufficient or unavailable and must be interpreted with great caution.

福尔马林固定、石蜡包埋与新鲜冷冻人肾活检组织的直接免疫荧光:一项比较研究。
背景:有关福尔马林固定石蜡包埋组织(IF-Paraffin)直接免疫荧光在肾脏疾病诊断中的价值的数据尚存在争议。本研究的目的是探讨在应用 IF-石蜡技术时,通过对冷冻组织(IF-Frozen)进行常规免疫荧光评估肾活检是否能获得足够的结果来确诊:为了显示免疫球蛋白、补体成分和轻链,对 55 例原生肾活检组织采用了 IF-巴拉芬和 IF 冷冻染色技术。对染色强度进行了比较,并计算了敏感性和特异性:IF-石蜡技术对 IgG、IgM、IgA、C1q、C3、κ 和 λ 的敏感性分别为 89%、81%、86%、30%、71%、60% 和 77%,而特异性分别为 91%、100%、100%、96%、94%、98% 和 100%。87%的病例都有诊断结果。与同时采用 IF-石蜡和 IF-冰冻染色技术的病例相比,55 例病例中有 43 例显示诊断性免疫球蛋白/补体的强度相同或差别不大:福尔马林固定、石蜡包埋切片上的直接免疫荧光不能取代冷冻切片上的免疫荧光来评估肾活检组织,但在冷冻组织不足或不可用时可作为一种 "挽救技术",必须非常谨慎地进行解释。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.50
自引率
0.00%
发文量
38
审稿时长
>12 weeks
期刊介绍: The Journal of Immunoassay & Immunochemistry is an international forum for rapid dissemination of research results and methodologies dealing with all aspects of immunoassay and immunochemistry, as well as selected aspects of immunology. They include receptor assay, enzyme-linked immunosorbent assay (ELISA) in all of its embodiments, ligand-based assays, biological markers of ligand-receptor interaction, in vivo and in vitro diagnostic reagents and techniques, diagnosis of AIDS, point-of-care testing, clinical immunology, antibody isolation and purification, and others.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信