The Repeatability of Axial Length Measurements Using a Scheimpflug-based System.

IF 1.6 Q3 OPHTHALMOLOGY
Journal of Ophthalmic & Vision Research Pub Date : 2023-11-30 eCollection Date: 2023-10-01 DOI:10.18502/jovr.v18i4.14551
Sara Sardari, Mehdi Khabazkhoob, Ebrahim Jafarzadehpur, Akbar Fotouhi
{"title":"The Repeatability of Axial Length Measurements Using a Scheimpflug-based System.","authors":"Sara Sardari, Mehdi Khabazkhoob, Ebrahim Jafarzadehpur, Akbar Fotouhi","doi":"10.18502/jovr.v18i4.14551","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the repeatability of Pentacam AXL as a Scheimpflug-based system or measuring axial length according to the age, sex, lens type, axial length value, and type of cataract.</p><p><strong>Methods: </strong>The present study was conducted using multistage cluster sampling in Tehran, Iran. Ocular biometry was performed, using the Pentacam AXL, by an experienced optometrist on all the participants. The axial length (AL) measurements were taken thrice, with a gap of 10 minutes. To evaluate the repeatability, the intraclass correlation coefficient (ICC) and the repeatability coefficient (RC) were calculated. To determine the significant difference in the repeatability index among study variables, the tolerance index (TI) was calculated.</p><p><strong>Results: </strong>In this report, 897 eyes of 677 individuals aged between 20 and 91 years (mean <math><mo>±</mo></math> SD: 64.90 <math><mo>±</mo></math> 13.62 years) were reported. The ICC of the axial length measurements was 0.981 for all cases. Based on the within-subject standard deviation, the RC was 0.401. The ICC was 0.976 and 0.985 in men and women, respectively. The TI showed better RC of measurements among females. The ICC decreased from 0.999 in participants under 40 years to 0.973 in individuals over 60 years of age. The TI showed a decrease in RC with advancing age. The RC was worse in eyes with nuclear cataracts; the RC was also worse in the first quartile of the signal-to-noise ratio (SNR) compared to the other SNR quartiles.</p><p><strong>Conclusion: </strong>The Scheimpflug-based systemPentacam AXL had high repeatability in measuring axial length. Some variables such as male gender, older age, and nuclear cataract were associated with reduced repeatability of the measurements. A higher SNR was associated with better repeatability of the axial length measurements.</p>","PeriodicalId":16586,"journal":{"name":"Journal of Ophthalmic & Vision Research","volume":"18 4","pages":"396-404"},"PeriodicalIF":1.6000,"publicationDate":"2023-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10794809/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ophthalmic & Vision Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18502/jovr.v18i4.14551","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To assess the repeatability of Pentacam AXL as a Scheimpflug-based system or measuring axial length according to the age, sex, lens type, axial length value, and type of cataract.

Methods: The present study was conducted using multistage cluster sampling in Tehran, Iran. Ocular biometry was performed, using the Pentacam AXL, by an experienced optometrist on all the participants. The axial length (AL) measurements were taken thrice, with a gap of 10 minutes. To evaluate the repeatability, the intraclass correlation coefficient (ICC) and the repeatability coefficient (RC) were calculated. To determine the significant difference in the repeatability index among study variables, the tolerance index (TI) was calculated.

Results: In this report, 897 eyes of 677 individuals aged between 20 and 91 years (mean ± SD: 64.90 ± 13.62 years) were reported. The ICC of the axial length measurements was 0.981 for all cases. Based on the within-subject standard deviation, the RC was 0.401. The ICC was 0.976 and 0.985 in men and women, respectively. The TI showed better RC of measurements among females. The ICC decreased from 0.999 in participants under 40 years to 0.973 in individuals over 60 years of age. The TI showed a decrease in RC with advancing age. The RC was worse in eyes with nuclear cataracts; the RC was also worse in the first quartile of the signal-to-noise ratio (SNR) compared to the other SNR quartiles.

Conclusion: The Scheimpflug-based systemPentacam AXL had high repeatability in measuring axial length. Some variables such as male gender, older age, and nuclear cataract were associated with reduced repeatability of the measurements. A higher SNR was associated with better repeatability of the axial length measurements.

使用基于 Scheimpflug 的系统测量轴向长度的重复性。
目的:根据年龄、性别、晶状体类型、轴向长度值和白内障类型,评估 Pentacam AXL 作为基于 Scheimpflug 的系统或测量轴向长度的重复性:本研究在伊朗德黑兰采用多阶段群组抽样法进行。由一名经验丰富的验光师使用 Pentacam AXL 对所有参与者进行眼部生物测量。轴长(AL)测量共进行了三次,每次间隔 10 分钟。为了评估重复性,计算了类内相关系数(ICC)和重复性系数(RC)。为确定研究变量间重复性指数的显著差异,计算了容差指数(TI):本报告共报告了 677 名年龄在 20 至 91 岁之间(平均 ± SD:64.90 ± 13.62 岁)的患者的 897 只眼睛。所有病例轴长测量的 ICC 均为 0.981。根据受试者内标准偏差,RC 为 0.401。男性和女性的 ICC 分别为 0.976 和 0.985。TI显示女性的测量RC更好。在 40 岁以下的参与者中,ICC 从 0.999 降至 60 岁以上的 0.973。随着年龄的增长,TI 的 RC 值也在下降。患有核性白内障的眼睛的 RC 更差;与其他信噪比四分位数相比,信噪比第一四分位数的 RC 也更差:结论:基于Scheimpflug的Pentacam AXL系统在测量轴长方面具有很高的重复性。男性、高龄和核性白内障等变量与测量重复性降低有关。信噪比越高,轴长测量的重复性越好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.60
自引率
0.00%
发文量
63
审稿时长
30 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信