Ashley E Milkovits, David Sugrue, Janie Faris, Jessica L Schad, Kelly B McAllister
{"title":"Hemostatic Efficacy and Safety of Weight-Based Versus Fixed-Dose 4F-PCC for Vitamin K Antagonist Reversal.","authors":"Ashley E Milkovits, David Sugrue, Janie Faris, Jessica L Schad, Kelly B McAllister","doi":"10.1177/08971900241228779","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Four-factor prothrombin complex concentrate (4F-PCC) is indicated for vitamin K antagonist (VKA) reversal but is associated with thrombotic events (TE). In 2018, the institution revised 4F-PCC dosing for VKA reversal from INR and weight-based dosing to a fixed-dose of 1500 units. <b>Objective:</b> The purpose of this study was to compare hemostatic efficacy and TE rate of fixed-dose 4PCC to weight-based dosing. <b>Methods:</b> This was a retrospective, single-center, quasi-experimental study of adult patients who received 4F-PCC for VKA reversal from January 2014 through May 2016 (INR and weight-based dosing) or April through October 2018 (fixed-dosing). The primary endpoint was hemostatic efficacy, defined by achieving an INR of ≤1.4, or an INR of ≤1.7 with evidence of hemostasis. The key secondary endpoint was TE within 14 days of 4F-PCC administration. Data were analyzed using descriptive statistics, chi-squared for nominal data and Mann-Whitney U for ordinal and continuous data. <b>Results:</b> The study included 163 patients who received weight-based dosing and 45 who received fixed-dose 4F-PCC. Hemostatic efficacy was 76.9% of patients in the weight-based group and 77.4% of patients in the fixed-dose group (<i>P</i> = .229). TE occurred in 13.5% of the weight-based vs 6.7% of the fixed-dose group (<i>P</i> = .181). <b>Conclusion:</b> This study found no difference in hemostatic efficacy with fixed-dose 4F-PCC for VKA reversal compared to INR and weight-based dosing. The occurrence of TE was reduced by 50% with the 4F-PCC fixed-dose strategy; however, this difference was not statistically significant. Further randomized studies are needed to confirm these results.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/08971900241228779","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/19 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Four-factor prothrombin complex concentrate (4F-PCC) is indicated for vitamin K antagonist (VKA) reversal but is associated with thrombotic events (TE). In 2018, the institution revised 4F-PCC dosing for VKA reversal from INR and weight-based dosing to a fixed-dose of 1500 units. Objective: The purpose of this study was to compare hemostatic efficacy and TE rate of fixed-dose 4PCC to weight-based dosing. Methods: This was a retrospective, single-center, quasi-experimental study of adult patients who received 4F-PCC for VKA reversal from January 2014 through May 2016 (INR and weight-based dosing) or April through October 2018 (fixed-dosing). The primary endpoint was hemostatic efficacy, defined by achieving an INR of ≤1.4, or an INR of ≤1.7 with evidence of hemostasis. The key secondary endpoint was TE within 14 days of 4F-PCC administration. Data were analyzed using descriptive statistics, chi-squared for nominal data and Mann-Whitney U for ordinal and continuous data. Results: The study included 163 patients who received weight-based dosing and 45 who received fixed-dose 4F-PCC. Hemostatic efficacy was 76.9% of patients in the weight-based group and 77.4% of patients in the fixed-dose group (P = .229). TE occurred in 13.5% of the weight-based vs 6.7% of the fixed-dose group (P = .181). Conclusion: This study found no difference in hemostatic efficacy with fixed-dose 4F-PCC for VKA reversal compared to INR and weight-based dosing. The occurrence of TE was reduced by 50% with the 4F-PCC fixed-dose strategy; however, this difference was not statistically significant. Further randomized studies are needed to confirm these results.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.