A review of the experimental methods and results of testing the mechanical properties of Tunica Albuginea.

Q3 Engineering
Jaymes Schmidt, Dylan Goode, Ryan Flannigan, Hadi Mohammadi
{"title":"A review of the experimental methods and results of testing the mechanical properties of Tunica Albuginea.","authors":"Jaymes Schmidt, Dylan Goode, Ryan Flannigan, Hadi Mohammadi","doi":"10.1080/03091902.2023.2300829","DOIUrl":null,"url":null,"abstract":"<p><p>The present work provides a comprehensive review of the literature on the mechanical properties and existing human tunica albuginea tissue testing methods. Assessments were completed on papers reporting experimental values of Young's modulus, tensile strength, puncture strength, stiffness, toughness, and strain at the ultimate tensile strength (UTS). A high degree of variability in the reported experimental values was found; Young's modulus ranged from 5 MPa to 118 MPa, and tensile strength went from 1.1 MPa to 6.1 MPa. A comparison of the variability of the reported experimental values for puncture strength, stiffness, toughness, and strain at the UTS could not be completed due to a lack of experimental results. This review discusses the pathophysiology and surgical treatment of erectile dysfunction and Peyronie's disease, variability in the existing reported mechanical properties, the impact of the variability of mechanical properties on in silico models and explores the absence of a standardised testing method as a possible reason for the variable in results. Finally, this work attempts to provide suggestions for standardising future mechanical testing of the tunica albuginea through minimising and reporting freeze/thaw cycling, noting the proximal/distal region of the cadaver tunica sample, reporting the orientation (o'clock position) of the cadaver tunica sample, and testing the cadaver tunica samples in bi-axial tension. Ultimately, standardising the testing methodologies of the tunica albuginea will provide higher confidence in reported mechanical property values.</p>","PeriodicalId":39637,"journal":{"name":"Journal of Medical Engineering and Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Engineering and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/03091902.2023.2300829","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/22 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

The present work provides a comprehensive review of the literature on the mechanical properties and existing human tunica albuginea tissue testing methods. Assessments were completed on papers reporting experimental values of Young's modulus, tensile strength, puncture strength, stiffness, toughness, and strain at the ultimate tensile strength (UTS). A high degree of variability in the reported experimental values was found; Young's modulus ranged from 5 MPa to 118 MPa, and tensile strength went from 1.1 MPa to 6.1 MPa. A comparison of the variability of the reported experimental values for puncture strength, stiffness, toughness, and strain at the UTS could not be completed due to a lack of experimental results. This review discusses the pathophysiology and surgical treatment of erectile dysfunction and Peyronie's disease, variability in the existing reported mechanical properties, the impact of the variability of mechanical properties on in silico models and explores the absence of a standardised testing method as a possible reason for the variable in results. Finally, this work attempts to provide suggestions for standardising future mechanical testing of the tunica albuginea through minimising and reporting freeze/thaw cycling, noting the proximal/distal region of the cadaver tunica sample, reporting the orientation (o'clock position) of the cadaver tunica sample, and testing the cadaver tunica samples in bi-axial tension. Ultimately, standardising the testing methodologies of the tunica albuginea will provide higher confidence in reported mechanical property values.

测试豚骨机械特性的实验方法和结果综述。
本研究全面回顾了有关人体白膜组织机械性能和现有测试方法的文献。对报告杨氏模量、拉伸强度、穿刺强度、刚度、韧性和极限拉伸强度(UTS)应变实验值的论文进行了评估。结果发现,报告的实验值存在很大差异;杨氏模量从 5 兆帕到 118 兆帕不等,抗拉强度从 1.1 兆帕到 6.1 兆帕不等。由于缺乏实验结果,无法完成对所报告的穿刺强度、刚度、韧性和 UTS 应变的实验值的可变性比较。本综述讨论了勃起功能障碍和佩罗尼氏病的病理生理学和手术治疗、现有报告中机械性能的可变性、机械性能的可变性对硅学模型的影响,并探讨了缺乏标准化测试方法作为结果可变性的可能原因。最后,这项研究试图通过尽量减少和报告冷冻/解冻循环、注意尸体韧带样本的近端/远端区域、报告尸体韧带样本的方向(点钟位置)以及在双轴拉力下测试尸体韧带样本,为将来的韧带机械测试标准化提供建议。最终,韧带测试方法的标准化将为报告的机械属性值提供更高的可信度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Medical Engineering and Technology
Journal of Medical Engineering and Technology Engineering-Biomedical Engineering
CiteScore
4.60
自引率
0.00%
发文量
77
期刊介绍: The Journal of Medical Engineering & Technology is an international, independent, multidisciplinary, bimonthly journal promoting an understanding of the physiological processes underlying disease processes and the appropriate application of technology. Features include authoritative review papers, the reporting of original research, and evaluation reports on new and existing techniques and devices. Each issue of the journal contains a comprehensive information service which provides news relevant to the world of medical technology, details of new products, book reviews, and selected contents of related journals.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信