Comparison of skin dose in IMRT and VMAT with TrueBeam and Halcyon linear accelerator for whole breast irradiation.

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS
ACS Applied Bio Materials Pub Date : 2024-06-01 Epub Date: 2024-01-15 DOI:10.1007/s13246-023-01373-x
Jae Hyun Seok, So Hyun Ahn, Woo Sang Ahn, Dong Hyeok Choi, Seong Soo Shin, Wonsik Choi, In-Hye Jung, Rena Lee, Jin Sung Kim
{"title":"Comparison of skin dose in IMRT and VMAT with TrueBeam and Halcyon linear accelerator for whole breast irradiation.","authors":"Jae Hyun Seok, So Hyun Ahn, Woo Sang Ahn, Dong Hyeok Choi, Seong Soo Shin, Wonsik Choi, In-Hye Jung, Rena Lee, Jin Sung Kim","doi":"10.1007/s13246-023-01373-x","DOIUrl":null,"url":null,"abstract":"<p><p>With the increasing use of flattening filter free (FFF) beams, it is important to evaluate the impact on the skin dose and target coverage of breast cancer treatments. This study aimed to compare skin doses of treatments using FFF and flattening filter (FF) beams for breast cancer. The study established treatment plans for left breast of an anthropomorphic phantom using Halcyon's 6-MV FFF beam and TrueBeam's 6-MV FF beam. Volumetric modulated arc therapy (VMAT) with varying numbers of arcs and intensity modulated radiation therapy (IMRT) were employed, and skin doses were measured at five points using Gafchromic EBT3 film. Each measurement was repeated three times, and averaged to reduce uncertainty. All plans were compared in terms of plan quality to ensure homogeneous target coverage. The study found that when using VMAT with two, four, and six arcs, in-field doses were 19%, 15%, and 6% higher, respectively, when using Halcyon compared to TrueBeam. Additionally, when using two arcs for VMAT, in-field doses were 10% and 15% higher compared to four and six arcs when using Halcyon. Finally, in-field dose from Halcyon using IMRT was about 1% higher than when using TrueBeam. Our research confirmed that when treating breast cancer with FFF beams, skin dose is higher than with traditional FF beams. Moreover, number of arcs used in VMAT treatment with FFF beams affects skin dose to the patient. To maintain a skin dose similar to that of FF beams when using Halcyon, it may be worth considering increasing the number of arcs.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11166860/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s13246-023-01373-x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/15 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

With the increasing use of flattening filter free (FFF) beams, it is important to evaluate the impact on the skin dose and target coverage of breast cancer treatments. This study aimed to compare skin doses of treatments using FFF and flattening filter (FF) beams for breast cancer. The study established treatment plans for left breast of an anthropomorphic phantom using Halcyon's 6-MV FFF beam and TrueBeam's 6-MV FF beam. Volumetric modulated arc therapy (VMAT) with varying numbers of arcs and intensity modulated radiation therapy (IMRT) were employed, and skin doses were measured at five points using Gafchromic EBT3 film. Each measurement was repeated three times, and averaged to reduce uncertainty. All plans were compared in terms of plan quality to ensure homogeneous target coverage. The study found that when using VMAT with two, four, and six arcs, in-field doses were 19%, 15%, and 6% higher, respectively, when using Halcyon compared to TrueBeam. Additionally, when using two arcs for VMAT, in-field doses were 10% and 15% higher compared to four and six arcs when using Halcyon. Finally, in-field dose from Halcyon using IMRT was about 1% higher than when using TrueBeam. Our research confirmed that when treating breast cancer with FFF beams, skin dose is higher than with traditional FF beams. Moreover, number of arcs used in VMAT treatment with FFF beams affects skin dose to the patient. To maintain a skin dose similar to that of FF beams when using Halcyon, it may be worth considering increasing the number of arcs.

使用 TrueBeam 和 Halcyon 直线加速器进行全乳腺照射时,IMRT 和 VMAT 皮肤剂量的比较。
随着无扁平化滤波(FFF)光束的使用越来越多,评估其对乳腺癌治疗的皮肤剂量和靶点覆盖的影响非常重要。本研究旨在比较使用无平坦滤波(FFF)光束和平坦滤波(FF)光束治疗乳腺癌的皮肤剂量。研究使用 Halcyon 的 6-MV FFF 光束和 TrueBeam 的 6-MV FF 光束为拟人化模型的左乳房制定了治疗计划。采用了不同弧数的体积调制弧治疗(VMAT)和强度调制放射治疗(IMRT),并使用 Gafchromic EBT3 胶片测量了五个点的皮肤剂量。每次测量重复三次,取平均值以减少不确定性。对所有计划的计划质量进行比较,以确保目标覆盖均匀。研究发现,与 TrueBeam 相比,当使用两个、四个和六个弧的 VMAT 时,Halcyon 的场内剂量分别高出 19%、15% 和 6%。此外,当使用两个弧形 VMAT 时,场内剂量比使用 Halcyon 时的四个弧形和六个弧形分别高 10%和 15%。最后,Halcyon 使用 IMRT 时的场内剂量比使用 TrueBeam 时高约 1%。我们的研究证实,使用 FFF 光束治疗乳腺癌时,皮肤剂量高于传统的 FF 光束。此外,使用 FFF 光束进行 VMAT 治疗时使用的弧数也会影响患者的皮肤剂量。为了在使用 Halcyon 时保持与 FF 光束相似的皮肤剂量,可能值得考虑增加弧线的数量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信