Efficacy of an experimental gaseous ozone-based sterilization method for clear aligners

Fabiana Nicita, Massimo Calapaj, S. Alibrandi, L. Donato, Emidio Aquilio, R. D’Angelo, A. Sidoti
{"title":"Efficacy of an experimental gaseous ozone-based sterilization method for clear aligners","authors":"Fabiana Nicita, Massimo Calapaj, S. Alibrandi, L. Donato, Emidio Aquilio, R. D’Angelo, A. Sidoti","doi":"10.2319/061623-421.1","DOIUrl":null,"url":null,"abstract":"\n \n \n To assess effectiveness of an experimental sterilization method based on the exposure of an O3/O2 gas mixture directly inside the packaging for clear aligners.\n \n \n \n Fifty samples consisting of pieces of polyethylene terephthalate glycol (PET-G) aligners were contaminated by manual handling and subsequently divided into different groups (n = 30 for exposure to O3/O2 gas at different times, n = 10 for positive control with 2% chlorhexidine digluconate, n = 10 for negative control). The measurement of optical densities (OD) of the initial and final microbial cultures was recorded for all groups. Kruskal-Wallis test was used for differences between groups while Wilcoxon test was used to compare initial and final OD values within groups. Statistical significance was set at P < .05.\n \n \n \n Comparison within the groups showed statistically significant differences for exposure to the gaseous mixture (72 hours), for positive and negative controls. Other significant differences were found in the multiple comparisons between the application of gaseous ozone (48 hours and 72 hours) and the negative control.\n \n \n \n The direct exposure of gaseous ozone on the aligners inside their packaging showed microbicidal capacity at 72 hours, which was equivalent to the positive control with immersion in chlorhexidine digluconate. This innovative sterilization procedure could be considered in the final manufacturing processes of clear aligners to eliminate the potentially pathogenic microorganisms that are deposited on surfaces of these orthodontic devices.\n","PeriodicalId":503286,"journal":{"name":"The Angle Orthodontist","volume":"124 9","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Angle Orthodontist","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2319/061623-421.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

To assess effectiveness of an experimental sterilization method based on the exposure of an O3/O2 gas mixture directly inside the packaging for clear aligners. Fifty samples consisting of pieces of polyethylene terephthalate glycol (PET-G) aligners were contaminated by manual handling and subsequently divided into different groups (n = 30 for exposure to O3/O2 gas at different times, n = 10 for positive control with 2% chlorhexidine digluconate, n = 10 for negative control). The measurement of optical densities (OD) of the initial and final microbial cultures was recorded for all groups. Kruskal-Wallis test was used for differences between groups while Wilcoxon test was used to compare initial and final OD values within groups. Statistical significance was set at P < .05. Comparison within the groups showed statistically significant differences for exposure to the gaseous mixture (72 hours), for positive and negative controls. Other significant differences were found in the multiple comparisons between the application of gaseous ozone (48 hours and 72 hours) and the negative control. The direct exposure of gaseous ozone on the aligners inside their packaging showed microbicidal capacity at 72 hours, which was equivalent to the positive control with immersion in chlorhexidine digluconate. This innovative sterilization procedure could be considered in the final manufacturing processes of clear aligners to eliminate the potentially pathogenic microorganisms that are deposited on surfaces of these orthodontic devices.
基于气态臭氧的透明矫治器消毒实验方法的功效
评估直接在透明对准器包装内接触 O3/O2 混合气体的实验性消毒方法的有效性。 手工操作污染了由聚对苯二甲酸乙二醇酯(PET-G)对准器碎片组成的 50 个样品,随后将其分成不同的组(n = 30 在不同时间暴露于 O3/O2 气体,n = 10 用 2% 洗必泰二氯葡萄糖酸盐进行阳性对照,n = 10 进行阴性对照)。记录所有组的初始和最终微生物培养物的光密度(OD)。组间差异采用 Kruskal-Wallis 检验,组内初始和最终 OD 值的比较采用 Wilcoxon 检验。统计显著性以 P < .05 为标准。 组内比较显示,暴露于气态混合物(72 小时)、阳性对照组和阴性对照组的差异具有统计学意义。气态臭氧应用(48 小时和 72 小时)与阴性对照之间的多重比较也发现了其他显着差异。 气态臭氧直接照射包装内的矫治器在72小时后显示出杀菌能力,与浸泡在洗必泰二氯葡萄糖酸盐中的阳性对照组相当。在透明矫治器的最终生产过程中,可以考虑采用这种创新的杀菌程序,以消除沉积在这些矫治器表面的潜在病原微生物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信